PURPOSE: To assess the feasibility of using magnetic resonance (MR) imaging to guide stent deployment in the pulmonary valve and artery and evaluate, after stent deployment, the position and morphology of and blood flow through the stent.
MATERIALS AND METHODS: Angiography and 1.5-T MR imaging were performed in a dual-imaging suite. Nitinol stents were placed in the pulmonary valve and main pulmonary artery in five pigs by using MR imaging guidance. For interactive MR imaging monitoring of catheter manipulation and stent delivery, balanced fast field-echo and T1-weighted turbo field-echo sequences were used. Visualization of the delivery system was based on T2* (with air as the contrast material) or T1 (with gadodiamide as the contrast material). After stent deployment, the position and morphology of and flow through the stent were verified with multiphase multisection balanced fast field-echo and velocity-encoded cine MR imaging. Findings at angiography and postmortem examination also helped verify stent placement. The paired Student t test was used for data analysis.
RESULTS: The stent was successfully deployed in all animals. The stent was placed distal to the pulmonary valve in four animals and across the pulmonary valve in one animal. The position and morphology of the stent were clearly depicted on balanced fast field-echo images. In the animal with the stent placed across the pulmonary valve, the pulmonary regurgitant fraction was 37%; this was not seen in the animals with stents placed distal to the pulmonary valve. No complication (eg, stent migration, intramural injury, or vascular perforation) was noted during the intervention. Findings at angiography and postmortem examination confirmed the position of the stents.
CONCLUSION: MR imaging has the potential to guide stent placement in the pulmonary valve or artery and to evaluate flow volume within the stent lumen after the intervention.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12563142     DOI: 10.1148/radiol.2262011639

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  25 in total

Review 1.  Right ventricular function late after total repair of tetralogy of Fallot.

Authors:  Alexander van Straten; Hubert W Vliegen; Mark G Hazekamp; Albert de Roos
Journal:  Eur Radiol       Date:  2005-02-22       Impact factor: 5.315

Review 2.  Cardiovascular interventional magnetic resonance imaging.

Authors:  Robert J Lederman
Journal:  Circulation       Date:  2005-11-08       Impact factor: 29.690

3.  Real-time magnetic resonance imaging to guide pediatric endovascular procedures.

Authors:  A N Raval; R J Lederman
Journal:  Pediatr Cardiol       Date:  2005 May-Jun       Impact factor: 1.655

4.  Magnetic resonance imaging guided catheterisation for assessment of pulmonary vascular resistance: in vivo validation and clinical application in patients with pulmonary hypertension.

Authors:  T Kuehne; S Yilmaz; I Schulze-Neick; E Wellnhofer; P Ewert; E Nagel; P Lange
Journal:  Heart       Date:  2005-08       Impact factor: 5.994

5.  Quantification of periprosthetic valve leakage with multiple regurgitation jets by magnetic resonance imaging.

Authors:  A Pflaumer; M Schwaiger; J Hess; R Lange; H Stern
Journal:  Pediatr Cardiol       Date:  2005 Sep-Oct       Impact factor: 1.655

Review 6.  Real-time, Interactive MRI for cardiovascular interventions.

Authors:  Elliot R McVeigh; Michael A Guttman; Peter Kellman; Amish N Raval; Robert J Lederman
Journal:  Acad Radiol       Date:  2005-09       Impact factor: 3.173

7.  Microcatheter tip enhancement in fluoroscopy: a comparison of techniques.

Authors:  Akihiro Takemura; Kenneth R Hoffmann; Masayuki Suzuki; Zhou Wang; Hussain S Rangwala; Hajime Harauchi; Stephen Rudin; Tokuo Umeda
Journal:  J Digit Imaging       Date:  2007-12       Impact factor: 4.056

8.  An algorithm for tracking microcatheters in fluoroscopy.

Authors:  Akihiro Takemura; Kenneth R Hoffmann; Masayuki Suzuki; Zhou Wang; Hussain S Rangwala; Hajime Harauchi; Stephen Rudin; Tokuo Umeda
Journal:  J Digit Imaging       Date:  2008-03       Impact factor: 4.056

9.  Real-time magnetic resonance imaging-guided endovascular recanalization of chronic total arterial occlusion in a swine model.

Authors:  Amish N Raval; Parag V Karmarkar; Michael A Guttman; Cengizhan Ozturk; Smita Sampath; Ranil DeSilva; Ronnier J Aviles; Minnan Xu; Victor J Wright; William H Schenke; Ozgur Kocaturk; Alexander J Dick; Venkatesh K Raman; Ergin Atalar; Elliot R McVeigh; Robert J Lederman
Journal:  Circulation       Date:  2006-02-20       Impact factor: 29.690

Review 10.  Interventional cardiovascular magnetic resonance imaging: a new opportunity for image-guided interventions.

Authors:  Christina E Saikus; Robert J Lederman
Journal:  JACC Cardiovasc Imaging       Date:  2009-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.