Literature DB >> 10928676

Inadvertent corneal indentation can cause artifactitious widening of the iridocorneal angle on ultrasound biomicroscopy.

H Ishikawa1, K Inazumi, J M Liebmann, R Ritch.   

Abstract

A 70-year-old Asian female with narrow angles underwent ultrasound biomicroscopy (UBM) darkroom provocative testing. The angle was narrow under light conditions and occluded in the dark, except for the inferior quadrant where the angle was wide and the iris concave. This was reproducible in four quadrants with the use of a small UBM eye cup but not the large one. A small eye cup can indent the cornea, resulting in artifactitious angle widenening. Care must be taken when using the small eye cup not to press on the cornea.

Entities:  

Mesh:

Year:  2000        PMID: 10928676

Source DB:  PubMed          Journal:  Ophthalmic Surg Lasers        ISSN: 1082-3069


  16 in total

Review 1.  Anterior segment imaging: ultrasound biomicroscopy.

Authors:  Hiroshi Ishikawa; Joel S Schuman
Journal:  Ophthalmol Clin North Am       Date:  2004-03

2.  Anatomical effects of clear lens extraction by phacoemulsification versus trabeculectomy on anterior chamber drainage angle in primary angle-closure glaucoma (PACG) patients.

Authors:  Xiaofei Man; Noel C Y Chan; Nafees Baig; Yolanda Y Y Kwong; Dexter Y L Leung; Felix C H Li; Clement C Y Tham
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-02-03       Impact factor: 3.117

Review 3.  Recent advances in ophthalmic anterior segment imaging: a new era for ophthalmic diagnosis?

Authors:  Aristides Konstantopoulos; Parwez Hossain; David F Anderson
Journal:  Br J Ophthalmol       Date:  2007-04       Impact factor: 4.638

4.  Repeatability and reproducibility of anterior chamber angle measurement with anterior segment optical coherence tomography.

Authors:  Haitao Li; Christopher Kai Shun Leung; Carol Yim Lui Cheung; Lee Wong; Chi Pui Pang; Robert Neal Weinreb; Dennis Shun Chiu Lam
Journal:  Br J Ophthalmol       Date:  2007-05-02       Impact factor: 4.638

5.  Preclinical imaging of iridocorneal angle and fundus using a modified integrated flexible handheld probe.

Authors:  Xun Jie Jeesmond Hong; Vengalathunadakal K Shinoj; Vadakke Matham Murukeshan; Mani Baskaran; Tin Aung
Journal:  J Med Imaging (Bellingham)       Date:  2017-04-10

6.  Increased iris-lens contact following spontaneous blinking: mathematical modeling.

Authors:  Rouzbeh Amini; Sara Jouzdani; Victor H Barocas
Journal:  J Biomech       Date:  2012-07-21       Impact factor: 2.712

7.  Anterior-segment imaging for assessment of glaucoma.

Authors:  Roxana Ursea; Ronald H Silverman
Journal:  Expert Rev Ophthalmol       Date:  2010-02-01

Review 8.  Angle imaging: advances and challenges.

Authors:  Desmond T L Quek; Monisha E Nongpiur; Shamira A Perera; Tin Aung
Journal:  Indian J Ophthalmol       Date:  2011-01       Impact factor: 1.848

9.  Anterior segment biometry using ultrasound biomicroscopy and the Artemis-2 very high frequency ultrasound scanner.

Authors:  Haya M Al-Farhan; Reem N Almutairi
Journal:  Clin Ophthalmol       Date:  2013-01-16

10.  Age and positional effect on the anterior chamber angle: assessment by ultrasound biomicroscopy.

Authors:  Nicholas P Bell; Kundandeep S Nagi; Ricardo J Cumba; Alice Z Chuang; David A Lee; Thomas C Prager; Kavita Rao; Robert M Feldman
Journal:  ISRN Ophthalmol       Date:  2013-04-23
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.