Literature DB >> 21956580

Monitoring of breathing phases using a bioacoustic method in healthy awake subjects.

Hisham Alshaer1, Geoffrey R Fernie, T Douglas Bradley.   

Abstract

OBJECTIVE: To test the ability of a microphone recording system, located distal to the respiratory outflow tract, to track the timing of the inspiratory and expiratory phases of breathing in awake healthy subjects. <br> METHODS: Fifteen subjects participated. Breath sounds were recorded using a microphone embedded in a face frame in a fixed location in relation to the nostrils and mouth, while simultaneously recording respiratory movements by respiratory inductance plethysmography (RIP). Subjects were studied while supine and were instructed to breathe normally for 2 min: through their noses only (nasal breathing), during the first min, and through their mouths only (oral breathing) during the second min. Five subjects (test group) were chosen randomly to extract features from their acoustic data. Ten breaths (5 nasal and 5 oral breaths) from each subject were studied. Inspiratory and expiratory segments of breath sounds were determined and extracted from the acoustic data by comparing it to the RIP trace. Subsequently, the frequency spectrum of each phase was then determined. Spectral variables derived from the 5 test subjects were applied prospectively to detect breathing phases in the remaining 10 subjects (validation group). <br> RESULTS: Test group data showed that the mean of all inspiratory spectra peaked between 30 and 270 Hz, flattened between 300 and 1,100 Hz, and peaked again with a center frequency of 1,400 Hz. The expiratory spectra peaked between 30 and 180 Hz and its power dropped off exponentially after that. Accordingly, the bands ratio (BR) of frequency magnitudes between 500 and 2500 Hz to frequency magnitudes between 0 and 500 Hz was chosen as a feature to distinguish between breathing phases. BR for the mean inspiratory spectrum was 2.27 and for the mean expiratory spectrum was 0.15. The route of breathing did not affect the BR ratio within the same phase. When this BR was applied to 436 breathing phases in the validation group, 424 (97%) were correctly identified (Kappa = 0.96, P < 0.001) indicating strong agreement between the acoustic method and the RIP. <br> CONCLUSION: Frequency spectra of breathing sounds recorded from a face-frame, reliably identified the inspiratory and expiratory phases of breathing. This technique may have various applications for respiratory monitoring and analysis.

Entities:  

Mesh:

Year:  2011        PMID: 21956580     DOI: 10.1007/s10877-011-9307-z

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  26 in total

Review 1.  Critical review of non-invasive respiratory monitoring in medical care.

Authors:  M Folke; L Cernerud; M Ekström; B Hök
Journal:  Med Biol Eng Comput       Date:  2003-07       Impact factor: 2.602

2.  Development and application of a real-time monitoring and feedback system for deep inspiration breath hold based on external marker tracking.

Authors:  Markus Stock; Kristina Kontrisova; Karin Dieckmann; Joachim Bogner; Richard Poetter; Dietmar Georg
Journal:  Med Phys       Date:  2006-08       Impact factor: 4.071

3.  Analysis of wheezes in asthmatic patients during spontaneous respiration.

Authors:  R Jané; S Cortés; J A Fiz; J Morera
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2004

Review 4.  Respiratory monitoring in the intensive care unit.

Authors:  M J Tobin
Journal:  Am Rev Respir Dis       Date:  1988-12

5.  A bioacoustic method for timing of respiration at cardiac investigations.

Authors:  C Xiong; B Hök; T Strömberg; D Loyd; B Wranne; P Ask
Journal:  Clin Physiol       Date:  1995-03

6.  Acoustic analysis of snoring sound in patients with simple snoring and obstructive sleep apnoea.

Authors:  J A Fiz; J Abad; R Jané; M Riera; M A Mañanas; P Caminal; D Rodenstein; J Morera
Journal:  Eur Respir J       Date:  1996-11       Impact factor: 16.671

7.  Problems in timing of respiration with the nasal thermistor technique.

Authors:  C Xiong; B J Sjöberg; P Sveider; P Ask; D Loyd; B Wranne
Journal:  J Am Soc Echocardiogr       Date:  1993 Mar-Apr       Impact factor: 5.251

8.  Modeling of pulmonary crackles using wavelet networks.

Authors:  M Yeginer; Y Kahya
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2005

9.  A new respiratory rate monitor: development and initial clinical experience.

Authors:  B Hök; L Wiklund; S Henneberg
Journal:  Int J Clin Monit Comput       Date:  1993-05

10.  The occurrence of sleep-disordered breathing among middle-aged adults.

Authors:  T Young; M Palta; J Dempsey; J Skatrud; S Weber; S Badr
Journal:  N Engl J Med       Date:  1993-04-29       Impact factor: 91.245

View more
  3 in total

1.  A multi-channel acoustics monitor for perioperative respiratory monitoring: preliminary data.

Authors:  Kamal Jafarian; Majid Amineslami; Kamran Hassani; Mahdi Navidbakhsh; Mohammad Niakan Lahiji; D John Doyle
Journal:  J Clin Monit Comput       Date:  2015-04-14       Impact factor: 2.502

2.  Detecting unilateral phrenic paralysis by acoustic respiratory analysis.

Authors:  José Antonio Fiz; Raimon Jané; Manuel Lozano; Rosa Gómez; Juan Ruiz
Journal:  PLoS One       Date:  2014-04-09       Impact factor: 3.240

3.  A method to assess adherence in inhaler use through analysis of acoustic recordings of inhaler events.

Authors:  Shona D'Arcy; Elaine MacHale; Jansen Seheult; Martin S Holmes; Cian Hughes; Imran Sulaiman; Deirdre Hyland; Conor O'Reilly; Senan Glynn; Thekra Al-Zaabi; John McCourt; Terence Taylor; Frank Keane; Isabelle Killane; Richard B Reilly; Richard W Costello
Journal:  PLoS One       Date:  2014-06-06       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.