Literature DB >> 27058051

Transpulmonary Thermodilution Versus Transthoracic Echocardiography for Cardiac Output Measurements in Severely Burned Children.

Paul Wurzer1, Ludwik K Branski, Marc G Jeschke, Arham Ali, Michael P Kinsky, Fredrick J Bohanon, Gabriel Hundeshagen, William B Norbury, Felicia N Williams, Lars-P Kamolz, Celeste C Finnerty, David N Herndon.   

Abstract

INTRODUCTION: Severe burns trigger a hyperdynamic state, necessitating accurate measurement of cardiac output (CO) for cardiovascular observation and guiding fluid resuscitation. However, it is unknown whether, in burned children, the increasingly popular transthoracic echocardiography (TTE) method of CO measurement is as accurate as the widely used transpulmonary thermodilution (TPTD) method. PATIENTS AND METHODS: We retrospectively compared near-simultaneously performed CO measurements in severely burned children using TPTD with the Pulse index Continuous Cardiac Output (PiCCO) system or TTE. Outcomes were compared using t tests, multiple linear regression, and a Bland-Altman plot.
RESULTS: Fifty-four children (9 ± 5 years) with 68 ± 18% total body surface area burns were studied. An analysis of 105 data pairs revealed that PiCCO yielded higher CO measurements than TTE (190 ± 39% vs. 150 ± 50% predicted values; P < 0.01). PiCCO- and TTE-derived CO measurements correlated moderately well (R = 0.54, P < 0.01). A Bland-Altman plot showed a mean bias of 1.53 L/min with a 95% prediction interval of 4.31 L/min.
CONCLUSIONS: TTE-derived estimates of CO may underestimate severity of the hyperdynamic state in severely burned children. We propose using the PiCCO system for objective cardiovascular monitoring and to guide goal-directed fluid resuscitation in this population.

Entities:  

Mesh:

Year:  2016        PMID: 27058051      PMCID: PMC4987178          DOI: 10.1097/SHK.0000000000000627

Source DB:  PubMed          Journal:  Shock        ISSN: 1073-2322            Impact factor:   3.454


  33 in total

1.  Cardiac output and related measurements and pressure values in the right heart and associated vessels, together with an analysis of the hemo-dynamic response to the inhalation of high oxygen mixtures in healthy subjects.

Authors:  B G BARRATT-BOYES; E H WOOD
Journal:  J Lab Clin Med       Date:  1958-01

2.  Effects of thermal trauma on cardiac force of contraction.

Authors:  J G Hilton; D S Marullo
Journal:  Burns Incl Therm Inj       Date:  1986-02

3.  Burn-induced cardiac dysfunction increases length of stay in pediatric burn patients.

Authors:  Taylor S Howard; Daniel G Hermann; Alexis L McQuitty; Lee C Woodson; George C Kramer; David N Herndon; Paul M Ford; Michael P Kinsky
Journal:  J Burn Care Res       Date:  2013 Jul-Aug       Impact factor: 1.845

Review 4.  Survival from burns in the new millennium: 70 years' experience from a single institution.

Authors:  Ronald G Tompkins
Journal:  Ann Surg       Date:  2015-02       Impact factor: 12.969

5.  Prognostic significance of left ventricular diastolic function in burn patients.

Authors:  Chih-Yun Lin; Cho-Kai Wu; Eng-Kean Yeong; Heng-Hsu Lin; Yin-Tsen Huang; Jen-Kuang Lee; Yu-Hsun Lin; Fu-Tien Chiang; Yueh-Bih Tang; Chia-Ti Tsai
Journal:  Shock       Date:  2012-05       Impact factor: 3.454

6.  Current expectations for survival in pediatric burns.

Authors:  R L Sheridan; J P Remensnyder; J J Schnitzer; J T Schulz; C M Ryan; R G Tompkins
Journal:  Arch Pediatr Adolesc Med       Date:  2000-03

Review 7.  Ultrasonography for haemodynamic monitoring.

Authors:  Jens M Poth; Daniel R Beck; Karsten Bartels
Journal:  Best Pract Res Clin Anaesthesiol       Date:  2014-09-07

8.  Transpulmonary thermodilution for hemodynamic measurements in severely burned children.

Authors:  Ludwik K Branski; David N Herndon; Jaron F Byrd; Michael P Kinsky; Jong O Lee; Shawn P Fagan; Marc G Jeschke
Journal:  Crit Care       Date:  2011-04-21       Impact factor: 9.097

Review 9.  Clinical review: Does it matter which hemodynamic monitoring system is used?

