UNLABELLED: Long-term precision of two Hologic DXA scanners was derived from repeated clinical measurements. With typical subjects, the long-term coefficients of variation were about twice the short-term. The accuracy of the measurement of changes was compromised by anomalies, but this did not seriously affect clinical conclusions.
INTRODUCTION: Long-term precision and accuracy of BMD measurements need review.
METHODS: Long-term precision was examined by selecting, from Hologic databases, subjects who had had four scans over a period of 2 to 5 years and was calculated from the SEE of a regression of BMD against time. Accuracy was assessed from relationships between changes (delta) in BA, BMD and BMC.
RESULTS: For one group of subjects, the long-term precision was 2.4% for lumbar spine, 2.3% for total hip and 2.7% for femoral neck when expressed as CVs. These values were nearly twice the short-term CVs of 1.3% for spine, 1.2% for total hip and 1.4% for femoral neck. For another group, a negative exponential regression gave a better fit, leading to CVs of 1.3% for the spine, 1.4% for total hip and 2.1% for femoral neck. Significant correlations between deltaBA and deltaBMC were found. These led to an underestimate of deltaBMD in spine and hip by 25%.
CONCLUSIONS: The poorer long-term precision for typical patients should be borne in mind in monitoring progress. The underestimate of changes could account for only a part of the underestimation by BMD measurements of the anti-fracture effects of anti-resorptive drugs.

Entities:  

Mesh:

Year:  2007        PMID: 17483864     DOI: 10.1007/s00198-007-0382-4

Source DB:  PubMed          Journal:  Osteoporos Int        ISSN: 0937-941X            Impact factor:   4.507


  22 in total

1.  Anomalies in dual energy X-ray absorptiometry measurements of total-body bone mineral during weight change using Lunar, Hologic and Norland instruments.

Authors:  P Tothill; M A Laskey; C I Orphanidou; M van Wijk
Journal:  Br J Radiol       Date:  1999-07       Impact factor: 3.039

2.  A phantom for standardization and quality control in spinal bone mineral measurements by QCT and DXA: design considerations and specifications.

Authors:  W A Kalender
Journal:  Med Phys       Date:  1992 May-Jun       Impact factor: 4.071

3.  Antifracture efficacy of antiresorptive agents are related to changes in bone density.

Authors:  R D Wasnich; P D Miller
Journal:  J Clin Endocrinol Metab       Date:  2000-01       Impact factor: 5.958

4.  Errors in dual-energy X-ray absorptiometry of the lumbar spine owing to fat distribution and soft tissue thickness during weight change.

Authors:  P Tothill; A Avenell
Journal:  Br J Radiol       Date:  1994-01       Impact factor: 3.039

5.  Long-term precision of DXA scanning assessed over seven years in forty postmenopausal women.

Authors:  R Patel; G M Blake; J Rymer; I Fogelman
Journal:  Osteoporos Int       Date:  2000       Impact factor: 4.507

6.  Anomalies in the measurement of changes in total-body bone mineral by dual-energy X-ray absorptiometry during weight change.

Authors:  P Tothill; W J Hannan; S Cowen; C P Freeman
Journal:  J Bone Miner Res       Date:  1997-11       Impact factor: 6.741

7.  A study of the long-term precision of dual-energy X-ray absorptiometry bone densitometers and implications for the validity of the least-significant-change calculation.

Authors:  T N Hangartner
Journal:  Osteoporos Int       Date:  2006-11-30       Impact factor: 4.507

8.  Monitoring osteoporosis therapies.

Authors:  Paul D Miller
Journal:  Curr Osteoporos Rep       Date:  2007-03       Impact factor: 5.096

9.  Change in lumbar spine BMD and vertebral fracture risk reduction in teriparatide-treated postmenopausal women with osteoporosis.

Authors:  Peiqi Chen; Paul D Miller; Pierre D Delmas; Derek A Misurski; John H Krege
Journal:  J Bone Miner Res       Date:  2006-11       Impact factor: 6.741

10.  An overlying fat panniculus affects femur bone mass measurement.

Authors:  Neil Binkley; Diane Krueger; Nellie Vallarta-Ast
Journal:  J Clin Densitom       Date:  2003       Impact factor: 2.963

View more
  11 in total

1.  Comment on Tothill and Hannan: precision and accuracy of measuring changes in bone mineral density by dual-energy X-ray absorptiometry.

Authors:  G Phillipov; C J Seaborn
Journal:  Osteoporos Int       Date:  2008-01-29       Impact factor: 4.507

2.  The measurement of bone mineral density of bilateral proximal humeri using DXA in patients with unilateral rotator cuff tear.

Authors:  J H Oh; B W Song; S H Kim; J-A Choi; J W Lee; S W Chung; T-Y Rhie
Journal:  Osteoporos Int       Date:  2014-07-16       Impact factor: 4.507

3.  The impact of vitamin D levels on glycemic control and bone mineral density in postmenopausal women with type 2 diabetes.

Authors:  I Perez-Diaz; G Sebastian-Barajas; Z G Hernandez-Flores; R Rivera-Moscoso; H K Osorio-Landa; A Flores-Rebollar
Journal:  J Endocrinol Invest       Date:  2015-12       Impact factor: 4.256

Review 4.  Update on Imaging-Based Measurement of Bone Mineral Density and Quality.

Authors:  Thomas M Link; Galateia Kazakia
Journal:  Curr Rheumatol Rep       Date:  2020-04-09       Impact factor: 4.592

5.  Effects of whole body vibration on bone mineral density and falls: results of the randomized controlled ELVIS study with postmenopausal women.

Authors:  S von Stengel; W Kemmler; K Engelke; W A Kalender
Journal:  Osteoporos Int       Date:  2010-03-20       Impact factor: 4.507

6.  Evaluation of the bone mineral density in the Mexican female population using the Radiofrequency Echographic Multi Spectrometry (REMS) technology.

Authors:  Rosales-Ortiz Sergio; Rivera García Elaín Nayelli
Journal:  Arch Osteoporos       Date:  2022-03-07       Impact factor: 2.617

7.  Knee flexion influences periprosthetic BMD measurement in the tibia. Suggestions for a reproducible clinical scan protocol.

Authors:  Maiken Stilling; Kjeld Søballe; Kristian Larsen; Niels Trolle Andersen; Ole Rahbek
Journal:  Acta Orthop       Date:  2010-08       Impact factor: 3.717

8.  Dual energy x-ray absorptiometry of the distal femur may be more reliable than the proximal tibia in spinal cord injury.

Authors:  Leslie R Morse; Antonio A Lazzari; Ricardo Battaglino; Kelly L Stolzmann; Kirby R Matthess; David R Gagnon; Samuel A Davis; Eric Garshick
Journal:  Arch Phys Med Rehabil       Date:  2009-05       Impact factor: 3.966

Review 9.  Bone markers and their prognostic value in metastatic bone disease: clinical evidence and future directions.

Authors:  Robert Coleman; Janet Brown; Evangelos Terpos; Allan Lipton; Matthew R Smith; Richard Cook; Pierre Major
Journal:  Cancer Treat Rev       Date:  2008-06-24       Impact factor: 12.111

10.  "Sex" and body region effects on bone mineralization in male pigs.

Authors:  Maren Bernau; Juliane Schrott; Sebastian Schwanitz; Lena Sophie Kreuzer; Armin Manfred Scholz
Journal:  Arch Anim Breed       Date:  2020-04-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.