Literature DB >> 17318551

Three-dimensional stress analysis of threaded cups - a finite element analysis.

U Witzel1, W Rieger, H Effenberger.   

Abstract

A three-dimensional model of the left acetabulum with inserted threaded cup has been generated, based on the finite element method, to calculate stress patterns in the standing phase during walking. In this study, a hemispherical cup with sharp threads, a parabolic cup with flat threads and a conical cup with sharp threads were analysed and compared. Stress patterns in both implant components and adjacent bony structures were calculated in a directly postoperative situation. The different cups were found to induce different stress patterns, deformations and shifting tendencies. The inlays deform notably and show characteristic rotational movement patterns together with the shell. The inclination angle increases in the hemispherical cup and decreases in the parabolic cup. The conical cup levers outward almost parallel to the bone stock by approximately 0.05 mm. The pole surfaces of the various cups - especially the very convex area next to the threads - induce increased compressive stress in the superior section of the acetabular base. This is increased by a factor of three in the conical cup in comparison to the hemispherical cup and less so in comparison to the parabolic cup. This study illustrates that three-dimensional stress calculations are suitable for procuring additional biomechanical information to augment clinical studies, for evaluating implants and for establishing stability prognoses, especially for newly developed prototypes.

Entities:  

Mesh:

Year:  2007        PMID: 17318551      PMCID: PMC2269023          DOI: 10.1007/s00264-006-0308-3

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  14 in total

1.  Experimental study of bone-implant contact with a parabolic acetabular component (Hofer-Imhof).

Authors:  H Effenberger; G Böhm; M Huber; F Lintner; H Hofer
Journal:  Arch Orthop Trauma Surg       Date:  2000       Impact factor: 3.067

2.  [Thread design of screw-in acetabulum prostheses].

Authors:  H Effenberger; M Imhof; U Witzel
Journal:  Z Orthop Ihre Grenzgeb       Date:  2001 Sep-Oct

3.  A 10-year minimum follow-up of hydroxyapatite-coated threaded cups: clinical, radiographic and survivorship analyses with comparison to the literature.

Authors:  Jean-Alain Epinette; Michael T Manley; James A D'Antonio; Avram A Edidin; William N Capello
Journal:  J Arthroplasty       Date:  2003-02       Impact factor: 4.757

4.  Redesigned threaded, double-cone titanium cups yield excellent mid-term results. Counterpoint.

Authors:  Karl Zweymüller
Journal:  Orthopedics       Date:  2006-09       Impact factor: 1.390

5.  Cementless total hip arthroplasty with a tapered, rectangular titanium stem and a threaded cup: a minimum ten-year follow-up.

Authors:  Alexander Grübl; Catharina Chiari; Martin Gruber; Alexandra Kaider; Florian Gottsauner-Wolf
Journal:  J Bone Joint Surg Am       Date:  2002-03       Impact factor: 5.284

6.  Finite element analysis of acetabular reconstruction. Noncemented threaded cups.

Authors:  R Huiskes
Journal:  Acta Orthop Scand       Date:  1987-12

7.  Histological and radiographic assessment of well functioning porous-coated acetabular components. A human postmortem retrieval study.

Authors:  C A Engh; K F Zettl-Schaffer; Y Kukita; D Sweet; M Jasty; C Bragdon
Journal:  J Bone Joint Surg Am       Date:  1993-06       Impact factor: 5.284

8.  Computer simulations of stress-related bone remodeling around noncemented acetabular components.

Authors:  M E Levenston; G S Beaupré; D J Schurman; D R Carter
Journal:  J Arthroplasty       Date:  1993-12       Impact factor: 4.757

9.  Long-term results with the cementless Alloclassic brand hip arthroplasty system.

Authors:  Herwig Pieringer; Vinzenz Auersperg; Walter Griessler; Nikolaus Böhler
Journal:  J Arthroplasty       Date:  2003-04       Impact factor: 4.757

10.  Factors influencing the revision rate of Zweymueller acetabular cup.

Authors:  H Effenberger; T Ramsauer; U Dorn; M Imhof
Journal:  Int Orthop       Date:  2004-03-31       Impact factor: 3.075

View more
  2 in total

1.  Upward and inward displacements of the acetabular component increase stress on femoral head in single endoprothesis models.

Authors:  Zhiqi Zhang; Ming Fu; Yan Kang; Yi Chen; Weiming Liao
Journal:  Int Orthop       Date:  2009-05-08       Impact factor: 3.075

2.  Failure of Polyethylene Inlays in Cementless Total Hip Arthroplasty: A Retrieval Analysis.

Authors:  Ulrike Mueller; Christoph Lee; Christian Heisel; Marc Thomsen; Rudi G Bitsch; J Philippe Kretzer
Journal:  Biomed Res Int       Date:  2016-08-31       Impact factor: 3.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.