Literature DB >> 17089827

Cone-beam mammo-computed tomography from data along two tilting arcs.

Kai Zeng1, Hengyong Yu, Laurie L Fajardo, Ge Wang.   

Abstract

Over the past several years there has been an increasing interest in cone-beam computed tomography (CT) for breast imaging. In this article, we propose a new scheme for theoretically exact cone-beam mammo-CT and develop a corresponding Katsevich-type reconstruction algorithm. In our scheme, cone-beam scans are performed along two tilting arcs to collect a sufficient amount of information for exact reconstruction. In our algorithm, cone-beam data are filtered in a shift-invariant fashion and then weighted backprojected into the three-dimensional space for the final reconstruction. Our approach has several desirable features, including tolerance of axial data truncation, efficiency in sequential/parallel implementation, and accuracy for quantitative analysis. We also demonstrate the system performance and clinical utility of the proposed technique in numerical simulations.

Mesh:

Year:  2006        PMID: 17089827     DOI: 10.1118/1.2336510

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Dedicated breast CT: radiation dose for circle-plus-line trajectory.

Authors:  Srinivasan Vedantham; Linxi Shi; Andrew Karellas; Frederic Noo
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

2.  Scatter radiation in digital tomosynthesis of the breast.

Authors:  Ioannis Sechopoulos; Sankararaman Suryanarayanan; Srinivasan Vedantham; Carl J D'Orsi; Andrew Karellas
Journal:  Med Phys       Date:  2007-02       Impact factor: 4.071

3.  Exact and approximate cone-beam reconstruction algorithms for C-arm based cone-beam CT using a two-concentric-arc source trajectory.

Authors:  Tingliang Zhuang; Joseph Zambelli; Brian Nett; Shuai Leng; Guang-Hong Chen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008

4.  An in vitro evaluation of cone-beam breast CT methods.

Authors:  Kai Zeng; Laurie L Fajardo; Simon Kao; Edmund A Franken; Jeong Mi Park; Zhenxue Jing; Er-Wei Bai; Ge Wang
Journal:  J Xray Sci Technol       Date:  2008-10-01       Impact factor: 1.535

Review 5.  Breast cancer imaging: a perspective for the next decade.

Authors:  Andrew Karellas; Srinivasan Vedantham
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

6.  Dedicated breast CT: geometric design considerations to maximize posterior breast coverage.

Authors:  Srinivasan Vedantham; Andrew Karellas; Margaret M Emmons; Lawrence J Moss; Sarwat Hussain; Stephen P Baker
Journal:  Phys Med Biol       Date:  2013-05-17       Impact factor: 3.609

Review 7.  Dedicated breast CT: state of the art-Part I. Historical evolution and technical aspects.

Authors:  Yueqiang Zhu; Avice M O'Connell; Yue Ma; Aidi Liu; Haijie Li; Yuwei Zhang; Xiaohua Zhang; Zhaoxiang Ye
Journal:  Eur Radiol       Date:  2021-08-03       Impact factor: 7.034

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.