Authors:  Davinder Ramsingh; Brenton Alexander; Maxime Cannesson
Journal:  Crit Care       Date:  2013-03-05       Impact factor: 9.097

10.  A protocol for resuscitation of severe burn patients guided by transpulmonary thermodilution and lactate levels: a 3-year prospective cohort study.

Authors:  Manuel Sánchez; Abelardo García-de-Lorenzo; Eva Herrero; Teresa Lopez; Beatriz Galvan; María Asensio; Lucia Cachafeiro; Cesar Casado
Journal:  Crit Care       Date:  2013-08-15       Impact factor: 9.097

View more
  8 in total

1.  The P50 Research Center in Perioperative Sciences: How the investment by the National Institute of General Medical Sciences in team science has reduced postburn mortality.

Authors:  Celeste C Finnerty; Karel D Capek; Charles Voigt; Gabriel Hundeshagen; Janos Cambiaso-Daniel; Craig Porter; Linda E Sousse; Amina El Ayadi; Ramon Zapata-Sirvent; Ashley N Guillory; Oscar E Suman; David N Herndon
Journal:  J Trauma Acute Care Surg       Date:  2017-09       Impact factor: 3.313

Review 2.  Volume Resuscitation in Patients With High-Voltage Electrical Injuries.

Authors:  Derek M Culnan; Kelley Farner; Genevieve H Bitz; Karel D Capek; Yiji Tu; Carlos Jimenez; William C Lineaweaver
Journal:  Ann Plast Surg       Date:  2018-03       Impact factor: 1.539

3.  Propranolol Reduces Cardiac Index But does not Adversely Affect Peripheral Perfusion in Severely Burned Children.

Authors:  Paul Wurzer; Ludwik K Branski; Robert P Clayton; Gabriel Hundeshagen; Abigail A Forbes; Charles D Voigt; Clark R Andersen; Lars-P Kamolz; Lee C Woodson; Oscar E Suman; Celeste C Finnerty; David N Herndon
Journal:  Shock       Date:  2016-11       Impact factor: 3.454

4.  Noninvasive Cardiac Output Monitoring Using Electrical Cardiometry and Outcomes in Critically Ill Children.

Authors:  Lydia Sumbel; Muthiah R Annamalai; Aanchal Wats; Mohammed Salameh; Arpit Agarwal; Utpal Bhalala
Journal:  J Pediatr Intensive Care       Date:  2020-11-19

Review 5.  [Hemodynamic monitoring in pediatric anesthesia].

Authors:  Andreas Otte; Ehrenfried Schindler; Claudia Neumann
Journal:  Anaesthesiologie       Date:  2022-05-23

6.  Effect of Pulse Indicator Continuous Cardiac Output Monitoring on Septic Shock Patients: A Meta-Analysis.

Authors:  Bin Wang; Lijuan Cai; Bin Lin; Qiongxiao He; Xuejun Ding
Journal:  Comput Math Methods Med       Date:  2022-04-16       Impact factor: 2.809

7.  Comparison of cardiac output and cardiac index values measured by critical care echocardiography with the values measured by pulse index continuous cardiac output (PiCCO) in the pediatric intensive care unit:a preliminary study.

Authors:  Nagehan Aslan; Dincer Yildizdas; Ozden Ozgur Horoz; Yasemin Coban; Fadli Demir; Sevcan Erdem; Yasar Sertdemir
Journal:  Ital J Pediatr       Date:  2020-04-16       Impact factor: 2.638

8.  Recommendations for hemodynamic monitoring for critically ill children-expert consensus statement issued by the cardiovascular dynamics section of the European Society of Paediatric and Neonatal Intensive Care (ESPNIC).

Authors:  Yogen Singh; Javier Urbano Villaescusa; Eduardo M da Cruz; Shane M Tibby; Gabriella Bottari; Rohit Saxena; Marga Guillén; Jesus Lopez Herce; Matteo Di Nardo; Corrado Cecchetti; Joe Brierley; Willem de Boode; Joris Lemson
Journal:  Crit Care       Date:  2020-10-22       Impact factor: 9.097

  8 in total