BACKGROUND AND PURPOSE: Daily image guidance in irradiation of prostate cancer can be based on simple portal images or on soft-tissue imaging. This study compares daily bone alignment with daily pretreatment megavoltage computed tomography (MVCT). PATIENTS AND METHODS: Ten patients with a total of 356 fractions were analyzed. Before each fraction, the patient was positioned to match the prostate on pretreatment MVCT and planning CT. In seven fractions, rectum distension prevented a satisfactory match and the fraction was restarted after the patient went to the restroom. After treatment, organs were manually contoured on each daily MVCT and doses recalculated. Bone alignment was simulated by a software that matches the bones on MVCT and planning CT. RESULTS: In the seven interrupted fractions, median improvement of rectum volume receiving full fraction dose was 14 cm(3) between simulated treatment before and actual treatment after the patient went to the restroom. In the 349 noninterrupted fractions, the average difference of the isodose that covers 95% of the prostate between actual treatment position and simulated bone match position was < 1% and there was no significant change in the rectum volume with a fraction dose > or = 2 Gy. CONCLUSION: Full fraction dose rectum irradiation can be avoided with daily MVCT by interruption of single fractions. There was no relevant benefit of daily MVCT in the noninterrupted fractions with the margins used in this study.
BACKGROUND AND PURPOSE: Daily image guidance in irradiation of prostate cancer can be based on simple portal images or on soft-tissue imaging. This study compares daily bone alignment with daily pretreatment megavoltage computed tomography (MVCT). PATIENTS AND METHODS: Ten patients with a total of 356 fractions were analyzed. Before each fraction, the patient was positioned to match the prostate on pretreatment MVCT and planning CT. In seven fractions, rectum distension prevented a satisfactory match and the fraction was restarted after the patient went to the restroom. After treatment, organs were manually contoured on each daily MVCT and doses recalculated. Bone alignment was simulated by a software that matches the bones on MVCT and planning CT. RESULTS: In the seven interrupted fractions, median improvement of rectum volume receiving full fraction dose was 14 cm(3) between simulated treatment before and actual treatment after the patient went to the restroom. In the 349 noninterrupted fractions, the average difference of the isodose that covers 95% of the prostate between actual treatment position and simulated bone match position was < 1% and there was no significant change in the rectum volume with a fraction dose > or = 2 Gy. CONCLUSION: Full fraction dose rectum irradiation can be avoided with daily MVCT by interruption of single fractions. There was no relevant benefit of daily MVCT in the noninterrupted fractions with the margins used in this study.
Authors: Xavier Artignan; Monique H P Smitsmans; Jos V Lebesque; David A Jaffray; Marcel van Her; Harry Bartelink Journal: Int J Radiat Oncol Biol Phys Date: 2004-06-01 Impact factor: 7.038
Authors: Sanford L Meeks; Joseph F Harmon; Katja M Langen; Twyla R Willoughby; Thomas H Wagner; Patrick A Kupelian Journal: Med Phys Date: 2005-08 Impact factor: 4.071
Authors: Jennifer C O'Daniel; Lei Dong; Lifei Zhang; Renaud de Crevoisier; He Wang; Andrew K Lee; Rex Cheung; Susan L Tucker; Rajat J Kudchadker; Mark D Bonnen; James D Cox; Radhe Mohan; Deborah A Kuban Journal: Int J Radiat Oncol Biol Phys Date: 2006-11-01 Impact factor: 7.038
Authors: J Lattanzi; S McNeeley; W Pinover; E Horwitz; I Das; T E Schultheiss; G E Hanks Journal: Int J Radiat Oncol Biol Phys Date: 1999-03-01 Impact factor: 7.038
Authors: J Wu; T Haycocks; H Alasti; G Ottewell; N Middlemiss; M Abdolell; P Warde; A Toi; C Catton Journal: Radiother Oncol Date: 2001-11 Impact factor: 6.280
Authors: Eugene Huang; Lei Dong; Anurag Chandra; Deborah A Kuban; Isaac I Rosen; Anissa Evans; Alan Pollack Journal: Int J Radiat Oncol Biol Phys Date: 2002-06-01 Impact factor: 7.038
Authors: Ronaldo Cavalieri; Hiram A Gay; Jingxia Liu; Maria C Ferreira; Helvecio C Mota; Claudio H Sibata; Ron R Allison Journal: Radiat Oncol Date: 2011-10-24 Impact factor: 3.481