Literature DB >> 17011461

Dosimetric comparison of four target alignment methods for prostate cancer radiotherapy.

Jennifer C O'Daniel1, Lei Dong, Lifei Zhang, Renaud de Crevoisier, He Wang, Andrew K Lee, Rex Cheung, Susan L Tucker, Rajat J Kudchadker, Mark D Bonnen, James D Cox, Radhe Mohan, Deborah A Kuban.   

Abstract

PURPOSE: The aim of this study was to compare the dosimetric consequences of 4 treatment delivery techniques for prostate cancer patients treated with intensity-modulated radiotherapy (IMRT). METHODS AND MATERIALS: During an 8-week course of radiotherapy, 10 patients underwent computed tomography (CT) scans 3 times per week (243 total) before daily treatment with a CT-linear accelerator. Treatment delivery was simulated by realigning a fixed-margin treatment plan on each CT scan and calculating doses. The alignment methods were those based on the following: skin marks, bony registration, ultrasonography (US), and in-room CT. For the last two methods, prostate was the alignment target. The dosimetric effects of these alignment methods on the prostate, seminal vesicles, rectum, and bladder were compared. The average daily minimum dose to 0.1 cm3 was used as the metric for target coverage.
RESULTS: Skin and bone alignments provided acceptable prostate coverage for only 70% of patients, US alignment for 90%, and CT alignment for 100%. CT-based alignment of the prostate provided seminal vesicle (SV) coverage of > or = 69 Gy for all patients; US and bone alignments provided SV coverage of > or = 60 Gy. This SV coverage may be acceptable for early-stage cancer (equivalent SV dose = 55.8 Gy at 1.8 Gy per fraction), but unacceptable for late-stage cancer (SV dose = 75.6 Gy). At 75.6 Gy, the acceptable rate for SV coverage was 40% for skin and bone alignments, 70% for US, and 80% for CT.
CONCLUSIONS: Direct target alignment methods (US and CT) provided better target coverage. CT-guided alignment provided the best and most consistent dosimetric coverage. A larger planning target volume margin is needed for SV coverage when the alignment target is the prostate.

Entities:  

Mesh:

Year:  2006        PMID: 17011461     DOI: 10.1016/j.ijrobp.2006.06.044

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  13 in total

1.  Comparison of a simple dose-guided intervention technique for prostate radiotherapy with existing anatomical image guidance methods.

Authors:  G Smyth; H M McCallum; M J M Pearson; G P Lawrence
Journal:  Br J Radiol       Date:  2011-03-08       Impact factor: 3.039

2.  Intensity modulated proton therapy treatment planning using single-field optimization: the impact of monitor unit constraints on plan quality.

Authors:  X R Zhu; N Sahoo; X Zhang; D Robertson; H Li; S Choi; A K Lee; M T Gillin
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

3.  Multi-system verification of registrations for image-guided radiotherapy in clinical trials.

Authors:  Yunfeng Cui; James M Galvin; William L Straube; Walter R Bosch; James A Purdy; X Allen Li; Ying Xiao
Journal:  Int J Radiat Oncol Biol Phys       Date:  2011-01-13       Impact factor: 7.038

4.  Reduction of prostate intrafractional motion from shortening the treatment time.

Authors:  Jin Sheng Li; Mu-Han Lin; Mark K Buyyounouski; Eric M Horwitz; Chang-Ming Ma
Journal:  Phys Med Biol       Date:  2013-06-25       Impact factor: 3.609

5.  Analysis of prostate patient setup and tracking data: potential intervention strategies.

Authors:  Zhong Su; Lisha Zhang; Martin Murphy; Jeffrey Williamson
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-10-08       Impact factor: 7.038

6.  Scanned ion beam therapy for prostate carcinoma: Comparison of single plan treatment and daily plan-adapted treatment.

Authors:  Sebastian Hild; Christian Graeff; Antoni Rucinski; Klemens Zink; Gregor Habl; Marco Durante; Klaus Herfarth; Christoph Bert
Journal:  Strahlenther Onkol       Date:  2015-11-27       Impact factor: 3.621

7.  Is a 3-mm intrafractional margin sufficient for daily image-guided intensity-modulated radiation therapy of prostate cancer?

Authors:  Adam D Melancon; Jennifer C O'Daniel; Lifei Zhang; Rajat J Kudchadker; Deborah A Kuban; Andrew K Lee; Rex M Cheung; Renaud de Crevoisier; Susan L Tucker; Wayne D Newhauser; Radhe Mohan; Lei Dong
Journal:  Radiother Oncol       Date:  2007-09-24       Impact factor: 6.280

8.  Dosimetric comparison of image guidance by megavoltage computed tomography versus bone alignment for prostate cancer radiotherapy.

Authors:  Jörn Kalz; Florian Sterzing; Kai Schubert; Gabriele Sroka-Perez; Jürgen Debus; Klaus Herfarth
Journal:  Strahlenther Onkol       Date:  2009-04-16       Impact factor: 3.621

9.  The role of seminal vesicle motion in target margin assessment for online image-guided radiotherapy for prostate cancer.

Authors:  Jian Liang; Qiuwen Wu; Di Yan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-12-26       Impact factor: 7.038

10.  Seminal vesicle interfraction displacement and margins in image guided radiotherapy for prostate cancer.

Authors:  Daisy Mak; Suki Gill; Roxby Paul; Alison Stillie; Annette Haworth; Tomas Kron; Jim Cramb; Kellie Knight; Jessica Thomas; Gillian Duchesne; Farshad Foroudi
Journal:  Radiat Oncol       Date:  2012-08-13       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.