Literature DB >> 12629602

A 10-year minimum follow-up of hydroxyapatite-coated threaded cups: clinical, radiographic and survivorship analyses with comparison to the literature.

Jean-Alain Epinette1, Michael T Manley, James A D'Antonio, Avram A Edidin, William N Capello.   

Abstract

We evaluated the clinical, radiographic, and survivorship outcomes in a series of 418 threaded hydroxyapatite-coated acetabular cups (Arc2f; Osteonics, Allendale, NJ) implanted in a consecutive series of 384 patients undergoing primary total hip arthroplasty. In all cases, the cup was screwed into the prepared acetabulum. Bone screws were used to provide secondary fixation. At a minimum 10-year follow-up, 304 cups were available for analysis. The cumulative survivorship (mechanical failure as endpoint) at that time was 99.43% +/- 0.0104. Two hundred seventy-six hips were available for full clinical and radiographic review at or after the tenth anniversary. No unstable implants were noted; all implant fixation interfaces were classified as "stable bone ingrown," and the cup migration rate was zero. Based on the survivorship achieved with this implant, our results compare favorably with survivorship reported for the best cemented and cementless acetabular implant designs. Copyright 2003, Elsevier Science (USA). All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12629602     DOI: 10.1054/arth.2003.50039

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  8 in total

1.  The dual mobility socket concept: experience with 668 cases.

Authors:  Claude Vielpeau; Benoit Lebel; Ludovic Ardouin; Gilles Burdin; Christine Lautridou
Journal:  Int Orthop       Date:  2010-12-24       Impact factor: 3.075

2.  Three-dimensional stress analysis of threaded cups - a finite element analysis.

Authors:  U Witzel; W Rieger; H Effenberger
Journal:  Int Orthop       Date:  2007-02-21       Impact factor: 3.075

3.  Long-term results of the Wagner conical screw cup.

Authors:  Alexander Schuh; Annemarie Schraml; Gerd Hohenberger
Journal:  Int Orthop       Date:  2008-06-26       Impact factor: 3.075

4.  Case reports: fractures of threaded cups: rare complications of a well-established implant.

Authors:  Arnd T Hoburg; Manav Mehta; Stephan Tohtz; Carsten Perka
Journal:  Clin Orthop Relat Res       Date:  2008-09-27       Impact factor: 4.176

5.  Factors influencing the revision rate of Zweymueller acetabular cup.

Authors:  H Effenberger; T Ramsauer; U Dorn; M Imhof
Journal:  Int Orthop       Date:  2004-03-31       Impact factor: 3.075

6.  Engineering endochondral bone: in vitro studies.

Authors:  Serafim M Oliveira; Isabel F Amaral; Mário A Barbosa; Cristina C Teixeira
Journal:  Tissue Eng Part A       Date:  2009-03       Impact factor: 3.845

7.  Cementless hydroxyapatite coated hip prostheses.

Authors:  Antonio Herrera; Jesús Mateo; Jorge Gil-Albarova; Antonio Lobo-Escolar; Elena Ibarz; Sergio Gabarre; Yolanda Más; Luis Gracia
Journal:  Biomed Res Int       Date:  2015-02-23       Impact factor: 3.411

Review 8.  Dental Implant Bioactive Surface Modifiers: An Update.

Authors:  Osamah Mohammed Al Mugeiren; Mohammad Abdul Baseer
Journal:  J Int Soc Prev Community Dent       Date:  2019-02-14
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.