Literature DB >> 17466441

Pulsatile flow phantom for ultrasound image-guided HIFU treatment of vascular injuries.

Robyn Greaby1, Vesna Zderic, Shahram Vaezy.   

Abstract

A pulsatile flow phantom was developed for studies of ultrasound image-guided high intensity focused ultrasound (HIFU) application in transcutaneous hemostasis of injured blood vessels. The flow phantom consisted of a pulsatile pump system with instrumented excised porcine carotid artery, which was imbedded in a transparent agarose gel to model structural configuration of in vivo tissues. Heparinized porcine blood was circulated through the phantom. The artery was injured using an 18-gauge needle to model a penetrating injury in human peripheral vasculature. A HIFU transducer with the diameter of 7 cm, focal length of 6.3 cm and frequency of 3.4 MHz was used to seal the puncture. Ultrasound imaging was used to localize and target the puncture site and to monitor the HIFU treatment. Triphasic blood flows present in the human arteries were reproduced, with flow rates of 50 to 500 mL/min, pulse rates of 62 to 138 beats/min and peak pressures of 100 to 250 mm Hg. The penetrating injury of an artery was mimicked successfully in the flow phantom setting and was easily visualized both optically through the transparent gel and with power Doppler ultrasound imaging. Hemostasis was achieved in 55 +/- 31 s (n = 9) of HIFU application. Histologic observations showed that a HIFU-sealed puncture was filled with clotted blood and covered with a fibrin cap. The pulsatile flow phantom provides a controlled and repeatable environment for studies of transcutaneous image-guided HIFU application in hemostasis of a variety of blood vessel injuries.

Entities:  

Mesh:

Year:  2007        PMID: 17466441      PMCID: PMC2692665          DOI: 10.1016/j.ultrasmedbio.2007.02.011

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  33 in total

1.  Ultrasonic backscattering from porcine whole blood of varying hematocrit and shear rate under pulsatile flow.

Authors:  Y H Lin; K K Shung
Journal:  Ultrasound Med Biol       Date:  1999-09       Impact factor: 2.998

2.  A real vessel phantom for flow imaging: 3-D Doppler ultrasound of steady flow.

Authors:  W Dabrowski; J Dunmore-Buyze; H N Cardinal; A Fenster
Journal:  Ultrasound Med Biol       Date:  2001-01       Impact factor: 2.998

3.  Real-time visualization of high-intensity focused ultrasound treatment using ultrasound imaging.

Authors:  S Vaezy; X Shi; R W Martin; E Chi; P I Nelson; M R Bailey; L A Crum
Journal:  Ultrasound Med Biol       Date:  2001-01       Impact factor: 2.998

Review 4.  High intensity focused ultrasound: a method of hemostasis.

Authors:  S Vaezy; R Martin; L Crum
Journal:  Echocardiography       Date:  2001-05       Impact factor: 1.724

Review 5.  Interventional techniques in vascular trauma.

Authors:  T M Scalea; S Sclafani
Journal:  Surg Clin North Am       Date:  2001-12       Impact factor: 2.741

6.  An historical tour of vascular injury management: from its inception to the new millennium.

Authors:  N M Rich; P Rhee
Journal:  Surg Clin North Am       Date:  2001-12       Impact factor: 2.741

7.  Angiographic embolization of bilateral internal iliac arteries to control life-threatening hemorrhage after blunt trauma to the pelvis.

Authors:  G C Velmahos; S Chahwan; S E Hanks; J A Murray; T V Berne; J Asensio; D Demetriades
Journal:  Am Surg       Date:  2000-09       Impact factor: 0.688

8.  Detection of bleeding in injured femoral arteries with contrast-enhanced sonography.

Authors:  Wenbo Luo; Vesna Zderic; Stephen Carter; Lawrence Crum; Shahram Vaezy
Journal:  J Ultrasound Med       Date:  2006-09       Impact factor: 2.153

9.  Nonstenotic internal carotid arteries: effects of age and blood pressure at the time of scanning on Doppler US velocity measurements.

Authors:  E B Spencer; D H Sheafor; B S Hertzberg; J D Bowie; R C Nelson; B A Carroll; M A Kliewer
Journal:  Radiology       Date:  2001-07       Impact factor: 11.105

Review 10.  Newer diagnostic modalities for vascular injuries: the way we were, the way we are.

Authors:  L D Britt; L J Weireter; F J Cole
Journal:  Surg Clin North Am       Date:  2001-12       Impact factor: 2.741

View more
  7 in total

1.  Evaluation of a tissue-mimicking thermochromic phantom for radiofrequency ablation.

Authors:  Andrew S Mikhail; Ayele H Negussie; Cole Graham; Manoj Mathew; Bradford J Wood; Ari Partanen
Journal:  Med Phys       Date:  2016-07       Impact factor: 4.071

2.  In vivo Sonothrombolysis of Ear Marginal Vein of Rabbits Monitored with High-frequency Ultrasound Needle Transducer.

Authors:  Ruimin Chen; Dong-Guk Paeng; Kwok Ho Lam; Qifa Zhou; K Kirk Shung; Naoki Matsuoka; Mark S Humayun
Journal:  J Med Biol Eng       Date:  2013       Impact factor: 1.553

3.  Automatic Hemorrhage Detection From Color Doppler Ultrasound Using a Generative Adversarial Network (GAN)-Based Anomaly Detection Method.

Authors:  Jhimli Mitra; Jianwei Qiu; Michael MacDonald; Prem Venugopal; Kirk Wallace; Hossam Abdou; Michael Richmond; Noha Elansary; Joseph Edwards; Neerav Patel; Jonathan Morrison; Luca Marinelli
Journal:  IEEE J Transl Eng Health Med       Date:  2022-08-19

4.  Investigating atherosclerotic plaque phantoms for ultrasound therapy.

Authors:  Michalis Sotiriou; Marinos Yiannakou; Christakis Damianou
Journal:  J Ultrasound       Date:  2022-01-31

5.  Thermochromic tissue-mimicking phantom for optimisation of thermal tumour ablation.

Authors:  Ayele H Negussie; Ari Partanen; Andrew S Mikhail; Sheng Xu; Nadine Abi-Jaoudeh; Subha Maruvada; Bradford J Wood
Journal:  Int J Hyperthermia       Date:  2016-04-20       Impact factor: 3.914

6.  Nanoparticle Attachment to Erythrocyte Via the Glycophorin A Targeted ERY1 Ligand Enhances Binding without Impacting Cellular Function.

Authors:  Kaustuv Sahoo; Rangika S Hikkaduwa Koralege; Nicholas Flynn; Samyukta Koteeswaran; Peter Clark; Steve Hartson; Jing Liu; Joshua D Ramsey; Carey Pope; Ashish Ranjan
Journal:  Pharm Res       Date:  2016-01-26       Impact factor: 4.200

7.  Thermal characteristics of non-biological vessel phantoms for treatment of varicose veins using high-intensity focused ultrasound.

Authors:  Mi-Sun Kim; Ju-Young Kim; Si-Cheol Noh; Heung-Ho Choi
Journal:  PLoS One       Date:  2017-04-06       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.