Assessment of the abdominal aorta and its visceral branches by contrast-enhanced dynamic volumetric hepatic parallel magnetic resonance imaging: feasibility, reliability and accuracy.

Robert Werder1, Daniel Nanz, Amelie M Lutz, Dominik Weishaupt, Lucas McCormack, Burkhardt Seifert, Borut Marincek, Jürgen K Willmann.   

Abstract

The purpose of this study was to evaluate a new three-dimensional gradient-echo (GRE) MR sequence performed with a parallel acquisition technique to shorten breath-hold times (parallel GRE MRI) in the detection of arterial variants and stenosis of the abdominal aorta and its visceral branches. A total of 102 patients underwent dynamic parallel GRE MRI, timed to the arterial phase by a test bolus (mean breath-hold time, 17 s). For both quantitative and qualitative analysis, the abdominal aorta and its visceral branches were divided into 13 arterial segments. In a subanalysis of 55/102 patients, the accuracy of parallel GRE MRI compared to MDCT in the detection arterial variants and stenosis was calculated for two independent readers. Mean SNRs and CNRs were 47.2 and 35.6, respectively. Image quality was rated good or excellent in 1,234/1,326 segments (93%). Hepatic and renal arterial variants were identified with an accuracy of 93 and 95%, respectively (reader 1) and 98 and 100%, respectively (reader 2). Both readers detected arterial stenosis with an accuracy of 98%. Interobserver agreement was good to excellent for the detection of hepatic (kappa=0.69) and renal (kappa=0.92) variants and for the diagnosis of stenosis (kappa=0.96). Dynamic three-dimensional parallel GRE MRI is feasible and allows a reliable and accurate diagnosis of arterial variants and stenosis of the abdominal aorta and its visceral branches in a short breath-hold-time.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16947013     DOI: 10.1007/s00330-006-0384-1

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  23 in total

1.  Hepatic MR imaging with a dynamic contrast-enhanced isotropic volumetric interpolated breath-hold examination: feasibility, reproducibility, and technical quality.

Authors:  V S Lee; M T Lavelle; N M Rofsky; G Laub; D M Thomasson; G A Krinsky; J C Weinreb
Journal:  Radiology       Date:  2000-05       Impact factor: 11.105

2.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

Review 3.  Kidney transplantation: evaluation of donors and recipients.

Authors:  Douglas Rusnack; Gary M Israel
Journal:  Magn Reson Imaging Clin N Am       Date:  2004-08       Impact factor: 2.266

4.  Parallel acquisition techniques for accelerated volumetric interpolated breath-hold examination magnetic resonance imaging of the upper abdomen: assessment of image quality and lesion conspicuity.

Authors:  Florian M Vogt; Gerald Antoch; Peter Hunold; Stefan Maderwald; Mark E Ladd; Jörg F Debatin; Stefan G Ruehm
Journal:  J Magn Reson Imaging       Date:  2005-04       Impact factor: 4.813

5.  Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays.

Authors:  D K Sodickson; W J Manning
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

6.  An application of hierarchical kappa-type statistics in the assessment of majority agreement among multiple observers.

Authors:  J R Landis; G G Koch
Journal:  Biometrics       Date:  1977-06       Impact factor: 2.571

7.  Abdominal MR imaging with a volumetric interpolated breath-hold examination.

Authors:  N M Rofsky; V S Lee; G Laub; M A Pollack; G A Krinsky; D Thomasson; M M Ambrosino; J C Weinreb
Journal:  Radiology       Date:  1999-09       Impact factor: 11.105

Review 8.  Contemporary imaging techniques for the diagnosis of renal artery stenosis.

Authors:  T Leiner; M W de Haan; P J Nelemans; J M A van Engelshoven; G B C Vasbinder
Journal:  Eur Radiol       Date:  2005-06-28       Impact factor: 5.315

9.  Intraindividual comparison of gadopentetate dimeglumine, gadobenate dimeglumine, and gadobutrol for pelvic 3D magnetic resonance angiography.

Authors:  Christoph U Herborn; Thomas C Lauenstein; Stefan G Ruehm; Silke Bosk; Jörg F Debatin; Mathias Goyen
Journal:  Invest Radiol       Date:  2003-01       Impact factor: 6.016

Review 10.  Preoperative hepatic vascular evaluation with CT and MR angiography: implications for surgery.

Authors:  Dushyant Sahani; Aparna Mehta; Michael Blake; Srinivasa Prasad; Gordan Harris; Sanjay Saini
Journal:  Radiographics       Date:  2004 Sep-Oct       Impact factor: 5.333

View more
  2 in total

1.  Carotid MR angiography with traditional bolus timing: clinical observations and Fourier-based modelling of contrast kinetics.

Authors:  Jan Menke
Journal:  Eur Radiol       Date:  2009-05-16       Impact factor: 5.315

2.  MR angiography with parallel acquisition for assessment of the visceral arteries: comparison with conventional MR angiography and 64-detector-row computed tomography.

Authors:  Reto Sutter; Christina Heilmaier; Amelie M Lutz; Dominik Weishaupt; Burkhardt Seifert; Jürgen K Willmann
Journal:  Eur Radiol       Date:  2009-06-13       Impact factor: 5.315