Coronary CT angiography.

U Joseph Schoepf1, Peter L Zwerner, Giancarlo Savino, Christopher Herzog, J Matthias Kerl, Philip Costello.   

Abstract

Owing to ongoing technical refinements and intense scientific and clinical evaluations, computed tomography (CT) of the heart has left the research realm and matured into a clinical application that is about to fulfill its promise to replace invasive cardiac catheterization in selected patient populations. CT coronary angiography is technically more challenging than other CT applications owing to the nature of its target, the continuously moving heart. Rapid technical developments in this field require constant adaptation of acquisition protocols. These challenges, however, are in no way insurmountable for users with knowledge of the general CT technique. The intent of this communication is to provide those interested in and involved with coronary CT angiography with a step-by-step "manual" describing the authors' approach to performing coronary CT angiography. Included are considerations regarding appropriate patient selection, patient medication, radiation protection, contrast enhancement, acquisition and reconstruction parameters, image display and analysis techniques, and the radiology report. The recommendations are based on the authors' experience, which spans the evolution of multi-detector row CT for cardiac applications, from its beginning to the advent of the most current generations of 64-section and dual-source CT technologies, which they believe herald the entrance of this examination into routine clinical practice. (c) RSNA, 2007.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17495176     DOI: 10.1148/radiol.2441052145

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  26 in total

Review 1.  Understanding the genetics of coronary artery disease through the lens of noninvasive imaging.

Authors:  Eunice Yang; Jose D Vargas; David A Bluemke
Journal:  Expert Rev Cardiovasc Ther       Date:  2012-01

2.  Potential of right to left ventricular volume ratio measured on chest CT for the prediction of pulmonary hypertension: correlation with pulmonary arterial systolic pressure estimated by echocardiography.

Authors:  Heon Lee; Seok Yeon Kim; Soo Jeong Lee; Jae Kyun Kim; Ryan P Reddy; U Joseph Schoepf
Journal:  Eur Radiol       Date:  2012-04-27       Impact factor: 5.315

3.  Dose levels at coronary CT angiography--a comparison of Dual Energy-, Dual Source- and 16-slice CT.

Authors:  J Matthias Kerl; Ralf W Bauer; Tobias B Maurer; Rene Aschenbach; Huedayi Korkusuz; Thomas Lehnert; Simon Deseive; Hanns Ackermann; Thomas J Vogl
Journal:  Eur Radiol       Date:  2010-09-23       Impact factor: 5.315

4.  Reduction of the total injection volume of contrast material with a short injection duration in 64-detector row CT coronary angiography.

Authors:  F Tatsugami; T Kanamoto; G Nakai; Y Takeda; H Morita; I Morinaga; S Yoshikawa; I Narabayashi
Journal:  Br J Radiol       Date:  2009-06-08       Impact factor: 3.039

5.  CT coronary angiography: quantitative assessment of myocardial perfusion using test bolus data-initial experience.

Authors:  Ashley M Groves; Vicky Goh; Sabarinath Rajasekharan; Irfan Kayani; Raymondo Endozo; John C Dickson; Leon J Menezes; Manu Shastry; Said B Habib; Peter J Ell; Brian F Hutton
Journal:  Eur Radiol       Date:  2008-05-09       Impact factor: 5.315

6.  MDCT evaluation of the cardiac venous system.

Authors:  D Lumia; D Laganà; A Canì; M Mangini; A Giorgianni; T Cafaro; E Bertolotti; S Rizzo; E Cotta; F Caravati; I Caico; C Vite; G Carrafiello; C Fugazzola
Journal:  Radiol Med       Date:  2009-07-01       Impact factor: 3.469

7.  Indications, imaging technique, and reading of cardiac computed tomography: survey of clinical practice.

Authors:  M H Maurer; E Zimmermann; P Schlattmann; C Germershausen; B Hamm; Marc Dewey
Journal:  Eur Radiol       Date:  2011-08-16       Impact factor: 5.315

8.  Impact of a vendor-specific motion-correction algorithm on image quality, interpretability, and diagnostic performance of daily routine coronary CT angiography: influence of heart rate on the effect of motion-correction.

Authors:  Heon Lee; Jeong A Kim; Ji Sung Lee; Jon Suh; Sang Hyun Paik; Jai Soung Park
Journal:  Int J Cardiovasc Imaging       Date:  2014-07-20       Impact factor: 2.357

9.  Dual-region-of-interest bolus-tracking technique for coronary computed tomographic angiography on a 320-row scanner: reduction in the interpatient variability of arterial contrast enhancement.

Authors:  Noriyuki Kai; Seitaro Oda; Daisuke Utsunomiya; Takeshi Nakaura; Yoshinori Funama; Masafumi Kidoh; Narumi Taguchi; Yuji Iyama; Yasunori Nagayama; Kenichiro Hirata; Hideaki Yuki; Daisuke Sakabe; Masahiro Hatemura; Yasuyuki Yamashita
Journal:  Br J Radiol       Date:  2017-11-08       Impact factor: 3.039

10.  Pilot study of the multicentre DISCHARGE Trial: image quality and protocol adherence results of computed tomography and invasive coronary angiography.

Authors:  Gianluca De Rubeis; Adriane E Napp; Peter Schlattmann; Jacob Geleijns; Michael Laule; Henryk Dreger; Klaus Kofoed; Mathias Sørgaard; Thomas Engstrøm; Hans Henrik Tilsted; Alberto Boi; Michele Porcu; Stefano Cossa; José F Rodríguez-Palomares; Filipa Xavier Valente; Albert Roque; Gudrun Feuchtner; Fabian Plank; Cyril Štěchovský; Theodor Adla; Stephen Schroeder; Thomas Zelesny; Matthias Gutberlet; Michael Woinke; Mihály Károlyi; Júlia Karády; Patrick Donnelly; Peter Ball; Jonathan Dodd; Mark Hensey; Massimo Mancone; Andrea Ceccacci; Marina Berzina; Ligita Zvaigzne; Gintare Sakalyte; Algidas Basevičius; Małgorzata Ilnicka-Suckiel; Donata Kuśmierz; Rita Faria; Vasco Gama-Ribeiro; Imre Benedek; Teodora Benedek; Filip Adjić; Milenko Čanković; Colin Berry; Christian Delles; Erica Thwaite; Gershan Davis; Juhani Knuuti; Mikko Pietilä; Cezary Kepka; Mariusz Kruk; Radosav Vidakovic; Aleksandar N Neskovic; Iñigo Lecumberri; Ignacio Diez Gonzales; Balazs Ruzsics; Mike Fisher; Marc Dewey; Marco Francone
Journal:  Eur Radiol       Date:  2019-12-16       Impact factor: 5.315

View more