OBJECTIVES: To validate a new device (PiCCO system; Pulsion Medical Systems, Munich, Germany), we compared cardiac index derived from transpulmonary thermodilution and from pulse contour analysis in pediatric patients after surgery for congenital heart disease. We performed a prospective clinical study in a pediatric cardiac intensive care unit of a university hospital.
METHODS: Twenty-four patients who had had cardiac surgery for congenital heart disease (median age 4.2 years, range 1.4-15.2 years) were investigated in the first 24 hours after admission to the intensive care unit. A 3F thermodilution catheter was inserted in the femoral artery. Intracardiac shunts were excluded by echocardiography intraoperatively or postoperatively. Cardiac index derived from pulse contour analysis was documented in each patient 1, 4, 8, 12, 16, 20, and 24 hours after admission to the intensive care unit. Subsequently, a set of three measurements of thermodilution cardiac indices derived by injections into a central venous line was performed and calculated by the PiCCO system.
RESULTS: The mean bias between cardiac indices derived by thermodilution and those derived by pulse contour analysis over all data points was 0.05 (SD 0.4) L x min x m(-2) (95% confidence interval 0.01-0.10). A strong correlation between thermodilution and contour analysis cardiac indices was calculated (Pearson correlation coefficient r = 0.93; coefficient of determination r2 = 0.86).
CONCLUSIONS: Pulse contour analysis is a suitable method to monitor cardiac index over a wide range of indices after surgery for congenital heart disease in pediatric patients. Pulse contour analysis allows online monitoring of cardiac index. The PiCCO device can be recalibrated with the integrated transpulmonary thermodilution within a short time frame.

Entities:  

Mesh:

Year:  2007        PMID: 17198817     DOI: 10.1016/j.jtcvs.2006.07.038

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  11 in total

1.  Transpulmonary thermodilution in neonates undergoing arterial switch surgery.

Authors:  Andrea Székely; Tamás Breuer; Erzsébet Sápi; Edgár Székely; András Szatmári; Miklós Tóth; Balázs Hauser; János Gál
Journal:  Pediatr Cardiol       Date:  2011-02       Impact factor: 1.655

Review 2.  Accuracy and precision of minimally-invasive cardiac output monitoring in children: a systematic review and meta-analysis.

Authors:  Koichi Suehiro; Alexandre Joosten; Linda Suk-Ling Murphy; Olivier Desebbe; Brenton Alexander; Sang-Hyun Kim; Maxime Cannesson
Journal:  J Clin Monit Comput       Date:  2015-08-29       Impact factor: 2.502

3.  Transpulmonary Thermodilution Versus Transthoracic Echocardiography for Cardiac Output Measurements in Severely Burned Children.

Authors:  Paul Wurzer; Ludwik K Branski; Marc G Jeschke; Arham Ali; Michael P Kinsky; Fredrick J Bohanon; Gabriel Hundeshagen; William B Norbury; Felicia N Williams; Lars-P Kamolz; Celeste C Finnerty; David N Herndon
Journal:  Shock       Date:  2016-09       Impact factor: 3.454

4.  Validation of a new method based on ultrasound velocity dilution to measure cardiac output in paediatric patients.

Authors:  Alejandro A Floh; Gustavo La Rotta; Julius Z Wermelt; Patricia Bastero-Miñón; V Ben Sivarajan; Tilman Humpl
Journal:  Intensive Care Med       Date:  2013-02-22       Impact factor: 17.440

5.  Influence of patent ductus arteriosus and ventilators on electrical velocimetry for measuring cardiac output in very-low/low birth weight infants.

Authors:  T Torigoe; S Sato; Y Nagayama; T Sato; H Yamazaki
Journal:  J Perinatol       Date:  2015-01-29       Impact factor: 2.521

6.  Transpulmonary thermodilution in a pediatric patient with an intracardiac left-to-right shunt.

Authors:  Geoffray Keller; Olivier Desebbe; Roland Henaine; Jean-Jacques Lehot
Journal:  J Clin Monit Comput       Date:  2011-06-09       Impact factor: 2.502

Review 7.  [Hemodynamic monitoring in pediatric anesthesia].

Authors:  Andreas Otte; Ehrenfried Schindler; Claudia Neumann
Journal:  Anaesthesiologie       Date:  2022-05-23

Review 8.  Advances in monitoring and management of shock.

Authors:  Haifa Mtaweh; Erin V Trakas; Erik Su; Joseph A Carcillo; Rajesh K Aneja
Journal:  Pediatr Clin North Am       Date:  2013-03-29       Impact factor: 3.278

9.  Trending ability and limitations of transpulmonary thermodilution and pulse contour cardiac output measurement in cats as a model for pediatric patients.

Authors:  Annette P N Kutter; Rima N Bektas; Christoph K Hofer; M Paula Larenza Menzies; Regula Bettschart-Wolfensberger
Journal:  J Clin Monit Comput       Date:  2014-09-17       Impact factor: 2.502

Review 10.  Cardiac Output Monitoring in Preterm Infants.

Authors:  Matthew McGovern; Jan Miletin
Journal:  Front Pediatr       Date:  2018-04-03       Impact factor: 3.418

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.