Literature DB >> 26923378

Radiological identification of Zweymüller-type femoral stem prosthesis in revision cases.

Saverio Affatato1, Saverio Comitini2, Matteo Fosco3, Aldo Toni4,5, Domenico Tigani2.   

Abstract

INTRODUCTION: Since 1979 the number of patients treated with femoral stems has continued to grow, as well as the number of stems with features similar to the Zweymüller prosthesis produced by different companies. Identification can be problematic in case requiring revision. In the present paper, we present an overview of morphometric differences between the different stem designs, which can be useful for radiologic identification in revision cases.
METHODS: By doing some research on the Internet of specialized sites and worldwide literature, we searched for all femoral stems agreeing with Zweymüller principles (cementless, straight, tapered, rectangular cross-sectioned femoral stems).
RESULTS: We found 26 different stems from different companies producing or having produced in the past the Zweymüller-type femoral stems for hip prosthesis. DISCUSSION: Accurate preoperative identification of the Zweymüller femoral stem type may be of critical importance to eventual outcomes following revision surgery. Each manufacturer has different instruments specific to the removal of their primary implants, and ensuring they are available can simplify the revision procedure significantly. Exact pre-operative planning is also necessary for selecting the correct ball head in cases where a stem is well-fixed and can be left in situ. The commonly used notation "Eurocone 12/14" provides no information about the actual taper angle. Whenever the stem is left in situ, the exact specifications of the taper must therefore be obtained from the manufacturer in order to use a metal sleeve that precisely fits it and the ball head. Failure to do so may result in severe complications, such as metallosis. In cases where it is not possible to identify the taper angle, the surgeon may even consider removal of the stem, though this significantly increases the surgical procedure's invasiveness. Only a single, uniform standard taper, such as that offered until 1994 by CeramTec, can solve these issues in the future.
CONCLUSION: The survival rate of the Zweymüller stems after ten years was 96 % and the complication rate was very low. Pre-operative identification of the femoral implant is of considerable importance for planning and correctly implementing revision procedures.

Entities:  

Keywords:  Cementless; Hip designs; Radiologic identification; Taper angle compatibility; Total hip arthroplasty; Zweymüller hip prosthesis

Mesh:

Year:  2016        PMID: 26923378     DOI: 10.1007/s00264-016-3141-3

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  21 in total

1.  [Primary rotatory stability of hip endoprostheses stems after manual and robot assisted implantation].

Authors:  M Prymka; M Vogiatzis; J Hassenpflug
Journal:  Z Orthop Ihre Grenzgeb       Date:  2004 May-Jun

2.  Cementless total hip arthroplasty with the rectangular titanium Zweymuller stem. A concise follow-up, at a minimum of fifteen years, of a previous report.

Authors:  Alexander Grübl; Catharina Chiari; Alexander Giurea; Martin Gruber; Alexandra Kaider; Martina Marker; Harald Zehetgruber; Florian Gottsauner-Wolf
Journal:  J Bone Joint Surg Am       Date:  2006-10       Impact factor: 5.284

3.  Long-term results of a hydroxyapatite-coated femoral component in total hip replacement: a 15- to 21-year follow-up study.

Authors:  S S Rajaratnam; C Jack; A Tavakkolizadeh; M D George; R J Fletcher; M Hankins; J A N Shepperd
Journal:  J Bone Joint Surg Br       Date:  2008-01

4.  A cementless titanium hip endoprosthesis system based on press-fit fixation: basic research and clinical results.

Authors:  K Zweymüller
Journal:  Instr Course Lect       Date:  1986

5.  Concept and material properties of a cementless hip prosthesis system with Al2O3 ceramic ball heads and wrought Ti-6Al-4V stems.

Authors:  K Zweymüller; M Semlitsch
Journal:  Arch Orthop Trauma Surg       Date:  1982

6.  Ten to twelve-year results with the Zweymüller cementless total hip prosthesis.

Authors:  Ton M J S Vervest; Patricia G Anderson; Freek Van Hout; Frits-Hein Wapstra; Robert T Louwerse; Juriaan W A Koetsier
Journal:  J Arthroplasty       Date:  2005-04       Impact factor: 4.757

7.  Long-term results using the anatomic medullary locking hip prosthesis.

Authors:  C A Engh; A M Claus; R H Hopper; C A Engh
Journal:  Clin Orthop Relat Res       Date:  2001-12       Impact factor: 4.176

8.  Long-term results with the cementless Alloclassic brand hip arthroplasty system.

Authors:  Herwig Pieringer; Vinzenz Auersperg; Walter Griessler; Nikolaus Böhler
Journal:  J Arthroplasty       Date:  2003-04       Impact factor: 4.757

9.  The madreporic cementless total hip arthroplasty. New experimental data and a seven-year clinical follow-up study.

Authors:  G Lord; P Bancel
Journal:  Clin Orthop Relat Res       Date:  1983-06       Impact factor: 4.176

Review 10.  Performance of the CLS Spotorno uncemented stem in the third decade after implantation.

Authors:  F R Evola; G Evola; A Graceffa; A Sessa; V Pavone; L Costarella; G Sessa; S Avondo
Journal:  Bone Joint J       Date:  2014-04       Impact factor: 5.082

View more
  3 in total

1.  A new classification for proximal femur bone defects in conservative hip arthroplasty revisions.

Authors:  Filippo Casella; Fabio Favetti; Gabriele Panegrossi; Matteo Papalia; Francesco Falez
Journal:  Int Orthop       Date:  2018-12-11       Impact factor: 3.075

2.  Revision of ASR hip arthroplasty: analysis of two hundred and ninety six recalled patients at seven years.

Authors:  Giovanni Benelli; Merildo Maritato; Pierpaolo Cerulli Mariani; Francesco Sasso
Journal:  Int Orthop       Date:  2018-09-07       Impact factor: 3.075

3.  A new classification for proximal femur bone defects in conservative hip arthroplasty revisions.

Authors:  Filippo Casella; Fabio Favetti; Gabriele Panegrossi; Matteo Papalia; Francesco Falez
Journal:  Int Orthop       Date:  2018-11-15       Impact factor: 3.075

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.