Literature DB >> 12571202

Bicycle exercise stress in PET for assessment of coronary flow reserve: repeatability and comparison with adenosine stress.

Christophe A Wyss1, Pascal Koepfli, Krzysztof Mikolajczyk, Cyrill Burger, Gustav K von Schulthess, Philipp A Kaufmann.   

Abstract

UNLABELLED: PET allows absolute measurements of myocardial blood flow (MBF). The aim of the present study was to evaluate the feasibility and repeatability of supine bicycle exercise stress, compared with standard adenosine stress, in PET.
METHODS: In 11 healthy volunteers, MBF was assessed at rest, during adenosine-induced (140 microg/kg/min over 7 min) hyperemia, and immediately after supine bicycle exercise (mean workload, 130 W, which is 70% of the predicted value) using PET and (15)O-H(2)O. The assessment was then repeated after 20 min. Coronary flow reserve (CFR) was calculated as hyperemic/resting MBF for adenosine stress and exercise stress. Repeatability was evaluated according to the method of Bland and Altman.
RESULTS: No significant differences were found between the paired resting MBF (1.22 +/- 0.16 vs. 1.26 +/- 0.21 mL/min/g; mean difference, 3% +/- 11%) and the hyperemic MBF with adenosine stress (5.13 +/- 0.74 vs. 4.97 +/- 1.05; mean difference, -4% +/- 14%) or exercise stress (2.35 +/- 0.66 vs. 2.25 +/- 0.61; mean difference, -4% +/- 19%). CFR was reproducible with adenosine stress (4.23 +/- 0.62 vs. 4.05 +/- 1.06, P = not statistically significant; mean difference, -5% +/- 19%) and exercise stress (1.91 +/- 0.46 vs. 1.80 +/- 0.44, P = not statistically significant; mean difference, -5% +/- 15%). Repeatability coefficients for MBF were 0.26 (rest), 1.34 (adenosine stress), and 0.82 (exercise stress) mL/min/g.
CONCLUSION: Assessment of CFR with (15)O-H(2)O and PET using bicycle exercise in the PET scanner is feasible and at least as repeatable as using adenosine stress.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12571202

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  30 in total

1.  Intra- and inter-operator repeatability of myocardial blood flow and myocardial flow reserve measurements using rubidium-82 pet and a highly automated analysis program.

Authors:  Ran Klein; Jennifer M Renaud; Maria C Ziadi; Stephanie L Thorn; Andy Adler; Rob S Beanlands; Robert A deKemp
Journal:  J Nucl Cardiol       Date:  2010-04-13       Impact factor: 5.952

Review 2.  Quantification of myocardial blood flow and flow reserve: Technical aspects.

Authors:  Ran Klein; Rob S B Beanlands; Robert A deKemp
Journal:  J Nucl Cardiol       Date:  2010-08       Impact factor: 5.952

Review 3.  Regulation of increased blood flow (hyperemia) to muscles during exercise: a hierarchy of competing physiological needs.

Authors:  Michael J Joyner; Darren P Casey
Journal:  Physiol Rev       Date:  2015-04       Impact factor: 37.312

4.  Differential effects of pharmacologic stressors: more than meets the eye.

Authors:  Philipp A Kaufmann
Journal:  J Nucl Cardiol       Date:  2006 May-Jun       Impact factor: 5.952

Review 5.  Role of PET in the evaluation and understanding of coronary physiology.

Authors:  Thomas H Schindler; Xiao-Li Zhang; Gabriella Vincenti; Leila Mhiri; René Lerch; Heinrich R Schelbert
Journal:  J Nucl Cardiol       Date:  2007-07       Impact factor: 5.952

6.  Assessment of myocardial perfusion by dynamic O-15-labeled water PET imaging: validation of a new fast factor analysis.

Authors:  Itaru Adachi; Oliver Gaemperli; Ines Valenta; Tiziano Schepis; Patrick T Siegrist; Valerie Treyer; Cyrill Burger; Koichi Morita; Philipp A Kaufmann
Journal:  J Nucl Cardiol       Date:  2007 Sep-Oct       Impact factor: 5.952

7.  Examiner repeatability of patellar cartilage T2 values.

Authors:  Matthew F Koff; Sebastien Parratte; Kimberly K Amrami; Kenton R Kaufman
Journal:  Magn Reson Imaging       Date:  2008-09-17       Impact factor: 2.546

8.  Protocol for measuring myocardial blood flow by PET/CT in cats.

Authors:  Simone D Jenni; Tiziano Schepis; Rolf Jenni; Patrick T Siegrist; Philipp A Kaufmann; Tony M Glaus
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-09-26       Impact factor: 9.236

9.  Coronary calcium score scans for attenuation correction of quantitative PET/CT 13N-ammonia myocardial perfusion imaging.

Authors:  Nina Burkhard; Bernhard A Herzog; Lars Husmann; Aju P Pazhenkottil; Irene A Burger; Ronny R Buechel; Ines Valenta; Christophe A Wyss; Philipp A Kaufmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-09-23       Impact factor: 9.236

10.  Repeatability of regional myocardial blood flow calculation in 82Rb PET imaging.

Authors:  Karin Knešaurek; Josef Machac; Zhuangyu Zhang
Journal:  BMC Med Phys       Date:  2009-01-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.