Literature DB >> 2055711

Absolute cross-sectional area measurements in quantitative coronary arteriography by dual-energy DSA.

S Y Molloi1, A Ersahin, W W Roeck, O Nalcioglu.   

Abstract

Recent studies have emphasized the limitations of conventional coronary angiography. These limitations include the lack of correlation between the severity of coronary stenosis as estimated from coronary angiograms and the actual severity of stenotic lesions measured in postmortem hearts. As a result, attempts have been made to quantitate luminal dimension more precisely. The application of quantitative digital subtraction angiography (DSA) in the assessment of coronary artery lesion dimension has been limited by cardiac and respiratory motion artifacts. We have reported previously on a motion-immune dual-energy (DE) cardiac mode in which kVp and filtration are switched at 30 Hz. To assess the potential advantages of a videodensitometric technique for quantification of absolute vessel cross-sectional area (CSA), three different quantitative coronary arteriography (QCA) algorithms were compared. The three algorithms under comparison were a videodensitometric (V) algorithm, which does not require any geometric assumption for absolute vessel CSA measurement, and videodensitometric (VC) and edge detection (ED) algorithms, which do require the assumption of circular cross-section for CSA measurements. A cylindrical vessel phantom (0.5-4.75 mm in diameter) and a crescentic vessel phantom, producing 25% to 90% area stenosis, were imaged over the chest of a humanoid phantom. The low- and high-energy images were corrected for scatter and veiling glare before energy subtraction. For CSA measurements in crescentic vessel phantoms, the V algorithm produced significantly improved results (slope = 0.87, intercept = 0.51 mm2, r = .95) when compared to the VC (slope = 1.05, intercept = 4.19 mm2, r = .75) and the ED (slope = 1.57, intercept = 5.21 mm2, r = .60) algorithms.

Entities:  

Mesh:

Year:  1991        PMID: 2055711     DOI: 10.1097/00004424-199102000-00005

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  7 in total

1.  Validation of an accurate method for three-dimensional reconstruction and quantitative assessment of volumes, lengths and diameters of coronary vascular branches and segments from biplane angiographic projections.

Authors:  E Wellnhofer; A Wahle; I Mugaragu; J Gross; H Oswald; E Fleck
Journal:  Int J Card Imaging       Date:  1999-10

2.  Image correlation algorithm for measuring lymphocyte velocity and diameter changes in contracting microlymphatics.

Authors:  J Brandon Dixon; Anatoliy A Gashev; David C Zawieja; James E Moore; Gerard L Coté
Journal:  Ann Biomed Eng       Date:  2006-12-07       Impact factor: 3.934

3.  Absolute volumetric coronary blood flow measurement with digital subtraction angiography.

Authors:  S Molloi; G Bednarz; J Tang; Y Zhou; T Mathur
Journal:  Int J Card Imaging       Date:  1998-06

4.  In-vivo validation of videodensitometric coronary cross-sectional area measurement using dual-energy digital subtraction angiography.

Authors:  S Molloi; A Ersahin; J Hicks; J Wallis
Journal:  Int J Card Imaging       Date:  1995-12

5.  Calibration-free coronary artery measurements for interventional device sizing using inverse geometry x-ray fluoroscopy: in vivo validation.

Authors:  Michael T Tomkowiak; Amish N Raval; Michael S Van Lysel; Tobias Funk; Michael A Speidel
Journal:  J Med Imaging (Bellingham)       Date:  2014-10

6.  Assessment of vasoreactivity using videodensitometry coronary angiography.

Authors:  Sabee Molloi; Gholam R Berenji; Trien T Dang; Ghassan Kassab
Journal:  Int J Cardiovasc Imaging       Date:  2003-08       Impact factor: 2.357

7.  Effect of saline injection mixing on accuracy of conductance lumen sizing of peripheral vessels.

Authors:  Hyo Won Choi; Benjamin Jansen; David Birrer; Ghassan S Kassab
Journal:  PLoS One       Date:  2013-09-13       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.