Literature DB >> 23798642

Reduction of prostate intrafractional motion from shortening the treatment time.

Jin Sheng Li1, Mu-Han Lin, Mark K Buyyounouski, Eric M Horwitz, Chang-Ming Ma.   

Abstract

This study aims to quantify the reduction of the intrafractional motion when the prostate intensity modulated radiation therapy (IMRT) treatment time is shortened. Prostate intrafractional motion data recorded by the Calypso system for 105 patients was analyzed. Statistical distributions of the prostate displacements for the regular IMRT treatment and the first 1, 2, 3 and 5 min of the treatment were calculated and used for treatment margin estimation for all the selected patients. The treatment margins estimated for the first 1, 2, 3 and 5 min were compared with those for the regular IMRT treatment to quantify the reduction of the motion. If the treatment can be completed within 5 (3) min, the standard deviation of the prostate displacement could be reduced by up to 45% and the required treatment margins could be reduced to 1.2 (1.1), 0.9 (0.8), 2.2 (1.9), 1.9 (1.5), 1.9 (1.7) and 2.8 (2.4) mm from 1.5, 1.1, 2.8, 3.0, 2.4 and 3.9 mm in the left, right, superior, inferior, anterior and posterior directions, respectively. The same work was also performed for 19 of the 105 patients who exhibited the largest motion with 30% of their treatment time having 3D motion more than 3 mm. For this group of patients, the required margins change to 1.4 (1.2), 0.8 (0.8), 1.8 (1.6), 2.3 (1.8), 1.7 (1.5) and 3.4 (2.8) mm from 1.9, 1.2, 1.7, 3.7, 1.6 and 4.9 mm in the six directions when the treatment time is reduced to 5 (3) min. The intrafractional motion effects on prostate treatment are significantly smaller and the required margins can be therefore reduced when the treatment is shortened.

Entities:  

Mesh:

Year:  2013        PMID: 23798642      PMCID: PMC3940444          DOI: 10.1088/0031-9155/58/14/4921

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  36 in total

1.  The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy.

Authors:  M van Herk; P Remeijer; C Rasch; J V Lebesque
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-07-01       Impact factor: 7.038

2.  Cone-beam computed tomography with a flat-panel imager: initial performance characterization.

Authors:  D A Jaffray; J H Siewerdsen
Journal:  Med Phys       Date:  2000-06       Impact factor: 4.071

3.  Inclusion of geometric uncertainties in treatment plan evaluation.

Authors:  Marcel van Herk; Peter Remeijer; Joos V Lebesque
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-04-01       Impact factor: 7.038

Review 4.  Organ motion and its management.

Authors:  K M Langen; D T Jones
Journal:  Int J Radiat Oncol Biol Phys       Date:  2001-05-01       Impact factor: 7.038

5.  Evaluation of mechanical precision and alignment uncertainties for an integrated CT/LINAC system.

Authors:  Laurence Court; Isaac Rosen; Radhe Mohan; Lei Dong
Journal:  Med Phys       Date:  2003-06       Impact factor: 4.071

6.  Geometrical uncertainties, radiotherapy planning margins, and the ICRU-62 report.

Authors:  Joep C Stroom; Ben J M Heijmen
Journal:  Radiother Oncol       Date:  2002-07       Impact factor: 6.280

7.  Measurement of intrafractional prostate motion using magnetic resonance imaging.

Authors:  Dennis Mah; Gary Freedman; Bart Milestone; Alexandra Hanlon; Elizabeth Palacio; Theresa Richardson; Benjamin Movsas; Raj Mitra; Eric Horwitz; Gerald E Hanks
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-10-01       Impact factor: 7.038

8.  Daily prostate targeting using implanted radiopaque markers.

Authors:  Dale Litzenberg; Laura A Dawson; Howard Sandler; Martin G Sanda; Daniel L McShan; Randall K Ten Haken; Kwok L Lam; Kristy K Brock; James M Balter
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-03-01       Impact factor: 7.038

9.  Intrafraction prostate motion during IMRT for prostate cancer.

Authors:  Eugene Huang; Lei Dong; Anurag Chandra; Deborah A Kuban; Isaac I Rosen; Anissa Evans; Alan Pollack
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-06-01       Impact factor: 7.038

10.  Evaluation of CyberKnife frameless real-time image-guided stereotactic radiosurgery for spinal lesions.

Authors:  Peter C Gerszten; Cihat Ozhasoglu; Steven A Burton; William Vogel; Barbara Atkins; Shalom Kalnicki; William C Welch
Journal:  Stereotact Funct Neurosurg       Date:  2003       Impact factor: 1.875

View more
  8 in total

1.  Dosimetric implications of inter- and intrafractional prostate positioning errors during tomotherapy : Comparison of gold marker-based registrations with native MVCT.

Authors:  Peter Wust; Marc Joswig; Reinhold Graf; Dirk Böhmer; Marcus Beck; Thomasz Barelkowski; Volker Budach; Pirus Ghadjar
Journal:  Strahlenther Onkol       Date:  2017-05-02       Impact factor: 3.621

2.  Intrafractional prostate motion during external beam radiotherapy monitored by a real-time target localization system.

Authors:  Xu Tong; Xiaoming Chen; Jinsheng Li; Qianqian Xu; Mu-Han Lin; Lili Chen; Robert A Price; Chang-Ming Ma
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

3.  Intrafraction Prostate Motion Management During Dose-Escalated Linac-Based Stereotactic Body Radiation Therapy.

Authors:  Denis Panizza; Valeria Faccenda; Raffaella Lucchini; Martina Camilla Daniotti; Sara Trivellato; Paolo Caricato; Valerio Pisoni; Elena De Ponti; Stefano Arcangeli
Journal:  Front Oncol       Date:  2022-04-07       Impact factor: 5.738

4.  Intrafraction Prostate Motion Management for Ultra-Hypofractionated Radiotherapy of Prostate Cancer.

Authors:  Christoph Oehler; Nina Roehner; Marcin Sumila; Jürgen Curschmann; Fabrizio Storelli; Daniel Rudolf Zwahlen; Uwe Schneider
Journal:  Curr Oncol       Date:  2022-08-31       Impact factor: 3.109

5.  Whole-pelvic volumetric-modulated arc therapy for high-risk prostate cancer: treatment planning and acute toxicity.

Authors:  Kentaro Ishii; Ryo Ogino; Yukinari Hosokawa; Chiaki Fujioka; Wataru Okada; Ryota Nakahara; Ryu Kawamorita; Takuhito Tada; Yoshiki Hayashi; Toshifumi Nakajima
Journal:  J Radiat Res       Date:  2014-10-10       Impact factor: 2.724

6.  Determining intrafractional prostate motion using four dimensional ultrasound system.

Authors:  Mariwan Baker; Claus F Behrens
Journal:  BMC Cancer       Date:  2016-07-15       Impact factor: 4.430

7.  Correlation between intrafractional motion and dosimetric changes for prostate IMRT: Comparison of different adaptive strategies.

Authors:  Nami Saito; Daniela Schmitt; Mark Bangert
Journal:  J Appl Clin Med Phys       Date:  2018-06-03       Impact factor: 2.102

8.  Early clinical experience with varian halcyon V2 linear accelerator: Dual-isocenter IMRT planning and delivery with portal dosimetry for gynecological cancer treatments.

Authors:  Hayeon Kim; M Saiful Huq; Ron Lalonde; Christopher J Houser; Sushil Beriwal; Dwight E Heron
Journal:  J Appl Clin Med Phys       Date:  2019-10-29       Impact factor: 2.102

  8 in total