Literature DB >> 17130798

Conservation of residual acoustic hearing after cochlear implantation.

Thomas J Balkany1, Sarah S Connell, Annelle V Hodges, Stacy L Payne, Fred F Telischi, Adrien A Eshraghi, Simon I Angeli, Ross Germani, Sarah Messiah, Kristopher L Arheart.   

Abstract

OBJECTIVE: This study was designed to test the hypothesis that partial hearing conservation is attainable after cochlear implantation with a long perimodiolar electrode. Surgical strategies for hearing conservation during cochlear implantation are described. STUDY
DESIGN: Prospective, single-subject, repeated-measures design.
SETTING: Academic tertiary care center. PATIENTS: Twenty-eight severely to profoundly hearing-impaired adult cochlear implant recipients who had some measurable hearing preoperatively. INTERVENTION: Cochlear implantation using Nucleus Freedom Contour Advance electrode. MAIN OUTCOME MEASURES: Preimplant and postimplant pure-tone thresholds and speech recognition scores were obtained to determine the incidence and degree of conserved hearing at a mean interval of 9 (+/-3.9) months.
RESULTS: Thirty-two percent of subjects experienced complete conservation of hearing (0- to 10-dB loss), and 57% experienced partial conservation of hearing (>11 dB) after implantation. However, open-set speech recognition was partially conserved in only one subject. Cochlear implant performance was not better in patients with conservation of residual hearing.
CONCLUSION: Conservation of pure-tone hearing was possible in 89% of implanted patients; however, residual speech perception was not conserved with this long perimodiolar electrode. A ceiling effect tends to inflate the prevalence of hearing conservation in implantation studies of severely to profoundly hearing-impaired patients.

Entities:  

Mesh:

Year:  2006        PMID: 17130798     DOI: 10.1097/01.mao.0000244355.34577.85

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


  44 in total

1.  Intra-Operative Neural Response Telemetry and Acoustic Reflex Assessment using an Advance-In-Stylet Technique and Modiolus-Hugging: A prospective cohort study.

Authors:  Abdulrahman Hagr
Journal:  Sultan Qaboos Univ Med J       Date:  2011-08-15

2.  Automated insertion of preformed cochlear implant electrodes: evaluation of curling behaviour and insertion forces on an artificial cochlear model.

Authors:  Thomas S Rau; Andreas Hussong; Martin Leinung; Thomas Lenarz; Omid Majdani
Journal:  Int J Comput Assist Radiol Surg       Date:  2009-04-10       Impact factor: 2.924

3.  Durability of Hearing Preservation after Cochlear Implantation with Conventional-Length Electrodes and Scala Tympani Insertion.

Authors:  Alex D Sweeney; Jacob B Hunter; Matthew L Carlson; Alejandro Rivas; Marc L Bennett; Rene H Gifford; Jack H Noble; David S Haynes; Robert F Labadie; George B Wanna
Journal:  Otolaryngol Head Neck Surg       Date:  2016-02-23       Impact factor: 3.497

4.  Residual hearing preservation using the suprameatal approach for cochlear implantation.

Authors:  Christoph Arnoldner; Wolfgang Gstoettner; Dominik Riss; Jens Wagenblast; Clemens Honeder; Michaela Blineder; Jafar-Sasan Hamzavi; Alexandra Jappel; Wolf-Dieter Baumgartner
Journal:  Wien Klin Wochenschr       Date:  2011-08-25       Impact factor: 1.704

5.  Deep round window insertion versus standard approach in cochlear implant surgery.

Authors:  Karl Fredrik Nordfalk; Kjell Rasmussen; Marie Bunne; Greg Eigner Jablonski
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-12-31       Impact factor: 2.503

6.  Verification of computed tomographic estimates of cochlear implant array position: a micro-CT and histologic analysis.

Authors:  Jessica Teymouri; Timothy E Hullar; Timothy A Holden; Richard A Chole
Journal:  Otol Neurotol       Date:  2011-08       Impact factor: 2.311

7.  Pattern of hearing loss following cochlear implantation.

Authors:  Eyal Raveh; Joseph Attias; Benny Nageris; Liora Kornreich; David Ulanovski
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-07-11       Impact factor: 2.503

8.  A Preliminary Investigation of the Air-Bone Gap: Changes in Intracochlear Sound Pressure With Air- and Bone-conducted Stimuli After Cochlear Implantation.

Authors:  Renee M Banakis Hartl; Jameson K Mattingly; Nathaniel T Greene; Herman A Jenkins; Stephen P Cass; Daniel J Tollin
Journal:  Otol Neurotol       Date:  2016-10       Impact factor: 2.311

9.  Intracochlear Pressure Transients During Cochlear Implant Electrode Insertion.

Authors:  Nathaniel T Greene; Jameson K Mattingly; Renee M Banakis Hartl; Daniel J Tollin; Stephen P Cass
Journal:  Otol Neurotol       Date:  2016-12       Impact factor: 2.311

Review 10.  The cochlear implant: historical aspects and future prospects.

Authors:  Adrien A Eshraghi; Ronen Nazarian; Fred F Telischi; Suhrud M Rajguru; Eric Truy; Chhavi Gupta
Journal:  Anat Rec (Hoboken)       Date:  2012-10-08       Impact factor: 2.064

View more