Literature DB >> 17081861

Anterior chamber angle measurement with optical coherence tomography: intraobserver and interobserver variability.

Maya Müller1, Gerlinde Dahmen, Erk Pörksen, Gerd Geerling, Horst Laqua, Andreas Ziegler, Hans Hoerauf.   

Abstract

PURPOSE: To assess intraobserver and interobserver variability of anterior segment optical coherence tomography (AS-OCT) as an objective diagnostic tool to quantify the anterior chamber angle and opening width.
SETTING: University Eye Clinic, Lübeck, Germany.
METHODS: The anterior chamber angle and opening width were assessed in 18 eyes of 9 healthy volunteers by 2 observers. Intraobserver reproducibility was evaluated by calculating an intraclass correlation coefficient (ICC) in a mixed model. Each observer had a separate model using information from 5 scans. Interobserver variability was determined by Bland-Altman analysis. The ICC was calculated in a mixed model using a residual maximum likelihood method. The results of 3 and 5 repeated scans were evaluated to indicate the change to 1 measurement application.
RESULTS: The mean anterior chamber angle measurement was 35.9 degrees +/- 5.7 (SD) for observer A and 36.2 +/- 5.7 degrees for observer B. The ICC was 0.94 and 0.91, respectively. The mean opening width was 315 +/- 62 microm for observer A and 317 +/- 60 microm for observer B. The ICC was 0.97 and 0.93, respectively. Interobserver comparisons showed a mean difference between anterior chamber angle measurements of -0.27 +/- 1.6 degrees, a limit of agreement (LOA) interval from -3.52 to 2.98 degrees, and an ICC estimate of 0.96. The mean difference in opening width measurements was 2.40 +/- 12.40 microm, the LOA from -27.20 to 22.40 microm, and the estimated ICC 0.96. Using 1 instead of the mean of 5 measurements, the LOA range increased by 3.46 degrees for the anterior chamber angle and 30.0 microm for the opening width.
CONCLUSION: Anterior chamber angle and opening width measurements by OCT showed low intraobserver and interobserver variability, indicating OCT is a valuable technique for quantitative assessment that provides reproducible measurements and objective documentation by different examiners.

Entities:  

Mesh:

Year:  2006        PMID: 17081861     DOI: 10.1016/j.jcrs.2006.07.014

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  28 in total

1.  Measurement of early changes in anterior chamber morphology after cataract extraction measured by anterior segment optical coherence tomography.

Authors:  Kozue Kasai; Genichiro Takahashi; Koichi Kumegawa; Murat Dogru
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-08-21       Impact factor: 3.117

2.  Repeatability and reproducibility of anterior chamber angle measurement with anterior segment optical coherence tomography.

Authors:  Haitao Li; Christopher Kai Shun Leung; Carol Yim Lui Cheung; Lee Wong; Chi Pui Pang; Robert Neal Weinreb; Dennis Shun Chiu Lam
Journal:  Br J Ophthalmol       Date:  2007-05-02       Impact factor: 4.638

3.  Anterior chamber angle imaging with optical coherence tomography.

Authors:  C K-S Leung; R N Weinreb
Journal:  Eye (Lond)       Date:  2011-01-14       Impact factor: 3.775

4.  Anterior segment OCT imaging in opaque grafts with secondary glaucoma following tectonic penetrating keratoplasty for perforated corneal ulcers.

Authors:  T Dada; B M Shah; S J Bali; N Bansal; A Panda; M Vanathi
Journal:  Eye (Lond)       Date:  2011-09-09       Impact factor: 3.775

Review 5.  Test-retest variability in structural parameters measured with glaucoma imaging devices.

Authors:  Makoto Araie
Journal:  Jpn J Ophthalmol       Date:  2012-11-09       Impact factor: 2.447

6.  Evaluation of anterior chamber parameters with spectral-domain optical coherence tomography.

Authors:  Isabel Pinilla Lozano; Carmen López de la Fuente; Francisco Segura; Elvira Orduna Hospital; Ana Sánchez-Cano
Journal:  Jpn J Ophthalmol       Date:  2017-11-29       Impact factor: 2.447

7.  Repeatability assessment of anterior segment biometric measurements under accommodative and nonaccommodative conditions using an anterior segment OCT.

Authors:  Noelia Martínez-Albert; Jose J Esteve-Taboada; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-11-02       Impact factor: 3.117

Review 8.  Old and new in exploring the anterior chamber angle.

Authors:  Moisescu Raluca; Filip Mircea; Filip Andrei; Dragne Carmen; Nicolae Miruna; Triantafyllidis Grigorios; Ungureanu Ileana
Journal:  Rom J Ophthalmol       Date:  2015 Oct-Dec

9.  Changes of anterior chamber architecture induced by laser peripheral iridotomy in acute angle closure crisis.

Authors:  J D Unterlauft; Y Yafai; P Wiedemann
Journal:  Int Ophthalmol       Date:  2014-08-02       Impact factor: 2.031

Review 10.  Quantitative evaluation of anterior segment parameters in the era of imaging.

Authors:  Syril Dorairaj; Jeffrey M Liebmann; Robert Ritch
Journal:  Trans Am Ophthalmol Soc       Date:  2007
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.