Literature DB >> 17151922

Image correlation algorithm for measuring lymphocyte velocity and diameter changes in contracting microlymphatics.

J Brandon Dixon1, Anatoliy A Gashev, David C Zawieja, James E Moore, Gerard L Coté.   

Abstract

Efforts have recently been made to estimate wall shear stress throughout the contractile cycle of mesenteric rat lymphatics with a high speed video microscopy system. This was prompted by reports in the literature that lymphatic pumping is related to wall shear stress. While one can estimate wall shear stress by tracking lymphocyte velocity, it is prohibitively tedious to manually track particles over a reasonable time frame for a good number of experiments. To overcome this, an image correlation method similar to digital particle imaging velocimetry was developed and tested on contracting lymphatics to measure both vessel diameter and fluid velocity. The program tracked temporal fluctuations in spatially averaged velocity with a standard error of prediction of 0.4 mm/s. From these studies we have measured velocities ranging from -2 to 4 mm/s. Diameter changes were also measured with a standard error of 7 microm. These algorithms and techniques could be beneficial for investigating various changes in contractile behavior as a function of changes in velocity and wall shear stress.

Entities:  

Mesh:

Year:  2006        PMID: 17151922      PMCID: PMC1989687          DOI: 10.1007/s10439-006-9225-2

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  7 in total

1.  Regional variations of contractile activity in isolated rat lymphatics.

Authors:  Anatoliy A Gashev; Michael J Davis; Michael D Delp; David C Zawieja
Journal:  Microcirculation       Date:  2004-09       Impact factor: 2.628

2.  Absolute cross-sectional area measurements in quantitative coronary arteriography by dual-energy DSA.

Authors:  S Y Molloi; A Ersahin; W W Roeck; O Nalcioglu
Journal:  Invest Radiol       Date:  1991-02       Impact factor: 6.016

3.  Measuring microlymphatic flow using fast video microscopy.

Authors:  J Brandon Dixon; David C Zawieja; Anatoliy A Gashev; Gerard L Coté
Journal:  J Biomed Opt       Date:  2005 Nov-Dec       Impact factor: 3.170

4.  An algorithm for angiographic estimation of blood vessel diameter.

Authors:  A V Clough; G S Krenz; M Owens; A al-Tinawi; C A Dawson; J H Linehan
Journal:  J Appl Physiol (1985)       Date:  1991-11

5.  Optimal sampling interval and edge detection algorithm for measurement of blood vessel diameter on a cineangiogram.

Authors:  C Uyama; Y Kita; S Matsusita
Journal:  Invest Radiol       Date:  1993-12       Impact factor: 6.016

6.  Inhibition of the active lymph pump by flow in rat mesenteric lymphatics and thoracic duct.

Authors:  Anatoliy A Gashev; Michael J Davis; David C Zawieja
Journal:  J Physiol       Date:  2002-05-01       Impact factor: 5.182

7.  Image correlation method for measuring blood flow velocity in microcirculation: correlation 'window' simulation and in vivo image analysis.

Authors:  K Tsukada; H Minamitani; E Sekizuka; C Oshio
Journal:  Physiol Meas       Date:  2000-11       Impact factor: 2.833

  7 in total
  24 in total

1.  Biofluid mechanics of special organs and the issue of system control. Sixth International Bio-Fluid Mechanics Symposium and Workshop, March 28-30, 2008 Pasadena, California.

Authors:  Mair Zamir; James E Moore; Hideki Fujioka; Donald P Gaver
Journal:  Ann Biomed Eng       Date:  2010-03       Impact factor: 3.934

2.  Measuring contraction propagation and localizing pacemaker cells using high speed video microscopy.

Authors:  Tony J Akl; Zhanna V Nepiyushchikh; Anatoliy A Gashev; David C Zawieja; Gerard L Cot
Journal:  J Biomed Opt       Date:  2011-02       Impact factor: 3.170

3.  The advection of microparticles, MCF-7 and MDA-MB-231 breast cancer cells in response to very low Reynolds numbers.

Authors:  Sinéad T Morley; Michael T Walsh; David T Newport
Journal:  Biomicrofluidics       Date:  2017-05-05       Impact factor: 2.800

4.  Sensitivity analysis of near-infrared functional lymphatic imaging.

Authors:  Michael Weiler; Timothy Kassis; J Brandon Dixon
Journal:  J Biomed Opt       Date:  2012-06       Impact factor: 3.170

Review 5.  Inflammation-induced lymphangiogenesis and lymphatic dysfunction.

Authors:  Shan Liao; Pierre-Yves von der Weid
Journal:  Angiogenesis       Date:  2014-01-22       Impact factor: 9.596

Review 6.  Lymphatic lipid transport: sewer or subway?

Authors:  J Brandon Dixon
Journal:  Trends Endocrinol Metab       Date:  2010-06-11       Impact factor: 12.015

7.  Lymph transport in rat mesenteric lymphatics experiencing edemagenic stress.

Authors:  Elaheh Rahbar; Tony Akl; Gerard L Coté; James E Moore; David C Zawieja
Journal:  Microcirculation       Date:  2014-07       Impact factor: 2.628

8.  Dual-channel in-situ optical imaging system for quantifying lipid uptake and lymphatic pump function.

Authors:  Timothy Kassis; Alison B Kohan; Michael J Weiler; Matthew E Nipper; Rachel Cornelius; Patrick Tso; J Brandon Dixon
Journal:  J Biomed Opt       Date:  2012-08       Impact factor: 3.170

9.  Contractile physiology of lymphatics.

Authors:  David C Zawieja
Journal:  Lymphat Res Biol       Date:  2009       Impact factor: 2.589

10.  A tissue-engineered model of the intestinal lacteal for evaluating lipid transport by lymphatics.

Authors:  J Brandon Dixon; Sandeep Raghunathan; Melody A Swartz
Journal:  Biotechnol Bioeng       Date:  2009-08-15       Impact factor: 4.530

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.