Literature DB >> 22734775

Sensitivity analysis of near-infrared functional lymphatic imaging.

Michael Weiler1, Timothy Kassis, J Brandon Dixon.   

Abstract

Near-infrared imaging of lymphatic drainage of injected indocyanine green (ICG) has emerged as a new technology for clinical imaging of lymphatic architecture and quantification of vessel function, yet the imaging capabilities of this approach have yet to be quantitatively characterized. We seek to quantify its capabilities as a diagnostic tool for lymphatic disease. Imaging is performed in a tissue phantom for sensitivity analysis and in hairless rats for in vivo testing. To demonstrate the efficacy of this imaging approach to quantifying immediate functional changes in lymphatics, we investigate the effects of a topically applied nitric oxide (NO) donor glyceryl trinitrate ointment. Premixing ICG with albumin induces greater fluorescence intensity, with the ideal concentration being 150 μg/mL ICG and 60 g/L albumin. ICG fluorescence can be detected at a concentration of 150 μg/mL as deep as 6 mm with our system, but spatial resolution deteriorates below 3 mm, skewing measurements of vessel geometry. NO treatment slows lymphatic transport, which is reflected in increased transport time, reduced packet frequency, reduced packet velocity, and reduced effective contraction length. NIR imaging may be an alternative to invasive procedures measuring lymphatic function in vivo in real time.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22734775      PMCID: PMC3381044          DOI: 10.1117/1.JBO.17.6.066019

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  45 in total

1.  Monte Carlo modeling for implantable fluorescent analyte sensors.

Authors:  M J McShane; S Rastegar; M Pishko; G L Coté
Journal:  IEEE Trans Biomed Eng       Date:  2000-05       Impact factor: 4.538

2.  Regional variations of contractile activity in isolated rat lymphatics.

Authors:  Anatoliy A Gashev; Michael J Davis; Michael D Delp; David C Zawieja
Journal:  Microcirculation       Date:  2004-09       Impact factor: 2.628

3.  Image correlation algorithm for measuring lymphocyte velocity and diameter changes in contracting microlymphatics.

Authors:  J Brandon Dixon; Anatoliy A Gashev; David C Zawieja; James E Moore; Gerard L Coté
Journal:  Ann Biomed Eng       Date:  2006-12-07       Impact factor: 3.934

Review 4.  Lymphatic endothelium in health and disease.

Authors:  Giorgia Jurisic; Michael Detmar
Journal:  Cell Tissue Res       Date:  2008-07-22       Impact factor: 5.249

5.  Determinants of valve gating in collecting lymphatic vessels from rat mesentery.

Authors:  Michael J Davis; Elaheh Rahbar; Anatoliy A Gashev; David C Zawieja; James E Moore
Journal:  Am J Physiol Heart Circ Physiol       Date:  2011-04-01       Impact factor: 4.733

Review 6.  Lymphedema.

Authors:  S G Rockson
Journal:  Am J Med       Date:  2001-03       Impact factor: 4.965

Review 7.  Lymphatic lipid transport: sewer or subway?

Authors:  J Brandon Dixon
Journal:  Trends Endocrinol Metab       Date:  2010-06-11       Impact factor: 12.015

8.  Inhibition of the active lymph pump by flow in rat mesenteric lymphatics and thoracic duct.

Authors:  Anatoliy A Gashev; Michael J Davis; David C Zawieja
Journal:  J Physiol       Date:  2002-05-01       Impact factor: 5.182

9.  Quantitative imaging of lymphatic function with liposomal indocyanine green.

Authors:  Steven T Proulx; Paola Luciani; Stefanie Derzsi; Matthias Rinderknecht; Viviane Mumprecht; Jean-Christophe Leroux; Michael Detmar
Journal:  Cancer Res       Date:  2010-09-07       Impact factor: 12.701

10.  Noninvasive quantitative imaging of lymph function in mice.

Authors:  Sunkuk Kwon; Eva M Sevick-Muraca
Journal:  Lymphat Res Biol       Date:  2007       Impact factor: 2.589

View more
  37 in total

1.  Augmented microscopy: real-time overlay of bright-field and near-infrared fluorescence images.

Authors:  Jeffrey R Watson; Christian F Gainer; Nikolay Martirosyan; Jesse Skoch; G Michael Lemole; Rein Anton; Marek Romanowski
Journal:  J Biomed Opt       Date:  2015-10       Impact factor: 3.170

2.  Effects of dynamic shear and transmural pressure on wall shear stress sensitivity in collecting lymphatic vessels.

Authors:  Jeffrey A Kornuta; Zhanna Nepiyushchikh; Olga Y Gasheva; Anish Mukherjee; David C Zawieja; J Brandon Dixon
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2015-09-02       Impact factor: 3.619

Review 3.  Imaging the lymphatic system.

Authors:  Lance L Munn; Timothy P Padera
Journal:  Microvasc Res       Date:  2014-06-21       Impact factor: 3.514

4.  Photoacoustic lymphatic imaging with high spatial-temporal resolution.

Authors:  Catherine Martel; Junjie Yao; Chih-Hsien Huang; Jun Zou; Gwendalyn J Randolph; Lihong V Wang
Journal:  J Biomed Opt       Date:  2014-11       Impact factor: 3.170

5.  The relationship between lymphangion chain length and maximum pressure generation established through in vivo imaging and computational modeling.

Authors:  Mohammad S Razavi; Tyler S Nelson; Zhanna Nepiyushchikh; Rudolph L Gleason; J Brandon Dixon
Journal:  Am J Physiol Heart Circ Physiol       Date:  2017-08-04       Impact factor: 4.733

6.  Minimally invasive method for the point-of-care quantification of lymphatic vessel function.

Authors:  Anna K Polomska; Steven T Proulx; Davide Brambilla; Daniel Fehr; Mathias Bonmarin; Simon Brändli; Mirko Meboldt; Christian Steuer; Tsvetina Vasileva; Nils Reinke; Jean-Christophe Leroux; Michael Detmar
Journal:  JCI Insight       Date:  2019-02-21

7.  Lymphatic function measurements influenced by contrast agent volume and body position.

Authors:  Echoe M Bouta; Cedric Blatter; Thomas A Ruggieri; Eelco Fj Meijer; Lance L Munn; Benjamin J Vakoc; Timothy P Padera
Journal:  JCI Insight       Date:  2018-01-25

8.  Minimally invasive method for determining the effective lymphatic pumping pressure in rats using near-infrared imaging.

Authors:  Tyler S Nelson; Ryan E Akin; Michael J Weiler; Timothy Kassis; Jeffrey A Kornuta; J Brandon Dixon
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2014-01-15       Impact factor: 3.619

9.  Dual-channel in-situ optical imaging system for quantifying lipid uptake and lymphatic pump function.

Authors:  Timothy Kassis; Alison B Kohan; Michael J Weiler; Matthew E Nipper; Rachel Cornelius; Patrick Tso; J Brandon Dixon
Journal:  J Biomed Opt       Date:  2012-08       Impact factor: 3.170

10.  Monitoring the primo vascular system in lymphatic vessels by using window chambers.

Authors:  Jungdae Kim; Dong-Hyun Kim; Sharon Jiyoon Jung; Hyun-Ji Gil; Seung Zhoo Yoon; Young-Il Kim; Kwang-Sup Soh
Journal:  Biomed Opt Express       Date:  2016-03-14       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.