Literature DB >> 11425992

Nonstenotic internal carotid arteries: effects of age and blood pressure at the time of scanning on Doppler US velocity measurements.

E B Spencer1, D H Sheafor, B S Hertzberg, J D Bowie, R C Nelson, B A Carroll, M A Kliewer.   

Abstract

PURPOSE: To assess the effects of age and blood pressure at the time of scanning on internal carotid artery velocities and cross-sectional diameter at Doppler ultrasonography (US).
MATERIALS AND METHODS: During 12 months, 1,020 consecutive patients underwent internal carotid artery Doppler US. No or minimal arterial disease was found in 142 patients (67 women, 75 men). Blood pressure was recorded prior to examination. The angle-corrected internal carotid artery peak systolic and end-diastolic velocities were obtained. The effects of systolic blood pressure, diastolic blood pressure, pulse pressure, age, chronic hypertension, and medications for hypertension on velocities were evaluated by using linear regression analysis.
RESULTS: Peak systolic velocity was influenced by age (P =.008), systolic blood pressure (P =.009), diastolic blood pressure (P =.003), and pulse pressure (P =.017) but not history of hypertension (P =.53) or antihypertensive medication use (P =.77). Increasing age decreased peak systolic velocity by 0.34 cm/sec/y. End-diastolic velocity was influenced by age (P <.001) but not by systolic, diastolic, or pulse pressure (all P values were >.13).
CONCLUSION: Internal carotid artery peak systolic velocities decrease with advancing age and increase with increasing pulse pressure. The effects of blood pressure at the time of scanning are small, but isolated systolic hypertension could cause increases in spurious velocity.

Entities:  

Mesh:

Year:  2001        PMID: 11425992     DOI: 10.1148/radiology.220.1.r01jl33174

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  5 in total

1.  Pulsatile flow phantom for ultrasound image-guided HIFU treatment of vascular injuries.

Authors:  Robyn Greaby; Vesna Zderic; Shahram Vaezy
Journal:  Ultrasound Med Biol       Date:  2007-04-27       Impact factor: 2.998

2.  Function of circle of Willis.

Authors:  Zvonimir Vrselja; Hrvoje Brkic; Stefan Mrdenovic; Radivoje Radic; Goran Curic
Journal:  J Cereb Blood Flow Metab       Date:  2014-01-29       Impact factor: 6.200

3.  Diagnostics and characterisation of preocclusive stenoses and occlusions of the internal carotid artery with B-flow.

Authors:  E M Jung; R Kubale; G Ritter; M T Gallegos; K-P Jungius; N Rupp; D-A Clevert
Journal:  Eur Radiol       Date:  2006-05-16       Impact factor: 5.315

4.  Color Doppler, power Doppler and B-flow ultrasound in the assessment of ICA stenosis: Comparison with 64-MD-CT angiography.

Authors:  D-A Clevert; T Johnson; E M Jung; D-A Clevert; P M Flach; T I Strautz; G Ritter; M T Gallegos; R Kubale; C Becker; M Reiser
Journal:  Eur Radiol       Date:  2006-11-22       Impact factor: 7.034

5.  Carotid velocities determine cerebral blood flow deficits in elderly men with carotid stenosis <50%.

Authors:  Arkadiusz Siennicki-Lantz; Per Wollmer; Sölve Elmståhl
Journal:  Int J Vasc Med       Date:  2012-06-19
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.