Literature DB >> 16929018

Detection of bleeding in injured femoral arteries with contrast-enhanced sonography.

Wenbo Luo1, Vesna Zderic, Stephen Carter, Lawrence Crum, Shahram Vaezy.   

Abstract

OBJECTIVE: The purpose of this study was to investigate the feasibility of detecting acute arterial bleeding by means of contrast-enhanced sonography.
METHODS: Puncture injury was produced transcutaneously with an 18-gauge needle in 26 femoral arteries (13 in the control group and 13 in the contrast-enhanced group) of rabbits. A sonographic contrast agent (Optison; Mallinckrodt Inc, St Louis, MO) was administered intravenously at a dose of 0.06 to 0.07 mL/kg. Sonography of the femoral arteries was performed before and after injury, both before and after injection of Optison, with B-mode imaging, color Doppler imaging, and pulse inversion harmonic imaging (PIHI).
RESULTS: The specific location of active bleeding could not be visualized in B-mode and PIHI scans in the control group (no Optison injection). After administration of Optison, the bleeding site was visualized because of the increased echogenicity of the extravasated blood at the puncture site in both B-mode imaging and PIHI. In color Doppler images, bleeding sites were localized successfully in 84.6% of the cases in the presence of Optison and in 30.8% of the cases without Optison. Histologic examination (light microscopy) of the hematoma confirmed the presence of contrast agent microbubbles in the extravascular space surrounding the artery.
CONCLUSIONS: Contrast-enhanced sonography may provide an effective method for detecting arterial bleeding.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16929018     DOI: 10.7863/jum.2006.25.9.1169

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  3 in total

1.  Pulsatile flow phantom for ultrasound image-guided HIFU treatment of vascular injuries.

Authors:  Robyn Greaby; Vesna Zderic; Shahram Vaezy
Journal:  Ultrasound Med Biol       Date:  2007-04-27       Impact factor: 2.998

2.  Contrast-enhanced ultrasonography revealed active thoracic bleeding.

Authors:  Takaaki Sugihara; Masahiko Koda; Shiho Tokunaga; Tomomitsu Matono; Takakazu Nagahara; Masaru Ueki; Yoshikazu Murawaki; Toshio Kaminou
Journal:  J Med Ultrason (2001)       Date:  2010-03-05       Impact factor: 1.314

3.  Contrast-enhanced ultrasonography of post-interventional hematoma: the bleeding mushroom is growing inside.

Authors:  Francesca Di Vece; Paola Tombesi; Lara Bianchi; Matteo Bertini; Sergio Sartori
Journal:  J Med Ultrason (2001)       Date:  2018-02-16       Impact factor: 1.314

  3 in total