Literature DB >> 1761507

An algorithm for angiographic estimation of blood vessel diameter.

A V Clough1, G S Krenz, M Owens, A al-Tinawi, C A Dawson, J H Linehan.   

Abstract

This study was carried out in an attempt to develop an objective and robust method for measuring changes in the diameters of small blood vessels from X-ray angiographic images. Recognizing potential problems with edge detection methods applied to cylindrical vessels in which the contrast diminishes as the boundary is approached, we have attempted to utilize the X-ray absorbance data across the entire cross section of the vessel. Then, assuming a cylindrical geometry, the absorbance data are fit to the cylindrical absorbance function by use of nonlinear regression analysis. The method was tested and calibrated using glass tubes filled with various concentrations of contrast medium. The diameters of small pulmonary arteries were estimated by applying the method of angiograms obtained from an isolated dog lung lobe. The structure of the residuals obtained after the fitting procedure was analyzed to test the appropriateness of the model for use with images of vessels. The results suggest that this approach will have utility for systematically quantifying vessel dimensions.

Entities:  

Mesh:

Year:  1991        PMID: 1761507     DOI: 10.1152/jappl.1991.71.5.2050

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  5 in total

1.  Image correlation algorithm for measuring lymphocyte velocity and diameter changes in contracting microlymphatics.

Authors:  J Brandon Dixon; Anatoliy A Gashev; David C Zawieja; James E Moore; Gerard L Coté
Journal:  Ann Biomed Eng       Date:  2006-12-07       Impact factor: 3.934

2.  Quantitative blood flow measurements in the small animal cardiopulmonary system using digital subtraction angiography.

Authors:  MingDe Lin; Craig T Marshall; Yi Qi; Samuel M Johnston; Cristian T Badea; Claude A Piantadosi; G Allan Johnson
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

3.  Regional transit time estimation from image residue curves.

Authors:  A V Clough; A al-Tinawi; J H Linehan; C A Dawson
Journal:  Ann Biomed Eng       Date:  1994 Mar-Apr       Impact factor: 3.934

4.  Mechanisms of airway responses to esophageal acidification in cats.

Authors:  Ivan M Lang; Steven T Haworth; Bidyut K Medda; Hubert Forster; Reza Shaker
Journal:  J Appl Physiol (1985)       Date:  2016-02-04

5.  Perfusion Angiography in Acute Ischemic Stroke.

Authors:  Fabien Scalzo; David S Liebeskind
Journal:  Comput Math Methods Med       Date:  2016-07-03       Impact factor: 2.238

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.