Comparison of a conventional and a flat-panel digital system in interventional cardiology procedures.

V Tsapaki1, S Kottou, N Kollaros, P Dafnomili, M Koutelou, E Vano, V Neofotistou.   

Abstract

The purpose of the study was to analyse the technical characteristics of a newly installed flat-panel fluoroscopy (FPF) system in an interventional cardiology (IC) department and compare it with an older conventional system. A patient survey was performed to investigate the radiation doses delivered by the X-ray systems. Finally, methods of technique optimization regarding the new digital system were investigated. Dose rates in all fluoroscopic and cine modes were measured and image quality assessed using a dedicated test tool. 200 patients were investigated, half using the conventional and half using the digital FPF system. Patient data collected were: sex, age, weight, height, dose-area product (DAP), fluoroscopy time (T) and total number of frames (F). Our results are: (1) Digital FPF system: high contrast resolution (HCR) is not affected by fluoroscopic mode, whereas low contrast resolution (LCR) is slightly decreased in the low mode. (2) The digital FPF system has 2.5 times better HCR than the conventional system, with 5 times lower dose in the fluoroscopy mode. (3) Median values of DAP, T and F, respectively, in coronary angiography (CA) are: 27.7 Gycm(2), 4.1 min and 876 for the digital and 39.3 Gycm(2), 5.3 min and 1600 for the conventional system. Median values for percutaneous transluminal coronary angioplasty (PTCA) are: 51.1 Gycm(2), 12.7 min and 1184 for the digital and 44.3 Gycm(2), 7.4 min and 1936 for the conventional system. Digital DAP in CA is reduced by 30%, suggesting that a dose reduction in the FPF system is possible. The results of the study concerning the FPF system lead to the conclusion that the lowest fluoroscopic mode and the lowest frame rate should be used in routine practice.

Entities:  

Mesh:

Year:  2004        PMID: 15238402     DOI: 10.1259/bjr/83257582

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  10 in total

1.  Comparison of image quality and radiation dose between an image-intensifier system and a newer-generation flat-panel detector system — technical phantom measurements and evaluation of clinical imaging in children.

Authors:  Meike Weis; Claudia Hagelstein; Theo Diehm; Stefan O Schoenberg; K Wolfgang Neff
Journal:  Pediatr Radiol       Date:  2016-02

2.  Do flat detector cardiac X-ray systems convey advantages over image-intensifier-based systems? Study comparing X-ray dose and image quality.

Authors:  Andrew G Davies; Arnold R Cowen; Stephen M Kengyelics; Janet Moore; Mohan U Sivananthan
Journal:  Eur Radiol       Date:  2006-11-18       Impact factor: 5.315

Review 3.  Minimising radiation exposure to physicians performing fluoroscopically guided cardiac catheterisation procedures: a review.

Authors:  Kwang Pyo Kim; Donald L Miller
Journal:  Radiat Prot Dosimetry       Date:  2009-03-27       Impact factor: 0.972

4.  Impact of biplane versus single-plane imaging on radiation dose, contrast load and procedural time in coronary angioplasty.

Authors:  V Sadick; W Reed; L Collins; N Sadick; R Heard; J Robinson
Journal:  Br J Radiol       Date:  2009-12-17       Impact factor: 3.039

5.  Reference levels for patient radiation doses in interventional radiology: proposed initial values for U.S. practice.

Authors:  Donald L Miller; Deukwoo Kwon; Grant H Bonavia
Journal:  Radiology       Date:  2009-09-29       Impact factor: 11.105

6.  Investigation of reference levels and radiation dose associated with abdominal EVAR (endovascular aneurysm repair) procedures across several European Centres.

Authors:  E Tuthill; L O'Hora; M O'Donohoe; S Panci; P Gilligan; D Campion; R Trenti; E Fox; D Catania; L Rainford
Journal:  Eur Radiol       Date:  2017-05-18       Impact factor: 5.315

7.  Radiation doses and estimated risk from angiographic projections during coronary angiography performed using novel flat detector.

Authors:  Anna Varghese; Roshan S Livingstone; Lijo Varghese; Parveen Kumar; Sirish Chandra Srinath; Oommen K George; Paul V George
Journal:  J Appl Clin Med Phys       Date:  2016-05-08       Impact factor: 2.102

8.  Patient radiation doses in interventional cardiology procedures.

Authors:  Ioannis Pantos; Georgios Patatoukas; Demosthenes G Katritsis; Efstathios Efstathopoulos
Journal:  Curr Cardiol Rev       Date:  2009-01

9.  Transition from image intensifier to flat panel detector in interventional cardiology: Impact of radiation dose.

Authors:  Roshan S Livingstone; David Chase; Anna Varghese; Paul V George; Oommen K George
Journal:  J Med Phys       Date:  2015 Jan-Mar

10.  Comparing ovarian radiation doses in flat-panel and conventional angiography during uterine artery embolization: a randomized clinical trial.

Authors:  Kavous Firouznia; Hossein Ghanaati; Aliakbar Sharafi; Firouze Abahashemi; Hassan Hashemi; Amir Hossein Jalali; Madjid Shakiba
Journal:  Iran J Radiol       Date:  2013-08-30       Impact factor: 0.212

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.