Literature DB >> 15351903

Radiation-induced temporary hair loss as a radiation damage only occurring in patients who had the combination of MDCT and DSA.

Yoshimasa Imanishi1, Atsushi Fukui, Hiroshi Niimi, Daisuke Itoh, Kyouko Nozaki, Shunsuke Nakaji, Kumiko Ishizuka, Hitoshi Tabata, Yu Furuya, Masahiko Uzura, Hideto Takahama, Suzuo Hashizume, Shiro Arima, Yasuo Nakajima.   

Abstract

As imaging technologies become increasingly advanced, it is possible to obtain detailed morphological information as well as functional imaging data. In some imaging technologies, the radiation dose increases with the ability to obtain better images or more detailed information. We encountered three cases of temporary bandage-shaped hair loss, which was caused by perfusion studies of the head by multi-detector row computed tomography (MDCT) for evaluation of cerebral blood flow in patients with vascular disorders. In all three patients with temporary hair loss, two angiographies of the head had been performed in the period of serial CT examinations. This suggested the possibility that radiation exposure from angiography performed in serial examinations, combined with the perfusion studies of the head with MDCT, played an important role in this temporary, bandage-shaped hair loss. Radiologists should be aware that a cumulative or multiplier effect of radiation exposure from multiple diagnostic techniques may result in hair loss and other types of radiation complications.

Entities:  

Mesh:

Year:  2004        PMID: 15351903     DOI: 10.1007/s00330-004-2459-1

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  13 in total

1.  Radiation exposure during cardiac CT: effective doses at multi-detector row CT and electron-beam CT.

Authors:  Peter Hunold; Florian M Vogt; Axel Schmermund; Jörg F Debatin; Gert Kerkhoff; Thomas Budde; Raimund Erbel; Klaus Ewen; Jörg Barkhausen
Journal:  Radiology       Date:  2003-01       Impact factor: 11.105

Review 2.  Multislice CT: update on radiation and screening.

Authors:  Mannudeep K Kalra; Michael M Maher; Sanjay Saini
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

Review 3.  Quantitative assessment of regional cerebral blood flows by perfusion CT studies at low injection rates: a critical review of the underlying theoretical models.

Authors:  M Wintermark; P Maeder; J P Thiran; P Schnyder; R Meuli
Journal:  Eur Radiol       Date:  2001       Impact factor: 5.315

Review 4.  Radiotherapy and radiosurgical management of brain metastases.

Authors:  J C Flickinger
Journal:  Curr Oncol Rep       Date:  2001-11       Impact factor: 5.075

Review 5.  Nonstochastic effects of ionizing radiation.

Authors: 
Journal:  Ann ICRP       Date:  1984

6.  Using 80 kVp versus 120 kVp in perfusion CT measurement of regional cerebral blood flow.

Authors:  M Wintermark; P Maeder; F R Verdun; J P Thiran; J F Valley; P Schnyder; R Meuli
Journal:  AJNR Am J Neuroradiol       Date:  2000 Nov-Dec       Impact factor: 3.825

7.  CT scanning: patterns of use and dose.

Authors:  F A Mettler; P W Wiest; J A Locken; C A Kelsey
Journal:  J Radiol Prot       Date:  2000-12       Impact factor: 1.394

8.  Absorbed dose and deterministic effects to patients from interventional neuroradiology.

Authors:  R B Mooney; C S McKinstry; H A Kamel
Journal:  Br J Radiol       Date:  2000-07       Impact factor: 3.039

9.  [Radiation-induced temporary hair loss after endovascular embolization of the cerebral arteries: six cases].

Authors:  M D'incan; H Roger; J Gabrillargues; S Mansard; S Parent; J Chazal; B Irthum; P Souteyrand
Journal:  Ann Dermatol Venereol       Date:  2002-05       Impact factor: 0.777

10.  Non-traumatic neurological emergencies: imaging of cerebral ischemia.

Authors:  Iris Grunwald; Wolfgang Reith
Journal:  Eur Radiol       Date:  2002-05-30       Impact factor: 5.315

View more
  35 in total

1.  In-patient to isocenter KERMA ratios in CT.

Authors:  Walter Huda; Kent M Ogden; Robert L Lavallee; Marsha L Roskopf; Ernest M Scalzetti
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

2.  A comparison of radiation exposure between diagnostic CTA and DSA examinations of cerebral and cervicocerebral vessels.

Authors:  A-L Manninen; J-M Isokangas; A Karttunen; T Siniluoto; M T Nieminen
Journal:  AJNR Am J Neuroradiol       Date:  2012-06-14       Impact factor: 3.825

3.  Estimation of tissue perfusion by dynamic contrast-enhanced imaging: simulation-based evaluation of the steepest slope method.

Authors:  Gunnar Brix; Stefan Zwick; Jürgen Griebel; Christian Fink; Fabian Kiessling
Journal:  Eur Radiol       Date:  2010-04-21       Impact factor: 5.315

4.  Cumulative radiation dose during hospitalization for aneurysmal subarachnoid hemorrhage.

Authors:  S I Moskowitz; W J Davros; M E Kelly; D Fiorella; P A Rasmussen; T J Masaryk
Journal:  AJNR Am J Neuroradiol       Date:  2010-05-27       Impact factor: 3.825

5.  Optimization of beam quality for photon-counting spectral computed tomography in head imaging: simulation study.

Authors:  Han Chen; Cheng Xu; Mats Persson; Mats Danielsson
Journal:  J Med Imaging (Bellingham)       Date:  2015-11-06

6.  Reduced-dose CT protocol for the assessment of cerebral vasospasm.

Authors:  N Bricout; L Estrade; F Boustia; E Kalsoum; J P Pruvo; X Leclerc
Journal:  Neuroradiology       Date:  2015-08-28       Impact factor: 2.804

7.  Radiation exposure of patients in comprehensive computed tomography of the head in acute stroke.

Authors:  M Cohnen; H-J Wittsack; S Assadi; K Muskalla; A Ringelstein; L W Poll; A Saleh; U Mödder
Journal:  AJNR Am J Neuroradiol       Date:  2006-09       Impact factor: 3.825

8.  Prospective, multireader evaluation of image quality and vascular delineation of multislice CT angiography of the brain.

Authors:  Birgit B Ertl-Wagner; Roland Bruening; Jeffrey Blume; Ralf-Thorsten Hoffmann; Brad Snyder; Karin A Herrmann; Maximilian F Reiser
Journal:  Eur Radiol       Date:  2005-03-19       Impact factor: 5.315

Review 9.  The effect of X-rays on bone: a pictorial review.

Authors:  H J Williams; A M Davies
Journal:  Eur Radiol       Date:  2005-10-20       Impact factor: 5.315

10.  From flatland to the fourth dimension.

Authors:  Christopher H Marshall
Journal:  AJNR Am J Neuroradiol       Date:  2006-09       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.