Literature DB >> 17094002

Efficacy of computer-assisted pedicle screw insertion for cervical instability in RA patients.

H Ito1, M Neo, M Yoshida, S Fujibayashi, H Yoshitomi, T Nakamura.   

Abstract

We evaluated the efficacy of the computer-assisted cervical pedicle screw insertion, compared with those inserted without the help of the system on the cervix of rheumatoid arthritis (RA) patients. Eighty-six cervical pedicle screws were inserted without the help of the system. Of the 86, 59 screws were in non-RA patients with degenerative spine, and 27 were in RA patients. The accuracy of the screw insertions was evaluated by a CT-based method. Then, 25 screws were inserted with the system into the cervical spines between C2 and C6 in RA patients (Navigation group). The efficacy of the system was assessed by the CT-based method, compared with 27 screws inserted without the system (Conventional group). The screws in RA patients tended to be more deviated than those in non-RA patients. In Conventional group, four screws (15%) were placed far laterally, and two (7%), far medially. In contrast, no screw was placed far laterally or medially in Navigation group (P < 0.05).

Entities:  

Mesh:

Year:  2006        PMID: 17094002     DOI: 10.1007/s00296-006-0256-7

Source DB:  PubMed          Journal:  Rheumatol Int        ISSN: 0172-8172            Impact factor:   2.631


  22 in total

1.  Prognosis of patients with upper cervical lesions caused by rheumatoid arthritis: comparison of occipitocervical fusion between c1 laminectomy and nonsurgical management.

Authors:  Shunji Matsunaga; Takashi Sakou; Toshiyuki Onishi; Kyoji Hayashi; Eiji Taketomi; Nobuhiko Sunahara; Setsuro Komiya
Journal:  Spine (Phila Pa 1976)       Date:  2003-07-15       Impact factor: 3.468

2.  Transpedicular screw placement evaluated by axial computed tomography of the cervical pedicle.

Authors:  Takeshi Sakamoto; Masashi Neo; Takashi Nakamura
Journal:  Spine (Phila Pa 1976)       Date:  2004-11-15       Impact factor: 3.468

3.  Relative contribution of cardiovascular risk factors and rheumatoid arthritis clinical manifestations to atherosclerosis.

Authors:  Inmaculada del Rincón; Gregory L Freeman; Roy W Haas; Daniel H O'Leary; Agustín Escalante
Journal:  Arthritis Rheum       Date:  2005-11

4.  Biomechanical analysis of cervical stabilization systems. An assessment of transpedicular screw fixation in the cervical spine.

Authors:  Y Kotani; B W Cunningham; K Abumi; P C McAfee
Journal:  Spine (Phila Pa 1976)       Date:  1994-11-15       Impact factor: 3.468

5.  A prospective study of the progression of rheumatoid arthritis of the cervical spine.

Authors:  P M Pellicci; C S Ranawat; P Tsairis; W J Bryan
Journal:  J Bone Joint Surg Am       Date:  1981-03       Impact factor: 5.284

6.  Pedicle screw fixation for nontraumatic lesions of the cervical spine.

Authors:  K Abumi; K Kaneda
Journal:  Spine (Phila Pa 1976)       Date:  1997-08-15       Impact factor: 3.468

7.  Biomechanical analysis of transpedicular screw fixation in the subaxial cervical spine.

Authors:  Ralph Kothe; Wolfgang Rüther; Erich Schneider; Berend Linke
Journal:  Spine (Phila Pa 1976)       Date:  2004-09-01       Impact factor: 3.468

8.  Incidence of noncardiac vascular disease in rheumatoid arthritis and relationship to extraarticular disease manifestations.

