Literature DB >> 17001708

Biomechanical evaluation of a new augmentation method for enhanced screw fixation in osteoporotic proximal femoral fractures.

P von der Linden1, A Gisep, V Boner, M Windolf, A Appelt, N Suhm.   

Abstract

A biomechanical investigation on eight pairs of human cadaver proximal femurs was performed to evaluate the impact of a new augmentation method on the internal fixation of osteoporotic proximal femur fractures. The study focused on enhancing implant purchase to reduce the incidence of implant cut-out in osteoporotic bone. In a left-right comparison, a conventional hip screw fixation (control) was compared to the new cement augmentation method. After bone bed preparation through high pressure irrigation to remove fat, blood, and bone debris, the bones were augmented with low viscosity polymethylmethacrylate (PMMA) cement. Step-wise fatigue testing was performed by cyclically loading the femoral heads in a physiological manner, beginning at 1,500 N and increasing 500 N every 5,000 cycles to 4,000 N, and continuously monitoring head displacement. Failure was defined as >5.0 mm head displacement. The head displacement at 2,000 N was significantly smaller (p=0.018) for the augmented group as compared to the conventionally treated bones (0.09+/-0.01 mm vs. 0.90+/-0.32 mm; mean+/-SEM). The displacement rate at the second load step was significantly higher (p=0.018) for the conventionally treated bones as compared to the augmented ones. All of the nonaugmented specimens failed during testing, where 50% of the augmented specimens did not fail. The promising results of these experiments suggest that this new standardized irrigation/augmentation method enhances the implant anchorage and offers a potential solution to the problem of implant cut-out in osteoporotic metaphyseal bone. Copyright (c) 2006 Orthopaedic Research Society.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17001708     DOI: 10.1002/jor.20299

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  14 in total

1.  Cement augmentation of the proximal femur nail antirotation: is it safe?

Authors:  Konrad Schuetze; S Ehinger; A Eickhoff; C Dehner; F Gebhard; P H Richter
Journal:  Arch Orthop Trauma Surg       Date:  2020-07-25       Impact factor: 3.067

Review 2.  [Biomechanics of implant augmentation].

Authors:  M Windolf
Journal:  Unfallchirurg       Date:  2015-09       Impact factor: 1.000

3.  Influence of fragment volume on stability of 3-part intertrochanteric fracture of the femur: a biomechanical study.

Authors:  Jung-Hoon Do; Yong-Sik Kim; Sung-Jae Lee; Myoung-Lae Jo; Suk-Ku Han
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-04-04

4.  Enhancement of holding strength of cannulated screw supported with PMMA: a biomechanical study on femoral head [corrected].

Authors:  Reşad Zeynalov; İsmail Ağır; Ahmet Hamdi Akgülle; Barış Kocaoğlu; Mithat Selim Yalçın
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-09-12

Review 5.  [Treatment of peritrochanteric fractures: biomechanical considerations].

Authors:  G Krischak; L Dürselen; G Röderer
Journal:  Unfallchirurg       Date:  2011-06       Impact factor: 1.000

6.  Failure after osteosynthesis of trochanteric fractures. Where is the limit of osteoporosis?

Authors:  L Konstantinidis; C Papaioannou; P Blanke; A Hirschmüller; N P Südkamp; P Helwig
Journal:  Osteoporos Int       Date:  2013-05-24       Impact factor: 4.507

Review 7.  Acrylic bone cement: current concept review.

Authors:  B Magnan; M Bondi; T Maluta; E Samaila; L Schirru; C Dall'Oca
Journal:  Musculoskelet Surg       Date:  2013-07-27

Review 8.  [Augmentation techniques on the proximal femur].

Authors:  C Neuerburg; M Gosch; M Blauth; W Böcker; C Kammerlander
Journal:  Unfallchirurg       Date:  2015-09       Impact factor: 1.000

9.  Selective local delivery of RANK siRNA to bone phagocytes using bone augmentation biomaterials.

Authors:  Yuwei Wang; Kenny K Tran; Hong Shen; David W Grainger
Journal:  Biomaterials       Date:  2012-09-03       Impact factor: 12.479

Review 10.  Cement augmentation for trochanteric fracture in elderly: A systematic review.

Authors:  Leonardo Stramazzo; Salvatore Ratano; Francesco Monachino; Davide Pavan; Giuseppe Rovere; Lawrence Camarda
Journal:  J Clin Orthop Trauma       Date:  2020-10-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.