Literature DB >> 19568701

MDCT evaluation of the cardiac venous system.

D Lumia1, D Laganà, A Canì, M Mangini, A Giorgianni, T Cafaro, E Bertolotti, S Rizzo, E Cotta, F Caravati, I Caico, C Vite, G Carrafiello, C Fugazzola.   

Abstract

PURPOSE: This study was undertaken to evaluate the usefulness of electrocardiographically (ECG)-gated multidetector-row computed tomography (MDCT) for the assessment of the coronary venous system and detection of its anatomical variants, in order to identify those suitable for lead placement in cardiac resynchronisation therapy (CRT).
MATERIALS AND METHODS: We retrospectively examined the coronary MDCT studies of 89 patients (73 males, 16 females, average age 62.5 years, range 31-79) referred for suspected coronary artery disease. The cardiac venous system was assessed in all patients using three-dimensional (3D) postprocessing on a dedicated Vitrea workstation (five patients were excluded from the analysis).
RESULTS: The coronary sinus, the great cardiac vein, the anterior interventricular vein and the middle cardiac vein were visualised in all cases. The lateral cardiac vein was visualised in 56/84 patients (67%) and the posterior cardiac vein in 63/84 patients (75%), never both missing. Along the postero-lateral wall of the left ventricle, only one branch was present in 44 cases, two branches in 21 cases and three or more branches in 19/84 cases (22%). Evaluation of the maximum diameter revealed that the lateral vein was dominant over the posterior vein in 20/40 cases. The small cardiac vein was visualised in 11/84 cases.
CONCLUSIONS: MDCT provides good depiction of the cardiac venous system, enabling the study of the vessel course and the identification of anatomical variants. Hence, this imaging technique could be proposed for the preoperative planning of CRT in selected patients.

Entities:  

Mesh:

Year:  2009        PMID: 19568701     DOI: 10.1007/s11547-009-0417-3

Source DB:  PubMed          Journal:  Radiol Med        ISSN: 0033-8362            Impact factor:   3.469


  30 in total

Review 1.  Radiation dose in computed tomography of the heart.

Authors:  Richard L Morin; Thomas C Gerber; Cynthia H McCollough
Journal:  Circulation       Date:  2003-02-18       Impact factor: 29.690

2.  [Normal anatomy of the vessels of the heart with 16-row multislice computed tomography].

Authors:  Filippo Cademartiri; Riccardo Marano; Giacomo Luccichenti; Nico Mollet; Koen Nieman; Pim J De Feyter; Gabriel P Krestin; Lorenzo Bonomo
Journal:  Radiol Med       Date:  2004 Jan-Feb       Impact factor: 3.469

3.  Imaging of the cardiac venous system: comparison of MDCT and conventional angiography.

Authors:  Georg Mühlenbruch; Ralf Koos; Joachim E Wildberger; Rolf W Günther; Andreas H Mahnken
Journal:  AJR Am J Roentgenol       Date:  2005-11       Impact factor: 3.959

4.  Noninvasive evaluation of cardiac veins with 16-MDCT angiography.

Authors:  Suhny Abbara; Ricardo C Cury; Koen Nieman; Vivek Reddy; Fabian Moselewski; Steven Schmidt; Maros Ferencik; Udo Hoffmann; Thomas J Brady; Stephan Achenbach
Journal:  AJR Am J Roentgenol       Date:  2005-10       Impact factor: 3.959

5.  The coronary venous anatomy: a segmental approach to aid cardiac resynchronization therapy.

Authors:  Jagmeet P Singh; Stuart Houser; E Kevin Heist; Jeremy N Ruskin
Journal:  J Am Coll Cardiol       Date:  2005-07-05       Impact factor: 24.094

Review 6.  Non-coronary cardiac CT imaging.

Authors:  Pamela K Woodard; Sanjeev Bhalla; Cylen Javidan-Nejad; Fernando R Gutierrez
Journal:  Semin Ultrasound CT MR       Date:  2006-02       Impact factor: 1.875

7.  Noninvasive coronary artery imaging: magnetic resonance angiography and multidetector computed tomography angiography: a scientific statement from the american heart association committee on cardiovascular imaging and intervention of the council on cardiovascular radiology and intervention, and the councils on clinical cardiology and cardiovascular disease in the young.

Authors:  David A Bluemke; Stephan Achenbach; Matthew Budoff; Thomas C Gerber; Bernard Gersh; L David Hillis; W Gregory Hundley; Warren J Manning; Beth Feller Printz; Matthias Stuber; Pamela K Woodard
Journal:  Circulation       Date:  2008-06-27       Impact factor: 29.690

8.  Three-dimensional visualization of the coronary venous system using multidetector row computed tomography.

Authors:  Hiroshi Tada; Kenji Kurosaki; Shigeto Naito; Keiko Koyama; Kazuhiro Itoi; Sachiko Ito; Marehiko Ueda; Goro Shinbo; Hiroshi Hoshizaki; Akihiko Nogami; Shigeru Oshima; Koichi Taniguchi
Journal:  Circ J       Date:  2005-02       Impact factor: 2.993

9.  Prospective evaluation of the anatomy of the coronary venous system using multidetector row computed tomography.

Authors:  Luc Christiaens; Paul Ardilouze; Stéphanie Ragot; Jean Mergy; Joseph Allal
Journal:  Int J Cardiol       Date:  2007-05-09       Impact factor: 4.164

10.  Interventricular and intraventricular dyssynchrony are common in heart failure patients, regardless of QRS duration.

Authors:  Stefano Ghio; Cristina Constantin; Catherine Klersy; Alessandra Serio; Alessandra Fontana; Carlo Campana; Luigi Tavazzi
Journal:  Eur Heart J       Date:  2004-04       Impact factor: 29.983

View more
  4 in total

1.  Clinical indications for cardiac computed tomography. From the Working Group of the Cardiac Radiology Section of the Italian Society of Medical Radiology (SIRM).

Authors:  E di Cesare; I Carbone; A Carriero; M Centonze; F De Cobelli; R De Rosa; P Di Renzi; A Esposito; R Faletti; R Fattori; M Francone; A Giovagnoni; L La Grutta; G Ligabue; L Lovato; R Marano; M Midiri; L Natale; A Romagnoli; V Russo; F Sardanelli; F Cademartiri
Journal:  Radiol Med       Date:  2012-04-01       Impact factor: 3.469

2.  Evaluation of pericardial sinuses and recesses with 2-, 4-, 16-, and 64-row multidetector CT.

Authors:  C A Ozmen; M G Akpinar; H O Akay; F B Demirkazik; M Ariyurek
Journal:  Radiol Med       Date:  2010-02-22       Impact factor: 3.469

3.  Normal anatomy and variants of the venous cardiac system in MDCT coronary angiography.

Authors:  Roberto Malagò; Giuseppe Sala; Andrea Pezzato; Camilla Barbiani; Ugolino Alfonsi; Roberto Pozzi Mucelli
Journal:  Radiol Med       Date:  2013-05-27       Impact factor: 3.469

4.  A 128-slice CT scanner helpful in localising coronary sinus ostium during CRT-D implantation - case report.

Authors:  Przemysław Jaźwiec; Dariusz Jagielski; Paweł Gać
Journal:  Pol J Radiol       Date:  2014-01-29
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.