Literature DB >> 17475709

Repeatability and reproducibility of anterior chamber angle measurement with anterior segment optical coherence tomography.

Haitao Li1, Christopher Kai Shun Leung, Carol Yim Lui Cheung, Lee Wong, Chi Pui Pang, Robert Neal Weinreb, Dennis Shun Chiu Lam.   

Abstract

AIM: To evaluate the repeatability and reproducibility of anterior chamber angle measurement obtained by anterior segment optical coherence tomography.
METHODS: Twenty-five normal subjects were invited for anterior chamber angle imaging with an anterior segment optical coherence tomography (OCT) on one randomly selected eye in three separate visits within a week. Each eye was imaged three times under room light (light intensity = 368 lux) and three times in the dark during the first visit. In the subsequent visits, each eye was imaged once in the light and once in the dark. The angle opening distance (AOD 500) and the trabecular-iris angle (TIA 500) were measured by a single observer. Only the nasal angle was analysed. Intrasession and intersession within-subject standard deviation (Sw), precision (1.96xSw), coefficient of variation (CVw) (100xSw/overall mean), and intraclass correlation coefficient (ICC) were calculated to evaluate repeatability and reproducibility.
RESULTS: For intrasession repeatability, the Sw, precision, CVw and ICC of AOD/TIA were 45 microm/2.4 degrees , 88 microm/4.7 degrees , 5.8%/4.8% and 0.97/0.95 in the light; and 45 microm/2.1 degrees , 88 microm/4.2 degrees , 7.0%/5.0% and 0.98/0.97 in the dark. For intersession reproducibility, the Sw, precision, CVw and ICC of AOD/TIA were 79 microm/3.5 degrees , 155 microm/6.8 degrees , 10.0%/7.0%, 0.91/0.89 in the light; and 64 microm/3.4 degrees , 124 microm/6.6 degrees , 9.9%/7.8% and 0.95/0.92 in the dark.
CONCLUSIONS: The anterior segment OCT demonstrated reliable anterior chamber angle measurement in different lighting conditions with good repeatability and reproducibility.

Mesh:

Year:  2007        PMID: 17475709      PMCID: PMC2095411          DOI: 10.1136/bjo.2007.118901

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  10 in total

1.  Ultrasound biomicroscopy dark room provocative testing: a quantitative method for estimating anterior chamber angle width.

Authors:  H Ishikawa; K Esaki; J M Liebmann; Y Uji; R Ritch
Journal:  Jpn J Ophthalmol       Date:  1999 Nov-Dec       Impact factor: 2.447

2.  Inadvertent corneal indentation can cause artifactitious widening of the iridocorneal angle on ultrasound biomicroscopy.

Authors:  H Ishikawa; K Inazumi; J M Liebmann; R Ritch
Journal:  Ophthalmic Surg Lasers       Date:  2000 Jul-Aug

3.  Closed-angle glaucoma; significance of sectoral variations in angle depth.

Authors:  C I PHILLIPS
Journal:  Br J Ophthalmol       Date:  1956-03       Impact factor: 4.638

4.  Clinical use of ultrasound biomicroscopy.

Authors:  C J Pavlin; K Harasiewicz; M D Sherar; F S Foster
Journal:  Ophthalmology       Date:  1991-03       Impact factor: 12.079

5.  Ultrasound biomicroscopy of anterior segment structures in normal and glaucomatous eyes.

Authors:  C J Pavlin; K Harasiewicz; F S Foster
Journal:  Am J Ophthalmol       Date:  1992-04-15       Impact factor: 5.258

6.  Anterior chamber angle measurement with optical coherence tomography: intraobserver and interobserver variability.

Authors:  Maya Müller; Gerlinde Dahmen; Erk Pörksen; Gerd Geerling; Horst Laqua; Andreas Ziegler; Hans Hoerauf
Journal:  J Cataract Refract Surg       Date:  2006-11       Impact factor: 3.351