Authors:  Kimberly P Liang; Kelly V Liang; Eric L Matteson; Robyn L McClelland; Teresa J H Christianson; Carl Turesson
Journal:  Arthritis Rheum       Date:  2006-02

9.  Cervical spine fusion in rheumatoid arthritis.

Authors:  C S Ranawat; P O'Leary; P Pellicci; P Tsairis; P Marchisello; L Dorr
Journal:  J Bone Joint Surg Am       Date:  1979-10       Impact factor: 5.284

10.  Rheumatoid arthritis and vertebral artery occlusion: a case report with angiographic and magnetic resonance demonstration.

Authors:  M Loeb; A Bookman; D Mikulis
Journal:  J Rheumatol       Date:  1993-08       Impact factor: 4.666

View more
  25 in total

Review 1.  Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studies.

Authors:  Nai-Feng Tian; Qi-Shan Huang; Ping Zhou; Yang Zhou; Rui-Kai Wu; Yi Lou; Hua-Zi Xu
Journal:  Eur Spine J       Date:  2010-09-23       Impact factor: 3.134

2.  3D-based navigation in posterior stabilisations of the cervical and thoracic spine: problems and benefits. Results of 451 screws.

Authors:  J-S Jarvers; S Katscher; A Franck; S Glasmacher; C Schmidt; T Blattert; C Josten
Journal:  Eur J Trauma Emerg Surg       Date:  2011-04-01       Impact factor: 3.693

3.  Cervical anterior transpedicular screw fixation (ATPS)--Part II. Accuracy of manual insertion and pull-out strength of ATPS.

Authors:  Heiko Koller; Frank Acosta; Mark Tauber; Michael Fox; Hudelmaier Martin; Rosmarie Forstner; Peter Augat; Rainer Penzkofer; Christian Pirich; H Kässmann; Herbert Resch; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2008-01-26       Impact factor: 3.134

4.  Cervical anterior transpedicular screw fixation. Part I: Study on morphological feasibility, indications, and technical prerequisites.

Authors:  Heiko Koller; Axel Hempfing; Frank Acosta; Michael Fox; Armin Scheiter; Mark Tauber; Ulrich Holz; Herbert Resch; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2008-01-26       Impact factor: 3.134

5.  Image-guided pedicle screw insertion accuracy: a meta-analysis.

Authors:  Nai-Feng Tian; Hua-Zi Xu
Journal:  Int Orthop       Date:  2009-05-08       Impact factor: 3.075

Review 6.  Functional outcome of computer-assisted spinal pedicle screw placement: a systematic review and meta-analysis of 23 studies including 5,992 pedicle screws.

Authors:  Rajeev Verma; Sonal Krishan; Kurt Haendlmayer; A Mohsen
Journal:  Eur Spine J       Date:  2010-01-06       Impact factor: 3.134

7.  Clinical accuracy of cervical pedicle screw insertion using lateral fluoroscopy: a radiographic analysis of the learning curve.

Authors:  Hisashi Yoshimoto; Shigenobu Sato; Takahiko Hyakumachi; Yasushi Yanagibashi; Taiki Kanno; Takeshi Masuda
Journal:  Eur Spine J       Date:  2009-08-04       Impact factor: 3.134

Review 8.  Image-guided spine surgery: state of the art and future directions.

Authors:  Thorsten Tjardes; Sven Shafizadeh; Dieter Rixen; Thomas Paffrath; Bertil Bouillon; Eva S Steinhausen; Holger Baethis
Journal:  Eur Spine J       Date:  2009-09-11       Impact factor: 3.134

Review 9.  The evolution of image-guided lumbosacral spine surgery.

Authors:  Austin C Bourgeois; Austin R Faulkner; Alexander S Pasciak; Yong C Bradley
Journal:  Ann Transl Med       Date:  2015-04

10.  Perforation rates of cervical pedicle screw insertion by disease and vertebral level.

Authors:  Masashi Uehara; Jun Takahashi; Hiroki Hirabayashi; Hiroyuki Hashidate; Nobuhide Ogihara; Keijiro Mukaiyama; Shota Ikegami; Hiroyuki Kato
Journal:  Open Orthop J       Date:  2010-03-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.