Literature DB >> 6478690

Stabilization of the lower thoracic and lumbar spine with external skeletal fixation.

F P Magerl.   

Abstract

For stabilization of the lower thoracic and lumbar spine, an external spinal skeletal fixation (ESSF) system has been developed and clinically used since 1977. The system consists of two pairs of Schanz screws and an adjustable external fixation device. The Schanz screws are firmly anchored through the pedicles into the vertebral bodies. Application of ESSF offers some unique characteristics beneficial in the treatment of unstable spinal injuries and spinal osteomyelitis. In contrast to other fixation systems, the number of vertebrae immobilized can be reduced with ESSF. Versatility of the system allows application in every type of spinal instability. Stability obtained with ESSF suffices for early mobilization without major external support in every instance. In laboratory investigation, ESSF proved to be more secure than rod distraction systems and plate fixation. Since 1977, 65 patients were treated with ESSF. All 52 patients who were at least one year postsurgery were personally examined. This group included 42 patients with acute spinal trauma and eight patients with spinal osteomyelitis. Results achieved with ESSF have been encouraging, with no serious complications to date. Future modifications of ESSF application could lead to simplification and facilitation of treatment.

Entities:  

Mesh:

Year:  1984        PMID: 6478690

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  102 in total

1.  Translaminar screw fixation of the lumbar spine.

Authors:  D Grob; M Rubeli; H J Scheier; J Dvorak
Journal:  Int Orthop       Date:  1992       Impact factor: 3.075

2.  Cortical and Standard Trajectory Pedicle Screw Fixation Techniques in Stabilizing Multisegment Lumbar Spine with Low Grade Spondylolisthesis.

Authors:  Wayne K Cheng; Serkan İnceoğlu
Journal:  Int J Spine Surg       Date:  2015-08-31

3.  Neurological recovery and its influencing factors in thoracic and lumbar spine fractures after surgical decompression and stabilization.

Authors:  Stefan Arthur Rath; John Festo Kahamba; Thomas Kretschmer; Ulrich Neff; Hans-Peter Richter; Gregor Antoniadis
Journal:  Neurosurg Rev       Date:  2004-10-06       Impact factor: 3.042

4.  Intraoperative monitoring of segmental spinal nerve root function with free-run and electrically-triggered electromyography and spinal cord function with reflexes and F-responses. A position statement by the American Society of Neurophysiological Monitoring.

Authors:  Ronald E Leppanen
Journal:  J Clin Monit Comput       Date:  2006-01-25       Impact factor: 2.502

5.  Biomechanical analysis of differing pedicle screw insertion angles.

Authors:  William Sterba; Do-Gyoon Kim; David P Fyhrie; Yener N Yeni; Rahul Vaidya
Journal:  Clin Biomech (Bristol, Avon)       Date:  2007-01-08       Impact factor: 2.063

6.  Transforaminal lumbar interbody fusion using unilateral pedicle screws and a translaminar screw.

Authors:  Anil Sethi; Sandra Lee; Rahul Vaidya
Journal:  Eur Spine J       Date:  2008-11-18       Impact factor: 3.134

7.  Inserting pedicle screws in lumbar spondylolisthesis - The easy bone conserving way.

Authors:  Hitesh Lal; Lalit Kumar; Ramesh Kumar; Tankeshwar Boruah; Pankaj Kumar Jindal; Vinod Kumar Sabharwal
Journal:  J Clin Orthop Trauma       Date:  2017-03-06

8.  [Surgical treatment of thoracolumbar spinal fractures with internal fixator and transpedicular spongiosa-plasty].

Authors:  U Liljenqvist; U Mommsen
Journal:  Unfallchirurgie       Date:  1995-02

9.  Comparison of clinical results between novel percutaneous pedicle screw and traditional open pedicle screw fixation for thoracolumbar fractures without neurological deficit.

Authors:  Ming Yang; Qinpeng Zhao; Dingjun Hao; Zhen Chang; Shichang Liu; Xinhua Yin
Journal:  Int Orthop       Date:  2018-06-16       Impact factor: 3.075

10.  Reduction and stabilization of lumbar and thoracolumbar spine fractures with Louis' plates and internal fixator: a comparative study.

Authors:  P Zangger; T Pache
Journal:  Eur Spine J       Date:  1993-10       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.