Literature DB >> 17505081

Monte Carlo simulations of the dosimetric impact of radiopaque fiducial markers for proton radiotherapy of the prostate.

Wayne Newhauser1, Jonas Fontenot, Nicholas Koch, Lei Dong, Andrew Lee, Yuanshui Zheng, Laurie Waters, Radhe Mohan.   

Abstract

Many clinical studies have demonstrated that implanted radiopaque fiducial markers improve targeting accuracy in external-beam radiotherapy, but little is known about the dose perturbations these markers may cause in patients receiving proton radiotherapy. The objective of this study was to determine what types of implantable markers are visible in setup radiographs and, at the same time, perturb the therapeutic proton dose to the prostate by less than 10%. The radiographic visibility of the markers was assessed by visual inspection of lateral setup radiographs of a pelvic phantom using a kilovoltage x-ray imaging system. The fiducial-induced perturbations in the proton dose were estimated with Monte Carlo simulations. The influence of marker material, size, placement depth and orientation within the pelvis was examined. The radiographic tests confirmed that gold and stainless steel markers were clearly visible and that titanium markers were not. The Monte Carlo simulations revealed that titanium and stainless steel markers minimally perturbed the proton beam, but gold markers cast unacceptably large dose shadows. A 0.9 mm diameter, 3.1 mm long cylindrical stainless steel marker provides good radiographic visibility yet perturbs the proton dose distribution in the prostate by less than 8% when using a parallel opposed lateral beam arrangement.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17505081     DOI: 10.1088/0031-9155/52/11/001

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  26 in total

Review 1.  Technological advances in radiation therapy for prostate cancer.

Authors:  Mehee Choi; Arthur Y Hung
Journal:  Curr Urol Rep       Date:  2010-05       Impact factor: 3.092

Review 2.  Image guidance in proton therapy for lung cancer.

Authors:  Miao Zhang; Wei Zou; Boon-Keng Kevin Teo
Journal:  Transl Lung Cancer Res       Date:  2018-04

3.  Benchmark measurements and simulations of dose perturbations due to metallic spheres in proton beams.

Authors:  Wayne D Newhauser; Laura Rechner; Dragan Mirkovic; Pablo Yepes; Nicholas C Koch; Uwe Titt; Jonas D Fontenot; Rui Zhang
Journal:  Radiat Meas       Date:  2013-11-01       Impact factor: 1.898

Review 4.  Fiducial marker guided prostate radiotherapy: a review.

Authors:  Angela G M O'Neill; Suneil Jain; Alan R Hounsell; Joe M O'Sullivan
Journal:  Br J Radiol       Date:  2016-09-23       Impact factor: 3.039

5.  A TRACK-REPEATING ALGORITHM FOR FAST MONTE CARLO DOSE CALCULATIONS OF PROTON RADIOTHERAPY.

Authors:  Pablo Yepes; Sharmalee Randeniya; Phillip J Taddei; Wayne D Newhauser
Journal:  Nucl Technol       Date:  2009-12-01

6.  ADVANTAGES OF MCNPX-BASED LATTICE TALLY OVER MESH TALLY IN HIGH-SPEED MONTE CARLO DOSE RECONSTRUCTION FOR PROTON RADIOTHERAPY.

Authors:  Rui Zhang; Jonas D Fontenot; Dragan Mirkovic; John S Hendricks; Wayne D Newhauser
Journal:  Nucl Technol       Date:  2013-07

7.  Water equivalent thickness values of materials used in beams of protons, helium, carbon and iron ions.

Authors:  Rui Zhang; Phillip J Taddei; Markus M Fitzek; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2010-04-06       Impact factor: 3.609

8.  Assessment of the accuracy of an MCNPX-based Monte Carlo simulation model for predicting three-dimensional absorbed dose distributions.

Authors:  U Titt; N Sahoo; X Ding; Y Zheng; W D Newhauser; X R Zhu; J C Polf; M T Gillin; R Mohan
Journal:  Phys Med Biol       Date:  2008-07-31       Impact factor: 3.609

9.  Calculation of water equivalent thickness of materials of arbitrary density, elemental composition and thickness in proton beam irradiation.

Authors:  Rui Zhang; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2009-02-13       Impact factor: 3.609

10.  Dose perturbations from implanted helical gold markers in proton therapy of prostate cancer.

Authors:  Annelise Giebeler; Jonas Fontenot; Peter Balter; George Ciangaru; Ronald Zhu; Wayne Newhauser
Journal:  J Appl Clin Med Phys       Date:  2009-01-27       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.