Density conversion factor determined using a cone-beam computed tomography unit NewTom QR-DVT 9000.

M O Lagravère1, Y Fang, J Carey, R W Toogood, G V Packota, P W Major.   

Abstract

OBJECTIVE: The purpose of this study was to determine a conversion coefficient for Hounsfield Units (HU) to material density (g cm(-3)) obtained from cone-beam computed tomography (CBCT-NewTom QR-DVT 9000) data.
METHODS: Six cylindrical models of materials with different densities were made and scanned using the NewTom QR-DVT 9000 Volume Scanner. The raw data were converted into DICOM format and analysed using Merge eFilm and AMIRA to determine the HU of different areas of the models.
RESULTS: There was no significant difference (P = 0.846) between the HU given by each piece of software. A linear regression was performed using the density, rho (g cm(-3)), as the dependent variable in terms of the HU (H). The regression equation obtained was rho = 0.002H-0.381 with an R2 value of 0.986. The standard error of the estimation is 27.104 HU in the case of the Hounsfield Units and 0.064 g cm(-3) in the case of density.
CONCLUSION: CBCT provides an effective option for determination of material density expressed as Hounsfield Units.

Mesh:

Year:  2006        PMID: 17082330     DOI: 10.1259/dmfr/55276404

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  18 in total

1.  Deriving Hounsfield units using grey levels in cone beam CT: a clinical application.

Authors:  T E Reeves; P Mah; W D McDavid
Journal:  Dentomaxillofac Radiol       Date:  2012-06-29       Impact factor: 2.419

2.  Deriving Hounsfield units using grey levels in cone beam computed tomography.

Authors:  P Mah; T E Reeves; W D McDavid
Journal:  Dentomaxillofac Radiol       Date:  2010-09       Impact factor: 2.419

3.  Influence of graft quality and marginal bone loss on implants placed in maxillary grafted sinus: a finite element study.

Authors:  Samroeng Inglam; Siriwan Suebnukarn; Wichit Tharanon; Tratat Apatananon; Kriskrai Sitthiseripratip
Journal:  Med Biol Eng Comput       Date:  2010-04-29       Impact factor: 2.602

4.  Classification of periodontal biotypes with the use of CBCT. A cross-sectional study.

Authors:  Maria Nikiforidou; Lazaros Tsalikis; Christos Angelopoulos; Georgios Menexes; Ioannis Vouros; Antonios Konstantinides
Journal:  Clin Oral Investig       Date:  2015-12-22       Impact factor: 3.573

Review 5.  CBCT-based bone quality assessment: are Hounsfield units applicable?

Authors:  R Pauwels; R Jacobs; S R Singer; M Mupparapu
Journal:  Dentomaxillofac Radiol       Date:  2015       Impact factor: 2.419

Review 6.  Quality assurance phantoms for cone beam computed tomography: a systematic literature review.

Authors:  Marcus V L de Oliveira; Ann Wenzel; Paulo S F Campos; Rubens Spin-Neto
Journal:  Dentomaxillofac Radiol       Date:  2017-02-17       Impact factor: 2.419

7.  Influence of cone beam CT scanning parameters on grey value measurements at an implant site.

Authors:  A Parsa; N Ibrahim; B Hassan; A Motroni; P van der Stelt; D Wismeijer
Journal:  Dentomaxillofac Radiol       Date:  2012-08-29       Impact factor: 2.419

8.  Influence of exposure factors on the variability of CBCT voxel values: a phantom study.

Authors:  M L Oliveira; D Q Freitas; G M B Ambrosano; F Haiter-Neto
Journal:  Dentomaxillofac Radiol       Date:  2014-05-28       Impact factor: 2.419

9.  Can gray values derived from CT and cone beam CT estimate new bone formation? An in vivo study.

Authors:  Farshid Bastami; Shahriar Shahab; Azin Parsa; Fatemeh Mashhadi Abbas; Mohammad Hadi Noori Kooshki; Mahshid Namdari; Hamidreza Azimi Lisar; Tohid Rafiei; Farahnaz Fahimipour; Majid Salehi; Maissa Jafari
Journal:  Oral Maxillofac Surg       Date:  2017-10-31

10.  Combinatorial effects of lapatinib and rapamycin in triple-negative breast cancer cells.

Authors:  Tongrui Liu; Rami Yacoub; LaTonia D Taliaferro-Smith; Shi-Yong Sun; Tisheeka R Graham; Ryan Dolan; Christine Lobo; Mourad Tighiouart; Lily Yang; Amy Adams; Ruth M O'Regan
Journal:  Mol Cancer Ther       Date:  2011-06-20       Impact factor: 6.261

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.