An investigation of operator exposure in interventional radiology.

Beth A Schueler1, Thomas J Vrieze, Haraldur Bjarnason, Anthony W Stanson.   

Abstract

A study was conducted to investigate how operator exposure in interventional radiology is affected by various common fluoroscopic imaging conditions. Stray radiation levels surrounding the imaging chain of a C-arm angiographic system were measured with an anthropomorphic abdomen phantom under different imaging conditions, and isodose curves were constructed. Operator exposure was shown to increase with patient dose-area product as the imaging field of view (FOV) is changed, with the highest scatter levels occurring with an intermediate-sized FOV. Use of copper spectral beam filtration was found to result in decreased operator exposure, whereas use of wedge-shaped equalization filters was found to increase exposure. The effect of increasing patient abdomen thickness was simulated by surrounding the phantom with plastic bolus material. Increasing the thickness by 5 cm resulted in a doubling of exposure at the operator's waist. Exposure to the operator's upper body was significantly reduced when the FOV was positioned on the far side of the patient. Operator exposure can be maintained at an acceptable level by taking these variables into consideration and incorporating the suggested dose reduction techniques into routine practice to the greatest extent possible. Copyright RSNA, 2006.

Entities:  

Mesh:

Year:  2006        PMID: 16973780     DOI: 10.1148/rg.265055127

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  17 in total

Review 1.  Occupational radiation doses to operators performing fluoroscopically-guided procedures.

Authors:  Kwang Pyo Kim; Donald L Miller; Amy Berrington de Gonzalez; Stephen Balter; Ruth A Kleinerman; Evgenia Ostroumova; Steven L Simon; Martha S Linet
Journal:  Health Phys       Date:  2012-07       Impact factor: 1.316

2.  Reduction of radiation exposure by lead curtain shielding in dedicated extremity cone beam CT.

Authors:  C-H Lee; J H Ryu; Y-H Lee; K-H Yoon
Journal:  Br J Radiol       Date:  2015-03-26       Impact factor: 3.039

3.  An investigation of the radiation doses to the lower legs and feet of staff undertaking interventional procedures.

Authors:  R E R Artschan; D S Brettle; K Chase; A Fender; P G Howells; S Buchan
Journal:  Br J Radiol       Date:  2014-03-06       Impact factor: 3.039

4.  Totally Implantable Central Venous Port Catheters: Radiation Exposure as a Function of Puncture Site and Operator Experience.

Authors:  Martin Jonczyk; Bernhard Gebauer; Roman Rotzinger; Dirk Schnapauff; Bernd Hamm; Federico Collettini
Journal:  In Vivo       Date:  2018 Jan-Feb       Impact factor: 2.155

5.  Occupational radiation protection in interventional radiology: a joint guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional Radiology.

Authors:  Donald L Miller; Eliseo Vañó; Gabriel Bartal; Stephen Balter; Robert Dixon; Renato Padovani; Beth Schueler; John F Cardella; Thierry de Baère
Journal:  Cardiovasc Intervent Radiol       Date:  2009-12-18       Impact factor: 2.740

6.  Efficacy of a radiation safety education initiative in reducing radiation exposure in the pediatric IR suite.

Authors:  David D Sheyn; John M Racadio; Jun Ying; Manish N Patel; Judy M Racadio; Neil D Johnson
Journal:  Pediatr Radiol       Date:  2008-04-15

7.  Evaluation of Radiation Exposure on Physicians During Angioplasty for Hemodialysis Access Dysfunction.

Authors:  Po-Sen Huang; Zhih-Cherng Chen; Kuo-Ting Tang; Wei-Ting Chang
Journal:  Acta Cardiol Sin       Date:  2019-01       Impact factor: 2.672

8.  High filtration in interventional practices reduces patient radiation doses but not always scatter radiation doses.

Authors:  Roberto M Sanchez; Eliseo Vano; Pablo Salinas; Nieves Gonzalo; Javier Escaned; Jose M Fernández
Journal:  Br J Radiol       Date:  2020-11-24       Impact factor: 3.039

9.  Is It Safe to Use a Lead Screen During Hip Arthroscopy?

Authors:  Alexander Rahill; Leah Biffin; Camdon Fary; Alasdair G Sutherland; Phong Tran
Journal:  Arthrosc Sports Med Rehabil       Date:  2021-02-03

10.  Impact of the Ceiling-Mounted Radiation Shielding Position on the Physician's Dose from Scatter Radiation during Interventional Procedures.

Authors:  Lucie Sukupova; Ondrej Hlavacek; Daniel Vedlich
Journal:  Radiol Res Pract       Date:  2018-01-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.