Accuracy and precision of minimally-invasive cardiac output monitoring in children: a systematic review and meta-analysis.

Koichi Suehiro1,2, Alexandre Joosten3,4, Linda Suk-Ling Murphy5, Olivier Desebbe3,6, Brenton Alexander3, Sang-Hyun Kim3,7, Maxime Cannesson3.   

Abstract

Several minimally-invasive technologies are available for cardiac output (CO) measurement in children, but the accuracy and precision of these devices have not yet been evaluated in a systematic review and meta-analysis. We conducted a comprehensive search of the medical literature in PubMed, Cochrane Library of Clinical Trials, Scopus, and Web of Science from its inception to June 2014 assessing the accuracy and precision of all minimally-invasive CO monitoring systems used in children when compared with CO monitoring reference methods. Pooled mean bias, standard deviation, and mean percentage error of included studies were calculated using a random-effects model. The inter-study heterogeneity was also assessed using an I(2) statistic. A total of 20 studies (624 patients) were included. The overall random-effects pooled bias, and mean percentage error were 0.13 ± 0.44 l min(-1) and 29.1 %, respectively. Significant inter-study heterogeneity was detected (P < 0.0001, I(2) = 98.3 %). In the sub-analysis regarding the device, electrical cardiometry showed the smallest bias (-0.03 l min(-1)) and lowest percentage error (23.6 %). Significant residual heterogeneity remained after conducting sensitivity and subgroup analyses based on the various study characteristics. By meta-regression analysis, we found no independent effects of study characteristics on weighted mean difference between reference and tested methods. Although the pooled bias was small, the mean pooled percentage error was in the gray zone of clinical applicability. In the sub-group analysis, electrical cardiometry was the device that provided the most accurate measurement. However, a high heterogeneity between studies was found, likely due to a wide range of study characteristics.

Entities:  

Keywords:  Accuracy; Cardiac output; Children; Hemodynamic monitoring; Meta-analysis

Mesh:

Year:  2015        PMID: 26315477     DOI: 10.1007/s10877-015-9757-9

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  77 in total

Review 1.  Accuracy of continuous noninvasive hemoglobin monitoring: a systematic review and meta-analysis.

Authors:  Sang-Hyun Kim; Marc Lilot; Linda Suk-Ling Murphy; Kulraj S Sidhu; Zhaoxia Yu; Joseph Rinehart; Maxime Cannesson
Journal:  Anesth Analg       Date:  2014-08       Impact factor: 5.108

2.  Comparison of transpulmonary thermodilution, transthoracic echocardiography and conventional hemodynamic monitoring in neonates and infants after open heart surgery: a preliminary study.

Authors:  M Gergely; L Ablonczy; S Kramer; E A Székely; E Sápi; J Gál; A Szatmári; A Székely
Journal:  Minerva Anestesiol       Date:  2012-10       Impact factor: 3.051

3.  Electrical velocimetry as a tool for measuring cardiac output in small infants after heart surgery.

Authors:  Oswin Grollmuss; Serge Demontoux; André Capderou; Alain Serraf; Emre Belli
Journal:  Intensive Care Med       Date:  2012-03-30       Impact factor: 17.440

4.  An evaluation of a noninvasive cardiac output measurement using partial carbon dioxide rebreathing in children.

Authors:  Richard J Levy; Rosetta M Chiavacci; Susan C Nicolson; Jonathan J Rome; Richard J Lin; Mark A Helfaer; Vinay M Nadkarni
Journal:  Anesth Analg       Date:  2004-12       Impact factor: 5.108

5.  Arterial pulse wave analysis: An accurate means of determining cardiac output in children.

Authors:  Jeffrey J Kim; W Jeffrey Dreyer; Anthony C Chang; John P Breinholt; Ronald G Grifka
Journal:  Pediatr Crit Care Med       Date:  2006-11       Impact factor: 3.624

6.  Noninvasive cardiac output measurement using bioreactance in postoperative pediatric patients.

Authors:  Estelle Vergnaud; Charles Vidal; Juliette Montmayeur Verchere; Hanna Taright; Philippe G Meyer; Pierre A Carli; Gilles A Orliaguet
Journal:  Paediatr Anaesth       Date:  2014-05-12       Impact factor: 2.556

7.  Hemodynamic support in fluid-refractory pediatric septic shock.

Authors:  G Ceneviva; J A Paschall; F Maffei; J A Carcillo
Journal:  Pediatrics       Date:  1998-08       Impact factor: 7.124

8.  Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery.