7.  Ultrasound biomicroscopic quantitative analysis of light-dark changes associated with pupillary block.

Authors:  E K Woo; C J Pavlin; A Slomovic; N Taback; Y M Buys
Journal:  Am J Ophthalmol       Date:  1999-01       Impact factor: 5.258

8.  Measurement of ultrasound biomicroscopy images: intraobserver and interobserver reliability.

Authors:  C Tello; J Liebmann; S D Potash; H Cohen; R Ritch
Journal:  Invest Ophthalmol Vis Sci       Date:  1994-08       Impact factor: 4.799

9.  Angle recess area decreases with age in normal Japanese.

Authors:  K Esaki; H Ishikawa; J M Liebmann; D S Greenfield; Y Uji; R Ritch
Journal:  Jpn J Ophthalmol       Date:  2000 Jan-Feb       Impact factor: 2.447

10.  Ultrasound biomicroscopy. II. Intraobserver and interobserver reproducibility of measurements.

Authors:  S F Urbak; J K Pedersen; T T Thorsen
Journal:  Acta Ophthalmol Scand       Date:  1998-10
  10 in total
  33 in total

1.  Anterior segment imaging for glaucoma: OCT or UBM?

Authors:  Hiroshi Ishikawa
Journal:  Br J Ophthalmol       Date:  2007-11       Impact factor: 4.638

2.  Assessment of the anterior chamber parameters after laser iridotomy in primary angle close suspect using Pentacam and gonioscopy.

Authors:  Alireza Esmaeili; Behzad Barazandeh; Sina Ahmadi; Alireza Haghi; Seyed Mahdi Ahmadi Hosseini; Fereshteh Abolbashari
Journal:  Int J Ophthalmol       Date:  2013-10-18       Impact factor: 1.779

3.  Anterior chamber angle imaging with optical coherence tomography.

Authors:  C K-S Leung; R N Weinreb
Journal:  Eye (Lond)       Date:  2011-01-14       Impact factor: 3.775

Review 4.  Test-retest variability in structural parameters measured with glaucoma imaging devices.

Authors:  Makoto Araie
Journal:  Jpn J Ophthalmol       Date:  2012-11-09       Impact factor: 2.447

5.  Light-dark changes in iris thickness and anterior chamber angle width in eyes with occludable angles.

Authors:  Fumitaka Hirose; Masayuki Hata; Shin-ichiro Ito; Takaaki Matsuki; Yasuo Kurimoto
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-05-21       Impact factor: 3.117

6.  Visualization of conventional outflow tissue responses to netarsudil in living mouse eyes.

Authors:  Guorong Li; Dibyendu Mukherjee; Iris Navarro; Nicole E Ashpole; Joseph M Sherwood; Jinlong Chang; Darryl R Overby; Fan Yuan; Pedro Gonzalez; Casey C Kopczynski; Sina Farsiu; W Daniel Stamer
Journal:  Eur J Pharmacol       Date:  2016-04-13       Impact factor: 4.432

7.  Anterior Segment Optical Coherence Tomography: Applications for Clinical Care and Scientific Research.

Authors:  Jing Shan; Charles DeBoer; Benjamin Y Xu
Journal:  Asia Pac J Ophthalmol (Phila)       Date:  2019-04-25

8.  Repeatability assessment of anterior segment biometric measurements under accommodative and nonaccommodative conditions using an anterior segment OCT.

Authors:  Noelia Martínez-Albert; Jose J Esteve-Taboada; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-11-02       Impact factor: 3.117

Review 9.  Old and new in exploring the anterior chamber angle.

Authors:  Moisescu Raluca; Filip Mircea; Filip Andrei; Dragne Carmen; Nicolae Miruna; Triantafyllidis Grigorios; Ungureanu Ileana
Journal:  Rom J Ophthalmol       Date:  2015 Oct-Dec

10.  Validation of optical coherence tomography-based crystalline lens thickness measurements in children.

Authors:  Bret M Lehman; David A Berntsen; Melissa D Bailey; Karla Zadnik
Journal:  Optom Vis Sci       Date:  2009-03       Impact factor: 1.973