Literature DB >> 12811694

[Quantitative perfusion imaging by multi-slice CT in stroke patients].

G Bohner1, A Förschler, B Hamm, R Lehmann, R Klingebiel.   

Abstract

OBJECTIVES: Evaluation of a parametric deconvolution algorithm (DA) in the diagnostic assessment of stroke patients by multi- slice spiral computed tomography (MS-CT).
MATERIAL AND METHODS: 52 patients (age range 34 - 89 years) with clinically suspected acute ischemia of one hemisphere and no infarct demarcation on plain cerebral CT underwent CT perfusion (CTP), performed on average 3.4 hours after the onset of symptoms by using MS-CT (4 x 8 mm scan volume). Using a DA-based software module, perfusion images of the cerebral blood perfusion (CBP), cerebral blood volume (CBV) and mean transit time (MTT) were calculated and assessed by two readers for visually apparent perfusion abnormalities. Amount and extension of perfusion disturbances were measured and correlated with the outcome.
RESULTS: Of 44 patients, in whom perfusion maps could be generated, territorial infarction was confirmed by follow-up in 22 subjects. With a sensitivity of 95 % ischemia could be detected on MTT-maps (CBP 91 %, CBV 77 %). Specificity was highest (100 %) for CBV-maps. Patients with infarction showed significant (p < 0.001) reduction of CBP (10.7 vs. 38.3 ml/100 ml/min), CBV (1.3 vs. 2.3 ml/100 ml) and prolongation of MTT (12.3 vs. 4.3 s) compared to the contralateral hemisphere, whereas in patients without infarction no significant changes were found. Extension of CBV reduction showed the best correlation (r = 0.82) with final infarct volume.
CONCLUSION: The DA-based CTP protocol evaluated in this study is a suitable tool for the early identification and quantification of acute cerebral ischemia.

Entities:  

Mesh:

Year:  2003        PMID: 12811694     DOI: 10.1055/s-2003-39928

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  3 in total

1.  Radiation exposure of patients in comprehensive computed tomography of the head in acute stroke.

Authors:  M Cohnen; H-J Wittsack; S Assadi; K Muskalla; A Ringelstein; L W Poll; A Saleh; U Mödder
Journal:  AJNR Am J Neuroradiol       Date:  2006-09       Impact factor: 3.825

2.  Dose exposure of patients undergoing comprehensive stroke imaging by multidetector-row CT: comparison of 320-detector row and 64-detector row CT scanners.

Authors:  S Diekmann; E Siebert; R Juran; M Roll; W Deeg; H-C Bauknecht; F Diekmann; R Klingebiel; G Bohner
Journal:  AJNR Am J Neuroradiol       Date:  2010-01-28       Impact factor: 3.825

3.  Functional cluster analysis of CT perfusion maps: a new tool for diagnosis of acute stroke?

Authors:  Christian Baumgartner; Kurt Gautsch; Christian Böhm; Stephan Felber
Journal:  J Digit Imaging       Date:  2005-09       Impact factor: 4.056

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.