Real-time visualization of high-intensity focused ultrasound treatment using ultrasound imaging.

S Vaezy1, X Shi, R W Martin, E Chi, P I Nelson, M R Bailey, L A Crum.   

Abstract

High-intensity focused ultrasound (HIFU) and conventional B-mode ultrasound (US) imaging were synchronized to develop a system for real-time visualization of HIFU treatment. The system was tested in vivo in pig liver. The HIFU application resulted in the appearance of a hyperechoic spot at the focus that faded gradually after cessation of HIFU exposure. The duration of HIFU exposure needed for a hyperechoic spot to appear, was inversely related to the HIFU intensity. The threshold intensity required to produce a hyperechoic spot in liver in < 1 s was 970 W/cm(2), in situ. At this HIFU dose, no immediate cellular damage was observed, providing a potential for pretreatment targeting. The real-time visualization method was used in hemostasis of actively bleeding internal pelvic vessels, allowing targeting and monitoring of successful treatment. Real-time US imaging may provide a useful tool for image-guided HIFU therapy.

Entities:  

Mesh:

Year:  2001        PMID: 11295268     DOI: 10.1016/s0301-5629(00)00279-9

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  51 in total

1.  Analysis of clinical effect of high-intensity focused ultrasound on liver cancer.

Authors:  Chuan-Xing Li; Guo-Liang Xu; Zhen-You Jiang; Jian-Jun Li; Guang-Yu Luo; Hong-Bo Shan; Rong Zhang; Yin Li
Journal:  World J Gastroenterol       Date:  2004-08-01       Impact factor: 5.742

2.  Experimental evaluation of lesion prediction modelling in the presence of cavitation bubbles: intended for high-intensity focused ultrasound prostate treatment.

Authors:  L Curiel; F Chavrier; B Gignoux; S Pichardo; S Chesnais; J Y Chapelon
Journal:  Med Biol Eng Comput       Date:  2004-01       Impact factor: 2.602

Review 3.  High-Intensity Focused Ultrasound: Current Status for Image-Guided Therapy.

Authors:  Alexander Copelan; Jason Hartman; Monzer Chehab; Aradhana M Venkatesan
Journal:  Semin Intervent Radiol       Date:  2015-12       Impact factor: 1.513

4.  Improved visualization of high-intensity focused ultrasound lesions.

Authors:  Ronald H Silverman; Robert Muratore; Jeffrey A Ketterling; Jonathan Mamou; D Jackson Coleman; Ernest J Feleppa
Journal:  Ultrasound Med Biol       Date:  2006-11       Impact factor: 2.998

5.  Pulsatile flow phantom for ultrasound image-guided HIFU treatment of vascular injuries.

Authors:  Robyn Greaby; Vesna Zderic; Shahram Vaezy
Journal:  Ultrasound Med Biol       Date:  2007-04-27       Impact factor: 2.998

6.  Magnetic resonance imaging of boiling induced by high intensity focused ultrasound.

Authors:  Tatiana D Khokhlova; Michael S Canney; Donghoon Lee; Kenneth I Marro; Lawrence A Crum; Vera A Khokhlova; Michael R Bailey
Journal:  J Acoust Soc Am       Date:  2009-04       Impact factor: 1.840

7.  Prevention of post-focal thermal damage by formation of bubbles at the focus during high intensity focused ultrasound therapy.

Authors:  Vesna Zderic; Jessica Foley; Wenbo Luo; Shahram Vaezy
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

Review 8.  MR-guided focused ultrasound surgery, present and future.

Authors:  David Schlesinger; Stanley Benedict; Chris Diederich; Wladyslaw Gedroyc; Alexander Klibanov; James Larner
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

9.  Development of a spherically focused phased array transducer for ultrasonic image-guided hyperthermia.

Authors:  Jingfei Liu; Josquin Foiret; Douglas N Stephens; Olivier Le Baron; Katherine W Ferrara
Journal:  Phys Med Biol       Date:  2016-06-29       Impact factor: 3.609

10.  A new active cavitation mapping technique for pulsed HIFU applications--bubble Doppler.

Authors:  Tong Li; Tatiana D Khokhlova; Oleg A Sapozhnikov; Matthew O'Donnell; Joo Ha Hwang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-10       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.