Literature DB >> 20020135

Cementless total hip arthroplasty in patients with rheumatoid arthritis using a tapered designed titanium hip stem minimum: 10-year results.

Hans D Carl1, Jan Ploetzner, Bernd Swoboda, Gerd Weseloh, Lutz Arne Mueller.   

Abstract

The results of cementless tapered designed femoral stem were studied at a minimum 10-year follow-up in a non-selected, consecutive group of 27 patients (39 hips) with rheumatoid arthritis. Clinical and radiological analyses were performed in 27 hips, 17 patients (mean age at surgery 45 years) after a mean of 12 years. The postoperative Harris hip score was excellent for 14 hips, 9 hips were rated as good and 4 hips were fair or poor. No stem had to be revised for aseptic loosening. Proximal stress shielding was observed in 26 hips (96%); heterotopic ossification was present in 11 hips (41%). Six hips required revision of the acetabular component. With uncemented tapered femoral fixation excellent 12-year results are achieved in patients with rheumatoid arthritis.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20020135     DOI: 10.1007/s00296-009-1300-1

Source DB:  PubMed          Journal:  Rheumatol Int        ISSN: 0172-8172            Impact factor:   2.631


  39 in total

1.  Minimum 10-year results of a tapered, titanium, hydroxyapatite-coated hip stem: an independent review.

Authors:  Mark I Froimson; Jonathan Garino; Alan Machenaud; J P Vidalain
Journal:  J Arthroplasty       Date:  2007-01       Impact factor: 4.757

2.  Total hip arthroplasty using porous-coated femoral components in patients with rheumatoid arthritis.

Authors:  A K Jana; C A Engh; P J Lewandowski; R H Hopper; C A Engh
Journal:  J Bone Joint Surg Br       Date:  2001-07

3.  Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results.

Authors:  C A Engh; J D Bobyn; A H Glassman
Journal:  J Bone Joint Surg Br       Date:  1987-01

4.  The transgluteal approach to the hip joint.

Authors:  R Bauer; F Kerschbaumer; S Poisel; W Oberthaler
Journal:  Arch Orthop Trauma Surg       Date:  1979-10

5.  Ectopic ossification following total hip replacement. Incidence and a method of classification.

Authors:  A F Brooker; J W Bowerman; R A Robinson; L H Riley
Journal:  J Bone Joint Surg Am       Date:  1973-12       Impact factor: 5.284

6.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

Authors:  T A Gruen; G M McNeice; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

7.  Long-term follow-up of cemented total hip arthroplasty in rheumatoid arthritis.

Authors:  R Severt; R Wood; A Cracchiolo; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1991-04       Impact factor: 4.176

8.  Periarticular bone in rheumatoid arthritis versus arthrosis. Histomorphometry in 103 hip biopsies.

Authors:  K Akesson; I Onsten; K J Obrant
Journal:  Acta Orthop Scand       Date:  1994-04

Review 9.  The impact of total joint replacement in rheumatoid arthritis.

Authors:  Rob G H H Nelissen
Journal:  Best Pract Res Clin Rheumatol       Date:  2003-10       Impact factor: 4.098

10.  Excellent results of HA coating on a grit-blasted stem: 245 patients followed for 8-12 years.

Authors:  Olav Reikerås; Ragnhild B Gunderson
Journal:  Acta Orthop Scand       Date:  2003-04
View more
  2 in total

Review 1.  [Large-joint synovectomy in the era of biological therapies].

Authors:  H-D Carl; J Rech
Journal:  Z Rheumatol       Date:  2011-01       Impact factor: 1.372

2.  Cementless total hip arthroplasty for patients with rheumatoid arthritis: a more than 10-year follow-up.

Authors:  Takahito Yuasa; Katsuhiko Maezawa; Masahiko Nozawa; Kazuo Kaneko
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-06-16
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.