Literature DB >> 17015598

Cementless total hip arthroplasty with the rectangular titanium Zweymuller stem. A concise follow-up, at a minimum of fifteen years, of a previous report.

Alexander Grübl1, Catharina Chiari, Alexander Giurea, Martin Gruber, Alexandra Kaider, Martina Marker, Harald Zehetgruber, Florian Gottsauner-Wolf.   

Abstract

Between October 1986 and November 1987, 208 total hip arthroplasties were performed with use of the cementless Zweymüller stem and a threaded cup in 200 consecutive patients. Of 102 patients (108 hips) who were available for follow-up at a minimum of 180 months postoperatively, eighty-three (eighty-nine hips) had the primary joint replacement still intact. No stem had been revised because of aseptic loosening, but we found various degrees of osteolysis around sixteen (18%) of the implants. The probability of survival of the stem at fifteen years was 0.98 (95% confidence interval, 0.96 to 1.00). The probability of survival of the cup was 0.85 (95% confidence interval, 0.79 to 0.91).

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17015598     DOI: 10.2106/JBJS.E.00810

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  21 in total

1.  Survival of the cementless Spotorno stem in the second decade.

Authors:  Peter R Aldinger; Alexander W Jung; Steffen J Breusch; Volker Ewerbeck; Dominik Parsch
Journal:  Clin Orthop Relat Res       Date:  2009-06-06       Impact factor: 4.176

2.  Long-term results of the Wagner conical screw cup.

Authors:  Alexander Schuh; Annemarie Schraml; Gerd Hohenberger
Journal:  Int Orthop       Date:  2008-06-26       Impact factor: 3.075

3.  Primary total hip arthroplasty with dual mobility socket to prevent dislocation: a 22-year follow-up of 240 hips.

Authors:  Bertrand Boyer; Rémi Philippot; Jean Geringer; Frédéric Farizon
Journal:  Int Orthop       Date:  2011-06-23       Impact factor: 3.075

4.  Total hip replacement in congenital high hip dislocation following iliofemoral monotube distraction.

Authors:  Johannes Holinka; Martin Pfeiffer; Jochen G Hofstaetter; Richard Lass; Rainer I Kotz; Alexander Giurea
Journal:  Int Orthop       Date:  2010-03-29       Impact factor: 3.075

5.  A cementless hip system with a new surface for osseous integration.

Authors:  Richard Lass; Alexander Kolb; Gobert Skrbensky; Georg Reinisch; Bernd Kubista; Alexander Giurea; Reinhard Windhager; Rainer Kotz
Journal:  Int Orthop       Date:  2013-10-11       Impact factor: 3.075

6.  Radiological identification of Zweymüller-type femoral stem prosthesis in revision cases.

Authors:  Saverio Affatato; Saverio Comitini; Matteo Fosco; Aldo Toni; Domenico Tigani
Journal:  Int Orthop       Date:  2016-02-29       Impact factor: 3.075

7.  Progressive femoral cortical and cancellous bone density loss after uncemented tapered-design stem fixation.

Authors:  Lutz A Mueller; Tobias E Nowak; Lothar Haeberle; Lars P Mueller; Alexander Kress; Michael Voelk; David Pfander; Raimund Forst; Rainer Schmidt
Journal:  Acta Orthop       Date:  2010-04       Impact factor: 3.717

8.  Long-term results of the threaded Mecron cup in primary total hip arthroplasty : A 15-20-year follow-up study.

Authors:  Michael Clarius; Alexander W Jung; Marcus R Streit; Christian Merle; Patric Raiss; Peter R Aldinger
Journal:  Int Orthop       Date:  2009-07-24       Impact factor: 3.075

9.  Long-term results of the threaded Weill cup in primary total hip arthroplasty: a 15-20-year follow-up study.

Authors:  Michael Clarius; Alexander W Jung; Patric Raiss; Marcus R Streit; Christian Merle; Peter R Aldinger
Journal:  Int Orthop       Date:  2009-07-24       Impact factor: 3.075

10.  Custom stems for femoral deformity in patients less than 40 years of age: 70 hips followed for an average of 14 years.

Authors:  Michael Akbar; Guenther Aldinger; Knut Krahmer; Thomas Bruckner; Peter R Aldinger
Journal:  Acta Orthop       Date:  2009-08       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.