Literature DB >> 16964863

Development and application of a real-time monitoring and feedback system for deep inspiration breath hold based on external marker tracking.

Markus Stock1, Kristina Kontrisova, Karin Dieckmann, Joachim Bogner, Richard Poetter, Dietmar Georg.   

Abstract

Respiration can cause tumor movements in thoracic regions of up to 3 cm. To minimize motion effects several approaches, such as gating and deep inspiration breath hold (DIBH), are still under development. The goal of our study was to develop and evaluate a noninvasive system for gated DIBH (GDIBH) based on external markers. DIBH monitoring was based on an infrared tracking system and an in-house-developed software. The in-house software provided the breathing curve in real time and was used as on-line information for a prototype of a feedback device. Reproducibility and stability of the breath holds were evaluated without and with feedback. Thirty-five patients undergoing stereotactic body radiotherapy (SBRT) performed DIBH maneuvers after each treatment. For 16 patients dynamic imaging sequences on a multislice CT were used to determine the correlation between tumor and external markers. The relative reproducibility of DIBH maneuvers was improved with the feedback device (74.5% +/- 17.1% without versus 93.0% +/- 4.4% with feedback). The correlation between tumor and marker was good (Pearson correlation coefficient 0.83 +/- 0.17). The regression slopes showed great intersubject variability but on average the internal margin in a DIBH treatment situation could be theoretically reduced by 3 mm with the feedback device. DIBH monitoring could be realized in a noninvasive manner through external marker tracking. We conclude that reduction of internal margins can be achieved with a feedback system but should be performed with great care due to the individual behavior of target motion.

Entities:  

Mesh:

Year:  2006        PMID: 16964863     DOI: 10.1118/1.2219775

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  17 in total

1.  Monitoring of breathing phases using a bioacoustic method in healthy awake subjects.

Authors:  Hisham Alshaer; Geoffrey R Fernie; T Douglas Bradley
Journal:  J Clin Monit Comput       Date:  2011-09-29       Impact factor: 2.502

2.  Motion management strategies and technical issues associated with stereotactic body radiotherapy of thoracic and upper abdominal tumors: A review from NRG oncology.

Authors:  Edward D Brandner; Indrin J Chetty; Tawfik G Giaddui; Ying Xiao; M Saiful Huq
Journal:  Med Phys       Date:  2017-04-20       Impact factor: 4.071

3.  Capacitive monitoring system for real-time respiratory motion monitoring during radiation therapy.

Authors:  Parisa Sadeghi; Kathryn Moran; James L Robar
Journal:  J Appl Clin Med Phys       Date:  2020-07-09       Impact factor: 2.102

4.  Respiratory motion management using audio-visual biofeedback for respiratory-gated radiotherapy of synchrotron-based pulsed heavy-ion beam delivery.

Authors:  Pengbo He; Qiang Li; Xinguo Liu; Zhongying Dai; Ting Zhao; Tingyan Fu; Guosheng Shen; Yuanyuan Ma; Qiyan Huang; Yuanlin Yan
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

5.  Management of three-dimensional intrafraction motion through real-time DMLC tracking.

Authors:  Amit Sawant; Raghu Venkat; Vikram Srivastava; David Carlson; Sergey Povzner; Herb Cattell; Paul Keall
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

Review 6.  Measuring cerebrovascular reactivity: what stimulus to use?

Authors:  J Fierstra; O Sobczyk; A Battisti-Charbonney; D M Mandell; J Poublanc; A P Crawley; D J Mikulis; J Duffin; J A Fisher
Journal:  J Physiol       Date:  2013-09-30       Impact factor: 5.182

7.  A study on the influence of breathing phases in intensity-modulated radiotherapy of lung tumours using four-dimensional CT.

Authors:  W C Wu; C L Chan; Y W Wong; J P Cuijpers
Journal:  Br J Radiol       Date:  2009-09-01       Impact factor: 3.039

8.  Validity of the use of nose tip motion as a surrogate for intracranial motion in mask-fixated frameless Gamma Knife® Icon™ therapy.

Authors:  Gavin Wright; Natalie Harrold; Paul Hatfield; Peter Bownes
Journal:  J Radiosurg SBRT       Date:  2017

9.  Fidelity of dose delivery at high dose rate of volumetric modulated arc therapy in a truebeam linac with flattening filter free beams.

Authors:  Georgios Kalantzis; Jianguo Qian; Bin Han; Gary Luxton
Journal:  J Med Phys       Date:  2012-10

10.  Monitoring tumor motion by real time 2D/3D registration during radiotherapy.

Authors:  Christelle Gendrin; Hugo Furtado; Christoph Weber; Christoph Bloch; Michael Figl; Supriyanto Ardjo Pawiro; Helmar Bergmann; Markus Stock; Gabor Fichtinger; Dietmar Georg; Wolfgang Birkfellner
Journal:  Radiother Oncol       Date:  2011-08-30       Impact factor: 6.280

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.