Literature DB >> 19626412

Simultaneous imaging of magnetic resonance imaging and positron emission tomography by means of MRI-compatible optic fiber-based PET: a validation study in ex vivo rat brain.

Masao Imaizumi1, Seiichi Yamamoto, Makoto Kawakami, Masaaki Aoki, Eiji Sugiyama, Yasukazu Kanai, Eku Shimosegawa, Jun Hatazawa.   

Abstract

PURPOSE: We developed a new type of scintillation detector ring for positron emission tomography (PET). In this device the scintillation detectors were connected with 2.6 m length optic fibers to transport scintillation light to a photomultiplier (PMT) located apart from the detector rings. The present study aimed to test the possibility of simultaneous imaging with PET and magnetic resonance imaging (MRI) by means of the present PET device in ex vivo rat brain.
MATERIALS AND METHODS: The scintillation detector ring of 4 cm diameter was located in a magnetic field of 0.15 T open MRI. Simultaneous measurements of PET and MRI were performed in ex vivo rat brain after injection of (18)F-fluorodeoxyglucose ((18)F-FDG) 37 MBq and (18)F-NaF 37 MBq. Simultaneous data acquisition was performed for 10 min for PET and 5 min for T1-weighted MRI.
RESULTS: Simultaneous imaging of PET and MRI was possible without noticeable image distortion in the PET and MRI scans. In the fusion images, high uptake of (18)F-FDG was identified in the Harderian glands and striatum. High uptake of (18)F-NaF was found in the skull base and vault.
CONCLUSIONS: The present study indicated the possibility of simultaneous imaging of PET and MRI by means of optic fiber-based scintillation detectors.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19626412     DOI: 10.1007/s11604-009-0328-1

Source DB:  PubMed          Journal:  Jpn J Radiol        ISSN: 1867-1071            Impact factor:   2.374


  7 in total

1.  Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI.

Authors:  Bernd J Pichler; Martin S Judenhofer; Ciprian Catana; Jeffrey H Walton; Manfred Kneilling; Robert E Nutt; Stefan B Siegel; Claus D Claussen; Simon R Cherry
Journal:  J Nucl Med       Date:  2006-04       Impact factor: 10.057

2.  PET/MR images acquired with a compact MR-compatible PET detector in a 7-T magnet.

Authors:  Martin S Judenhofer; Ciprian Catana; Brian K Swann; Stefan B Siegel; Wulf-Ingo Jung; Robert E Nutt; Simon R Cherry; Claus D Claussen; Bernd J Pichler
Journal:  Radiology       Date:  2007-09       Impact factor: 11.105

Review 3.  Positron emission tomography/magnetic resonance imaging: the next generation of multimodality imaging?

Authors:  Bernd J Pichler; Hans F Wehrl; Armin Kolb; Martin S Judenhofer
Journal:  Semin Nucl Med       Date:  2008-05       Impact factor: 4.446

4.  Simultaneous MRI and PET imaging of a rat brain.

Authors:  Raymond R Raylman; Stan Majewski; Susan K Lemieux; S Sendhil Velan; Brian Kross; Vladimir Popov; Mark F Smith; Andrew G Weisenberger; Carl Zorn; Gary D Marano
Journal:  Phys Med Biol       Date:  2006-11-23       Impact factor: 3.609

5.  Simultaneous PET and MR imaging.

Authors:  Y Shao; S R Cherry; K Farahani; K Meadors; S Siegel; R W Silverman; P K Marsden
Journal:  Phys Med Biol       Date:  1997-10       Impact factor: 3.609

6.  A combined PET/CT scanner for clinical oncology.

Authors:  T Beyer; D W Townsend; T Brun; P E Kinahan; M Charron; R Roddy; J Jerin; J Young; L Byars; R Nutt
Journal:  J Nucl Med       Date:  2000-08       Impact factor: 10.057

7.  Simultaneous MR/PET imaging of the human brain: feasibility study.

Authors:  Heinz-Peter W Schlemmer; Bernd J Pichler; Matthias Schmand; Ziad Burbar; Christian Michel; Ralf Ladebeck; Kirstin Jattke; David Townsend; Claude Nahmias; Pradeep K Jacob; Wolf-Dieter Heiss; Claus D Claussen
Journal:  Radiology       Date:  2008-09       Impact factor: 11.105

  7 in total
  1 in total

1.  Diagnostic performance of fluorodeoxyglucose positron emission tomography/magnetic resonance imaging fusion images of gynecological malignant tumors: comparison with positron emission tomography/computed tomography.

Authors:  Kazuya Nakajo; Mitsuaki Tatsumi; Atsuo Inoue; Kayako Isohashi; Ichiro Higuchi; Hiroki Kato; Masao Imaizumi; Takayuki Enomoto; Eku Shimosegawa; Tadashi Kimura; Jun Hatazawa
Journal:  Jpn J Radiol       Date:  2010-02-26       Impact factor: 2.374

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.