Literature DB >> 18417014

Advances in rubidium PET and integrated imaging with CT angiography.

Mark F Smith1.   

Abstract

The role of rubidium-82 (Rb-82) positron emission tomography (PET) in the evaluation and care of patients with suspected coronary artery disease is evolving in conjunction with advances in PET instrumentation, data analysis, and clinical research. Instrumentation developments such as three-dimensional acquisition, new scintillator materials, and x-ray CT help to improve the quality of Rb-82 images. New approaches to kinetic modeling and software tools for analysis of clinical Rb-82 studies are being developed and evaluated, enabling quantification of absolute myocardial blood flow and flow reserve. Recent clinical research studies are providing new insights into the value of Rb-82 cardiac imaging compared with single photon emission CT myocardial perfusion imaging. Integrated x-ray CT angiography and Rb-82 PET perfusion imaging on hybrid PET/CT systems is an exciting new prospect. Complementary anatomical and functional information on atherosclerosis and ischemia can be provided in a single imaging session for better diagnosis and risk stratification of patients with coronary artery disease.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18417014     DOI: 10.1007/s11886-008-0023-3

Source DB:  PubMed          Journal:  Curr Cardiol Rep        ISSN: 1523-3782            Impact factor:   2.931


  45 in total

1.  Quantification of nuclear cardiac images: the Yale approach.

Authors:  Yi-Hwa Liu
Journal:  J Nucl Cardiol       Date:  2007-07       Impact factor: 5.952

2.  Impact of myocardial perfusion imaging with PET and (82)Rb on downstream invasive procedure utilization, costs, and outcomes in coronary disease management.

Authors:  Michael E Merhige; William J Breen; Victoria Shelton; Teresa Houston; Brian J D'Arcy; Anthony F Perna
Journal:  J Nucl Med       Date:  2007-07       Impact factor: 10.057

Review 3.  Coronary CT angiography.

Authors:  Udo Hoffmann; Maros Ferencik; Ricardo C Cury; Antonio J Pena
Journal:  J Nucl Med       Date:  2006-05       Impact factor: 10.057

4.  Myocardial perfusion with rubidium-82. I. Measurement of extraction fraction and flow with external detectors.

Authors:  N A Mullani; R A Goldstein; K L Gould; S K Marani; D J Fisher; H A O'Brien; M D Loberg
Journal:  J Nucl Med       Date:  1983-10       Impact factor: 10.057

5.  Consequences of using a simplified kinetic model for dynamic PET data.

Authors:  P G Coxson; R H Huesman; L Borland
Journal:  J Nucl Med       Date:  1997-04       Impact factor: 10.057

6.  Comparison of 2-dimensional and 3-dimensional cardiac 82Rb PET studies.

Authors:  J R Votaw; M White
Journal:  J Nucl Med       Date:  2001-05       Impact factor: 10.057

Review 7.  Clinical myocardial perfusion PET/CT.

Authors:  Marcelo F Di Carli; Sharmila Dorbala; Jolene Meserve; Georges El Fakhri; Arkadiusz Sitek; Stephen C Moore
Journal:  J Nucl Med       Date:  2007-05       Impact factor: 10.057

8.  Imaging characteristics of a 3-dimensional GSO whole-body PET camera.

Authors:  Suleman Surti; Joel S Karp
Journal:  J Nucl Med       Date:  2004-06       Impact factor: 10.057

9.  Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: comparison with ECG-gated Tc-99m sestamibi SPECT.

Authors:  Timothy M Bateman; Gary V Heller; A Iain McGhie; John D Friedman; James A Case; Jan R Bryngelson; Ginger K Hertenstein; Kelly L Moutray; Kimberly Reid; S James Cullom
Journal:  J Nucl Cardiol       Date:  2006 Jan-Feb       Impact factor: 5.952

10.  Effect of reconstruction algorithms on myocardial blood flow measurement with 13N-ammonia PET.

Authors:  Grace P Chen; Kelley R Branch; Adam M Alessio; Pam Pham; Ramin Tabibiazar; Paul Kinahan; James H Caldwell
Journal:  J Nucl Med       Date:  2007-07-13       Impact factor: 10.057

View more
  1 in total

1.  Myocardial perfusion quantitation with 15O-labelled water PET: high reproducibility of the new cardiac analysis software (Carimas).

Authors:  Sergey V Nesterov; Chunlei Han; Maija Mäki; Sami Kajander; Alexandru G Naum; Hans Helenius; Irina Lisinen; Heikki Ukkonen; Mikko Pietilä; Esa Joutsiniemi; Juhani Knuuti
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-04-30       Impact factor: 9.236

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.