Literature DB >> 17153411

Characterization of scattered radiation in kV CBCT images using Monte Carlo simulations.

Geneviève Jarry1, Sean A Graham, Douglas J Moseley, David J Jaffray, Jeffrey H Siewerdsen, Frank Verhaegen.   

Abstract

Kilovoltage (kV) cone beam computed tomography (CBCT) images suffer from a substantial scatter contribution. In this study, Monte Carlo (MC) simulations are used to evaluate the scattered radiation present in projection images. These predicted scatter distributions are also used as a scatter correction technique. Images were acquired using a kV CBCT bench top system. The EGSnrc MC code was used to model the flat panel imager, the phantoms, and the x-ray source. The x-ray source model was validated using first and second half-value layers (HVL) and profile measurements. The HVLs and the profile were found to agree within 3% and 6%, respectively. MC simulated and measured projection images for a cylindrical water phantom and for an anthropomorphic head phantom agreed within 8% and 10%. A modified version of the DOSXYZnrc MC code was used to score phase space files with identified scattered and primary particles behind the phantoms. The cone angle, the source-to-detector distance, the phantom geometry, and the energy were varied to determine their effect on the scattered radiation distribution. A scatter correction technique was developed in which the MC predicted scatter distribution is subtracted from the projections prior to reconstruction. Preliminary testing of the procedure was done with an anthropomorphic head phantom and a contrast phantom. Contrast and profile measurements were obtained for the scatter corrected and noncorrected images. An improvement of 3% for contrast between solid water and a liver insert and 11% between solid water and a Teflon insert were obtained and a significant reduction in cupping and streaking artifacts was observed.

Entities:  

Mesh:

Year:  2006        PMID: 17153411     DOI: 10.1118/1.2358324

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  31 in total

1.  Characterization and correction of cupping effect artefacts in cone beam CT.

Authors:  A K Hunter; W D McDavid
Journal:  Dentomaxillofac Radiol       Date:  2012-03       Impact factor: 2.419

2.  Assessment of accuracy and efficiency of atlas-based autosegmentation for prostate radiotherapy in a variety of clinical conditions.

Authors:  I Simmat; P Georg; D Georg; W Birkfellner; G Goldner; M Stock
Journal:  Strahlenther Onkol       Date:  2012-06-07       Impact factor: 3.621

3.  Monte Carlo evaluation of scatter mitigation strategies in cone-beam CT.

Authors:  Dimitrios Lazos; Jeffrey F Williamson
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

4.  Noise suppression in scatter correction for cone-beam CT.

Authors:  Lei Zhu; Jing Wang; Lei Xing
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

5.  Scatter correction for cone-beam CT in radiation therapy.

Authors:  Lei Zhu; Yaoqin Xie; Jing Wang; Lei Xing
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

6.  Characterization of scatter magnitude and distribution in dedicated breast computed tomography with bowtie filters.

Authors:  Kimberly Kontson; Robert J Jennings
Journal:  J Med Imaging (Bellingham)       Date:  2014-12-18

7.  Single-scan patient-specific scatter correction in computed tomography using peripheral detection of scatter and compressed sensing scatter retrieval.

Authors:  Bowen Meng; Ho Lee; Lei Xing; Benjamin P Fahimian
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

8.  Monte Carlo study of the effects of system geometry and antiscatter grids on cone-beam CT scatter distributions.

Authors:  A Sisniega; W Zbijewski; A Badal; I S Kyprianou; J W Stayman; J J Vaquero; J H Siewerdsen
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

9.  Investigation into image quality and dose for different patient geometries with multiple cone-beam CT systems.

Authors:  Stephen J Gardner; Matthew T Studenski; Tawfik Giaddui; Yunfeng Cui; James Galvin; Yan Yu; Ying Xiao
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

10.  4D cone-beam computed tomography (CBCT) using a moving blocker for simultaneous radiation dose reduction and scatter correction.

Authors:  Cong Zhao; Yuncheng Zhong; Xinhui Duan; You Zhang; Xiaokun Huang; Jing Wang; Mingwu Jin
Journal:  Phys Med Biol       Date:  2018-05-29       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.