Literature DB >> 17001442

Strength of tissue attachment to mesh after ventral hernia repair with synthetic composite mesh in a porcine model.

S Majercik1, V Tsikitis, D A Iannitti.   

Abstract

BACKGROUND: A prospective animal study involving 12 female swine aimed to measure the strength of tissue attachment to composite mesh at various time points after laparoscopic ventral hernia repair in a porcine model.
METHODS: Each animal had two 10 x 16-cm sheets of polypropylene/expanded polytetrafluoroethylene (ePTFE) composite mesh laparoscopically affixed to the abdominal wall with a helical tacking device. No transfascial sutures were used. The animals were euthanized 2, 4, 6, and 12 weeks after surgery, and abdominal walls were resected en bloc with the patches. Each patch was cut into 2 x 7-cm strips, and each strip was independently analyzed. The strength of the tissue attachment to the mesh was measured using a servohydraulic tensile testing frame. The abdominal wall was peeled from the mesh, and the transverse, or "lap-shear" force was recorded. Data are reported as mean force in pounds.
RESULTS: The mean lap-shear force was 0.83 +/- 0.06 lbs at 2 weeks, 1.06 +/- 0.07 lbs at 4 weeks, 0.88 +/- 0.08 lbs at 6 weeks, and 1.13 +/- 0.07 lbs at 12 weeks. The mean force was higher at 12 weeks than at 2 weeks (p < 0.05). No other periods were significantly different from any other.
CONCLUSIONS: The findings demonstrate that the majority of tissue ingrowth and strength has occurred by 2 weeks after laparoscopic placement of a composite hernia prosthesis. Strength very gradually increases until 12 weeks after surgery. This has clinical implications for human ventral hernia repair. Further study is needed to evaluate the necessity of transfascial sutures for securing polypropylene-based prostheses to the abdominal wall during ventral hernia repair.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17001442     DOI: 10.1007/s00464-005-0660-1

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  20 in total

1.  Long-term complications associated with prosthetic repair of incisional hernias.

Authors:  G E Leber; J L Garb; A I Alexander; W P Reed
Journal:  Arch Surg       Date:  1998-04

2.  Long-term results after surgical correction of incisional hernia.

Authors:  F T van der Linden; T J van Vroonhoven
Journal:  Neth J Surg       Date:  1988-10

3.  Laparoscopic repair of incisional abdominal hernias using expanded polytetrafluoroethylene: preliminary findings.

Authors:  K A LeBlanc; W V Booth
Journal:  Surg Laparosc Endosc       Date:  1993-02

4.  Retrorectus prosthetic mesh repair of midline abdominal hernia.

Authors:  D McLanahan; L T King; C Weems; M Novotney; K Gibson
Journal:  Am J Surg       Date:  1997-05       Impact factor: 2.565

5.  Comparison of laparoscopic and open ventral herniorrhaphy.

Authors:  B J Ramshaw; P Esartia; J Schwab; E M Mason; R A Wilson; T D Duncan; J Miller; G W Lucas; J Promes
Journal:  Am Surg       Date:  1999-09       Impact factor: 0.688

6.  Factors affecting wound complications in repair of ventral hernias.

Authors:  T J White; M C Santos; J S Thompson
Journal:  Am Surg       Date:  1998-03       Impact factor: 0.688

7.  Laparoscopic treatment vs open surgery in the solution of major incisional and abdominal wall hernias with mesh.

Authors:  M A Carbajo; J C Martín del Olmo; J I Blanco; C de la Cuesta; M Toledano; F Martin; C Vaquero; L Inglada
Journal:  Surg Endosc       Date:  1999-03       Impact factor: 4.584

8.  Laparoscopic repair of ventral hernias: nine years' experience with 850 consecutive hernias.

Authors:  B Todd Heniford; Adrian Park; Bruce J Ramshaw; Guy Voeller
Journal:  Ann Surg       Date:  2003-09       Impact factor: 12.969

9.  Prevention of adhesion formation to polypropylene mesh by collagen coating: a randomized controlled study in a rat model of ventral hernia repair.

Authors:  M van't Riet; J W A Burger; F Bonthuis; J Jeekel; H J Bonjer
Journal:  Surg Endosc       Date:  2004-03-19       Impact factor: 4.584

10.  The internal retention repair of massive ventral hernia.

Authors:  J V Sitzmann; D W McFadden
Journal:  Am Surg       Date:  1989-12       Impact factor: 0.688

View more
  15 in total

1.  Histologic and biomechanical evaluation of a novel macroporous polytetrafluoroethylene knit mesh compared to lightweight and heavyweight polypropylene mesh in a porcine model of ventral incisional hernia repair.

Authors:  L Melman; E D Jenkins; N A Hamilton; L C Bender; M D Brodt; C R Deeken; S C Greco; M M Frisella; B D Matthews
Journal:  Hernia       Date:  2011-01-30       Impact factor: 4.739

2.  Anisotropic evaluation of synthetic surgical meshes.

Authors:  E R Saberski; S B Orenstein; Y W Novitsky
Journal:  Hernia       Date:  2010-09-30       Impact factor: 4.739

3.  Mesh implants: An overview of crucial mesh parameters.

Authors:  Lei-Ming Zhu; Philipp Schuster; Uwe Klinge
Journal:  World J Gastrointest Surg       Date:  2015-10-27

4.  A pilot study comparing anatomic failure after sacrocolpopexy with absorbable or permanent sutures for vaginal mesh attachment.

Authors:  Jasmine Tan-Kim; Shawn A Menefee; Quinn Lippmann; Emily S Lukacz; Karl M Luber; Charles W Nager
Journal:  Perm J       Date:  2014

5.  One and four layer acellular bladder matrix for fascial tissue reconstruction.

Authors:  Daniel Eberli; Anthony Atala; James J Yoo
Journal:  J Mater Sci Mater Med       Date:  2011-02-01       Impact factor: 3.896

6.  Laparoscopic mechanical fixation devices: does firing angle matter?

Authors:  Emmanuel E Sadava; David M Krpata; Yue Gao; Steve Schomisch; Michael J Rosen; Yuri W Novitsky
Journal:  Surg Endosc       Date:  2013-01-09       Impact factor: 4.584

7.  Multicentric observational cohort study evaluating a composite mesh with incorporated oxidized regenerated cellulose in laparoscopic ventral hernia repair.

Authors:  F Berrevoet; K Fierens; J De Gols; B Navez; W Van Bastelaere; E Meir; R Ceulemans
Journal:  Hernia       Date:  2008-08-06       Impact factor: 4.739

8.  Laparoscopic intraperitoneal mesh fixation with fibrin sealant (Tisseel) vs. titanium tacks: a randomised controlled experimental study in pigs.

Authors:  J R Eriksen; J I Bech; D Linnemann; J Rosenberg
Journal:  Hernia       Date:  2008-05-16       Impact factor: 4.739

Review 9.  Choice of mesh for laparoscopic ventral hernia repair.

Authors:  J R Eriksen; I Gögenur; J Rosenberg
Journal:  Hernia       Date:  2007-09-11       Impact factor: 4.739

10.  Strength of tissue attachment to composite and ePTFE grafts after ventral hernia repair.

Authors:  David A Iannitti; William W Hope; Vassiliki Tsikitis
Journal:  JSLS       Date:  2007 Oct-Dec       Impact factor: 2.172

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.