Authors:  Tong J Gan; Andrew Soppitt; Mohamed Maroof; Habib el-Moalem; Kerri M Robertson; Eugene Moretti; Peter Dwane; Peter S A Glass
Journal:  Anesthesiology       Date:  2002-10       Impact factor: 7.892

9.  Pressure recording analytical method and bioreactance for stroke volume index monitoring during pediatric cardiac surgery.

Authors:  Cristiana Garisto; Isabella Favia; Zaccaria Ricci; Stefano Romagnoli; Roberta Haiberger; Angelo Polito; Paola Cogo
Journal:  Paediatr Anaesth       Date:  2014-02-03       Impact factor: 2.556

Review 10.  Continuous measurement of cardiac output by the Fick principle in infants and children: comparison with the thermodilution method.

Authors:  C F Wippermann; R G Huth; F X Schmidt; J Thul; M Betancor; D Schranz
Journal:  Intensive Care Med       Date:  1996-05       Impact factor: 17.440

View more
  22 in total

1.  Does obesity affect the non-invasive measurement of cardiac output performed by electrical cardiometry in children and adolescents?

Authors:  Luis Altamirano-Diaz; Eva Welisch; Ralf Rauch; Michael Miller; Teresa Sohee Park; Kambiz Norozi
Journal:  J Clin Monit Comput       Date:  2017-02-17       Impact factor: 2.502

2.  Accuracy and precision of non-invasive cardiac output monitoring by electrical cardiometry: a systematic review and meta-analysis.

Authors:  M Sanders; S Servaas; C Slagt
Journal:  J Clin Monit Comput       Date:  2019-06-07       Impact factor: 2.502

Review 3.  Journal of Clinical Monitoring and Computing 2016 end of year summary: cardiovascular and hemodynamic monitoring.

Authors:  Bernd Saugel; Karim Bendjelid; Lester A Critchley; Steffen Rex; Thomas W L Scheeren
Journal:  J Clin Monit Comput       Date:  2017-01-07       Impact factor: 2.502

4.  Effect of patent ductus arteriosus and patent foramen ovale on left ventricular stroke volume measurement by electrical velocimetry in comparison to transthoracic echocardiography in neonates.

Authors:  Martin Ernst Blohm; Jana Hartwich; Denise Obrecht; Jan Felix Kersten; Dominique Singer
Journal:  J Clin Monit Comput       Date:  2016-04-12       Impact factor: 2.502

5.  Pre-anesthetic stroke volume variation can predict cardiac output decrease and hypotension during induction of general anesthesia.

Authors:  Takashi Juri; Koichi Suehiro; Sayaka Tsujimoto; Shigemune Kuwata; Akira Mukai; Katsuaki Tanaka; Tokuhiro Yamada; Takashi Mori; Kiyonobu Nishikawa
Journal:  J Clin Monit Comput       Date:  2017-06-24       Impact factor: 2.502

6.  Carotid Doppler Ultrasonography for Hemodynamic Assessment in Critically Ill Children.

Authors:  Aline Junqueira Rubio; Luiza Lobo de Souza; Roberto J N Nogueira; Marcelo B Brandão; Tiago H de Souza
Journal:  Pediatr Cardiol       Date:  2021-09-13       Impact factor: 1.655

Review 7.  [Hemodynamic monitoring in pediatric anesthesia].

Authors:  Andreas Otte; Ehrenfried Schindler; Claudia Neumann
Journal:  Anaesthesiologie       Date:  2022-05-23

8.  Hydroxyethyl starch 130/0.4 versus crystalloid co-loading during general anesthesia induction: a randomized controlled trial.

Authors:  Takashi Juri; Koichi Suehiro; Shigemune Kuwata; Sayaka Tsujimoto; Akira Mukai; Katsuaki Tanaka; Tokuhiro Yamada; Takashi Mori; Kiyonobu Nishikawa
Journal:  J Anesth       Date:  2017-10-25       Impact factor: 2.078

9.  Babies and Children at Last: Pediatric Cardiac Output Monitoring in the Twenty-first Century.

Authors:  Christine T Trieu; Tiffany M Williams; Maxime Cannesson; Jure Marijic
Journal:  Anesthesiology       Date:  2019-05       Impact factor: 8.986

Review 10.  Cardiac Output Monitoring in Preterm Infants.

Authors:  Matthew McGovern; Jan Miletin
Journal:  Front Pediatr       Date:  2018-04-03       Impact factor: 3.418

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.