Literature DB >> 16971627

Radiation exposure of patients in comprehensive computed tomography of the head in acute stroke.

M Cohnen1, H-J Wittsack, S Assadi, K Muskalla, A Ringelstein, L W Poll, A Saleh, U Mödder.   

Abstract

BACKGROUND AND
PURPOSE: To assess patient radiation exposure in comprehensive stroke imaging using multidetector row CT (MDCT) combining standard CT of the head, cerebral perfusion (CTP), and CT angiography (CTA) studies.
METHODS: Examination protocols for CT and CTA of cerebral and cervical vessels, as well as CTP were simulated using a Somatom Sensation Cardiac 64. Effective doses were derived from measurements with the use of lithium-fluoride thermoluminescent dosimeters (LiF-TLD) at several organ sites using an Alderson-Rando phantom.
RESULTS: LiF-TLD measurements resulted in effective doses of 1.7 mSv for CT, 1.9 mSv for CTA of intracranial vessels, and 2.8 mSv for CTA of cervical vessels, respectively. Depending on examination parameters, effective doses varied between 1.1 and 5.0 mSv for cerebral CTP. For CTP, local doses in the area of the primary beam ranged between 114 and 444 mGy.
CONCLUSIONS: Comprehensive stroke imaging may result in up to 9.5 mSv with possible local doses of 490 mGy. Although critical doses for organ damage (eg, cataract formation or hair loss) are not reached, physicians need to be aware of possible radiation induced sequelae particularly in repetitive examinations.

Entities:  

Mesh:

Year:  2006        PMID: 16971627      PMCID: PMC8139787     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  35 in total

1.  Radiation-induced temporary hair loss as a radiation damage only occurring in patients who had the combination of MDCT and DSA.

Authors:  Yoshimasa Imanishi; Atsushi Fukui; Hiroshi Niimi; Daisuke Itoh; Kyouko Nozaki; Shunsuke Nakaji; Kumiko Ishizuka; Hitoshi Tabata; Yu Furuya; Masahiko Uzura; Hideto Takahama; Suzuo Hashizume; Shiro Arima; Yasuo Nakajima
Journal:  Eur Radiol       Date:  2004-09-04       Impact factor: 5.315

2.  Average radiation dose in standard CT examinations of the head: results of the 1990 NEXT survey.

Authors:  B J Conway; J L McCrohan; R G Antonsen; F G Rueter; R J Slayton; O H Suleiman
Journal:  Radiology       Date:  1992-07       Impact factor: 11.105

Review 3.  Brain perfusion: computed tomography applications.

Authors:  K A Miles
Journal:  Neuroradiology       Date:  2004-12       Impact factor: 2.804

4.  Quantitative assessment of the ischemic brain by means of perfusion-related parameters derived from perfusion CT.

Authors:  M Koenig; M Kraus; C Theek; E Klotz; W Gehlen; L Heuser
Journal:  Stroke       Date:  2001-02       Impact factor: 7.914

5.  Radiation doses to infants and adults undergoing head CT examinations.

Authors:  W Huda; C C Chamberlain; A E Rosenbaum; W Garrisi
Journal:  Med Phys       Date:  2001-03       Impact factor: 4.071

6.  Diffusion- and perfusion-weighted MRI. The DWI/PWI mismatch region in acute stroke.

Authors:  T Neumann-Haefelin; H J Wittsack; F Wenserski; M Siebler; R J Seitz; U Mödder; H J Freund
Journal:  Stroke       Date:  1999-08       Impact factor: 7.914

Review 7.  Computed tomographic angiography and computed tomographic perfusion imaging of hyperacute stroke.

Authors:  M H Lev; S J Nichols
Journal:  Top Magn Reson Imaging       Date:  2000-10

8.  A method for reducing radiation dose in cerebral CT perfusion study with variable scan schedule.

Authors:  Masaaki Hirata; Kenya Murase; Yoshifumi Sugawara; Takafumi Nanjo; Teruhito Mochizuki
Journal:  Radiat Med       Date:  2005-05

9.  [Quantitative perfusion imaging by multi-slice CT in stroke patients].

Authors:  G Bohner; A Förschler; B Hamm; R Lehmann; R Klingebiel
Journal:  Rofo       Date:  2003-06

10.  Perfusion CT of the brain: diagnostic approach for early detection of ischemic stroke.

Authors:  M Koenig; E Klotz; B Luka; D J Venderink; J F Spittler; L Heuser
Journal:  Radiology       Date:  1998-10       Impact factor: 11.105

View more
  54 in total

1.  A comparison of radiation exposure between diagnostic CTA and DSA examinations of cerebral and cervicocerebral vessels.

Authors:  A-L Manninen; J-M Isokangas; A Karttunen; T Siniluoto; M T Nieminen
Journal:  AJNR Am J Neuroradiol       Date:  2012-06-14       Impact factor: 3.825

2.  Neuroimaging by 320-row CT: is there a diagnostic benefit or is it just another scanner? A retrospective evaluation of 60 consecutive acute neurological patients.

Authors:  Eberhard Siebert; Georg Bohner; Florian Masuhr; Katrin Deuschle; Susanne Diekmann; Edzard Wiener; Hans-Christian Bauknecht; Randolf Klingebiel
Journal:  Neurol Sci       Date:  2010-05-28       Impact factor: 3.307

3.  Optimization of beam quality for photon-counting spectral computed tomography in head imaging: simulation study.

Authors:  Han Chen; Cheng Xu; Mats Persson; Mats Danielsson
Journal:  J Med Imaging (Bellingham)       Date:  2015-11-06

4.  From flatland to the fourth dimension.

Authors:  Christopher H Marshall
Journal:  AJNR Am J Neuroradiol       Date:  2006-09       Impact factor: 3.825

5.  Radiation doses of cerebral blood volume measurements using C-arm CT: A phantom study.

Authors:  W F Chu; C J Lin; W S Chen; S C Hung; C F Chiu; T H Wu; W Y Guo
Journal:  AJNR Am J Neuroradiol       Date:  2013-12-26       Impact factor: 3.825

6.  Appropriate use of CT perfusion following aneurysmal subarachnoid hemorrhage: a Bayesian analysis approach.

Authors:  R P Killeen; A Gupta; H Delaney; C E Johnson; A J Tsiouris; J Comunale; M E Fink; H S Mangat; A Z Segal; A I Mushlin; P C Sanelli
Journal:  AJNR Am J Neuroradiol       Date:  2013-11-07       Impact factor: 3.825

7.  Dynamic CT angiography and CT perfusion employing a 320-detector row CT: protocol and current clinical applications.

Authors:  Eric J Salomon; Joe Barfett; Peter W A Willems; Sasikhan Geibprasert; Susanna Bacigaluppi; Timo Krings
Journal:  Klin Neuroradiol       Date:  2009-08-23

8.  Radiation dose reduction in time-resolved CT angiography using highly constrained back projection reconstruction.

Authors:  Mark Supanich; Yinghua Tao; Brian Nett; Kari Pulfer; Jiang Hsieh; Patrick Turski; Charles Mistretta; Howard Rowley; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2009-06-30       Impact factor: 3.609

9.  Nonconvex prior image constrained compressed sensing (NCPICCS): theory and simulations on perfusion CT.

Authors:  J C Ramirez-Giraldo; J Trzasko; S Leng; L Yu; A Manduca; C H McCollough
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

Review 10.  [Neurologic emergencies and multislice computed tomography].

Authors:  L Eftimov; D Morhard; M Reiser; B Ertl-Wagner
Journal:  Radiologe       Date:  2009-06       Impact factor: 0.635

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.