Literature DB >> 17517938

Multidetector CT of the paranasal sinus: potential for radiation dose reduction.

Matthias H Brem1, Amir A Zamani, Roberto Riva, Kelly H Zou, Zoran Rumboldt, Friedrich F Hennig, Ron Kikinis, Alexander M Norbash, U Joseph Schoepf.   

Abstract

The aim of the study was to retrospectively determine the potential for radiation dose reduction at multidetector computed tomography (CT) of the paranasal sinus by using computer simulation of the effect of low-radiation dose acquisition on diagnostic image quality. This HIPAA compliant study was approved by the institutional human research committee. The need for informed patient consent was waived. Twenty patients underwent four-section CT at 120 kV, 170 mAs, and 4 x 1-mm collimation. Artificial image noise was added to the CT raw data by using a dedicated software platform. Acquisitions with effective tube currents of 134, 100, 67, and 33 mAs were simulated. Each raw data set was reconstructed with bone and soft-tissue algorithms, and two radiologists independently rated the images in blinded fashion. A two-sided paired Student t test was used for statistical analysis. The lowest radiation dose that still provided diagnostic quality was <or=67 effective mAs for osseous structures and <or=134 effective mAs for the optic nerve and the inferior rectus muscle. On the basis of the results, tube currents can be lowered and radiation dose reduced by 20%. (c) RSNA, 2007.

Entities:  

Mesh:

Year:  2007        PMID: 17517938     DOI: 10.1148/radiol.2433050207

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  23 in total

1.  Data analysis of low dose multislice helical CT scan in orbital trauma.

Authors:  Ji-Wei Wang; Chong Tang; Bo-Rong Pan
Journal:  Int J Ophthalmol       Date:  2012-06-18       Impact factor: 1.779

2.  Low-Dose CT of the Paranasal Sinuses: Minimizing X-Ray Exposure with Spectral Shaping.

Authors:  Wolfgang Wuest; Matthias May; Marc Saake; Michael Brand; Michael Uder; Michael Lell
Journal:  Eur Radiol       Date:  2016-02-24       Impact factor: 5.315

3.  Nasal endoscopy: an adjunct to patient selection for preoperative low-dose CT examination in chronic rhinosinusitis.

Authors:  Marcin Fraczek; Maciej Guzinski; Monika Morawska-Kochman; Kamil H Nelke; Tomasz Krecicki
Journal:  Dentomaxillofac Radiol       Date:  2016-10-17       Impact factor: 2.419

4.  Diagnostic CT radiation and cancer induction.

Authors:  Paula J Richards; Jennifer George
Journal:  Skeletal Radiol       Date:  2010-05       Impact factor: 2.199

5.  Investigation of an optimized scanning protocol for the dentomaxillofacial region using 320-slice multidetector computed tomography.

Authors:  Wei-Chan Lin; Hsueh-Han Wang; Wen-Lin Hsu; Bi-Hui Cao; De-Ji Chen; Chia-Jung Tsai
Journal:  Dentomaxillofac Radiol       Date:  2017-03-07       Impact factor: 2.419

6.  Evaluation of different low-dose multidetector CT and cone beam CT protocols in maxillary sinus imaging: part I-an in vitro study.

Authors:  Abeer A Almashraqi; Eman A Ahmed; Nashwa S Mohamed; Imad H Barngkgei; Nader A Elsherbini; Esam S Halboub
Journal:  Dentomaxillofac Radiol       Date:  2017-04-12       Impact factor: 2.419

7.  Radiation dose reduction in parasinus CT by spectral shaping.

Authors:  Matthias S May; Michael Brand; Michael M Lell; Martin Sedlmair; Thomas Allmendinger; Michael Uder; Wolfgang Wuest
Journal:  Neuroradiology       Date:  2017-01-16       Impact factor: 2.804

8.  Imaging the Parasinus Region with a Third-Generation Dual-Source CT and the Effect of Tin Filtration on Image Quality and Radiation Dose.

Authors:  M M Lell; M S May; M Brand; A Eller; T Buder; E Hofmann; M Uder; W Wuest
Journal:  AJNR Am J Neuroradiol       Date:  2015-03-26       Impact factor: 3.825

9.  Performance of iterative image reconstruction in CT of the paranasal sinuses: a phantom study.

Authors:  B Schulz; M Beeres; B Bodelle; R Bauer; F Al-Butmeh; A Thalhammer; T J Vogl; J M Kerl
Journal:  AJNR Am J Neuroradiol       Date:  2012-12-06       Impact factor: 3.825

10.  Radiation dose reduction in paranasal sinus CT using model-based iterative reconstruction.

Authors:  J M Hoxworth; D Lal; G P Fletcher; A C Patel; M He; R G Paden; A K Hara
Journal:  AJNR Am J Neuroradiol       Date:  2013-10-10       Impact factor: 3.825

View more