Literature DB >> 11318321

Radiation doses to infants and adults undergoing head CT examinations.

W Huda1, C C Chamberlain, A E Rosenbaum, W Garrisi.   

Abstract

For routine noncontrast CT examinations of the head, we compared the radiation doses of infant patients aged no more than two years old, with those of "adults" defined as any patient whose weight was greater than 40 kg. Data were obtained for 23 infants, and an equal number of "adults," who underwent CT head examinations between May 1997 and March 1998. Patient CT data acquired included the x-ray tube potential (kVp), mAs, section thickness, and total number of sections. For radiation dosimetry purposes, the head was modeled as a uniform cylinder of water using patient size data obtained from a representative cross-sectional image. CT techniques and patient size data permitted the computation of the mean section doses in the head region, total energy imparted, and the corresponding effective doses. All CT scans were performed at 120 kVp, with an average current-exposure time product of 271 +/- 73 and 340 +/- 0 mAs for infants and "adults," respectively. The radius of the water cylinder used to model the patient head increased from 58 mm for 4 kg newborns to 70 mm for 8 kg infants. For "adults," there was little correlation between the weight of the patient and the mean water equivalent radius of 88 mm (r2 = 0.14). Mean section doses were 44.4 +/- 11.1 mGy for infants, and 44.2 +/- 1.5 mGy for "adults." The energy imparted to infants correlated with patient weight (r2= 0.35) much more than did that of "adults" (r2= 0.02). The average infant energy imparted (66.4 +/- 28.7 mJ) was approximately half the value obtained for "adults" (140 +/- 10 mJ). The average effective dose to the infants (7.6 +/- 3.1 mSv), however, was approximately six times higher than that for "adults" (1.3 +/- 0.1 mSv). There was no significant correlation between patient effective dose and patient mass for either the infant (r2 = 0.12) or the "adult" group of patients (r2= 0.02). Infant doses varied much more than "adult" doses, primarily because of a wider range of x-ray technique factors selected and secondarily due to the variation in infant head size. The observed variability in the computed radiation dose parameters indicates that it should be possible to reduce infant doses routinely in head CT examinations without any adverse effect on diagnostic imaging performance. For such routine head CT scans, the average dose reduction for infants weighing between 4 and 8 kg would be expected to range between 40% and 60%.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11318321     DOI: 10.1118/1.1350435

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  11 in total

1.  Strategies of dose reduction.

Authors:  Donald P Frush
Journal:  Pediatr Radiol       Date:  2002-03-07

2.  Effective doses to adult and pediatric patients.

Authors:  Walter Huda
Journal:  Pediatr Radiol       Date:  2002-03-06

3.  Radiation exposure of patients in comprehensive computed tomography of the head in acute stroke.

Authors:  M Cohnen; H-J Wittsack; S Assadi; K Muskalla; A Ringelstein; L W Poll; A Saleh; U Mödder
Journal:  AJNR Am J Neuroradiol       Date:  2006-09       Impact factor: 3.825

4.  Prospective, multireader evaluation of image quality and vascular delineation of multislice CT angiography of the brain.

Authors:  Birgit B Ertl-Wagner; Roland Bruening; Jeffrey Blume; Ralf-Thorsten Hoffmann; Brad Snyder; Karin A Herrmann; Maximilian F Reiser
Journal:  Eur Radiol       Date:  2005-03-19       Impact factor: 5.315

Review 5.  Anniversary paper. Development of x-ray computed tomography: the role of medical physics and AAPM from the 1970s to present.

Authors:  Xiaochuan Pan; Jeffrey Siewerdsen; Patrick J La Riviere; Willi A Kalender
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

Review 6.  Pediatric CT radiation exposure: where we were, and where we are now.

Authors:  Thomas R Goodman; Adel Mustafa; Erin Rowe
Journal:  Pediatr Radiol       Date:  2019-03-29

7.  Estimation of effective dose and lifetime attributable risk from multiple head CT scans in ventriculoperitoneal shunted children.

Authors:  J Aw-Zoretic; D Seth; G Katzman; S Sammet
Journal:  Eur J Radiol       Date:  2014-07-16       Impact factor: 3.528

8.  Absence of leukaemic fusion gene transcripts in preterm infants exposed to diagnostic x rays.

Authors:  P F Ravetto; R Agarwal; M L Chiswick; S W D'Souza; O B Eden; G M Taylor
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2003-05       Impact factor: 5.747

9.  Effective dose estimation in whole-body multislice CT in paediatric trauma patients.

Authors:  Robin D Munk; Peter C Strohm; Ulrich Saueressig; Joern Zwingmann; Markus Uhl; Norbert P Südkamp; Elmar Kotter; Mathias Langer; Thorsten A Bley
Journal:  Pediatr Radiol       Date:  2009-01-16

10.  Radiation doses to children with shunt-treated hydrocephalus.

Authors:  Lise Jofrid Holmedal; Eva Godske Friberg; Ingelin Børretzen; Hilde Olerud; Liv Laegreid; Karen Rosendahl
Journal:  Pediatr Radiol       Date:  2007-10-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.