Determination of three-dimensional positions of known sparse objects from a single projection.

K R Hoffmann1, J Esthappan.   

Abstract

A new technique is developed for accurate determination of the three-dimensional position and orientation of known sparse objects, e.g., a configuration of points, from a single-perspective projection. In this technique, a computer model of the known object is translated and rotated so as to align it optimally in a least-squares sense with the projection lines connecting the image points with the focal spot by using a modification of the projection-Procrustes technique. The translational and rotational adjustments are repeated iteratively until the angular change between iterations is less than 0.25 degree. Simulations indicate that, for rms input image errors of 0.03 cm, the three-dimensional positions and orientations can be determined to within approximately 0.2 cm and 0.3 degree for a wide range of initially guessed positions and orientations, and positions can be determined with an accuracy of approximately 0.3 cm for objects having as few as four points. In phantom experiments, three-dimensional positions and orientations of a cube phantom were reproducibly determined to within 0.23 cm and 0.13 degree. The entire calculation requires only 10 s on a VAX 3500 to converge to the solution. The accuracy, precision, and speed of the technique indicate that it will be a useful tool for determination of three-dimensional positions and orientations of known sparse objects.

Mesh:

Year:  1997        PMID: 9127308     DOI: 10.1118/1.597938

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

Review 1.  Biplane X-ray angiograms, intravascular ultrasound, and 3D visualization of coronary vessels.

Authors:  K R Hoffmann; A Wahle; C Pellot-Barakat; J Sklansky; M Sonka
Journal:  Int J Card Imaging       Date:  1999-12

2.  Heart-surface reconstruction and ECG electrodes localization using fluoroscopy, epipolar geometry and stereovision: application to noninvasive imaging of cardiac electrical activity.

Authors:  Raja N Ghanem; Charulatha Ramanathan; Ping Jia; Yoram Rudy
Journal:  IEEE Trans Med Imaging       Date:  2003-10       Impact factor: 10.048

3.  Microcatheter tip enhancement in fluoroscopy: a comparison of techniques.

Authors:  Akihiro Takemura; Kenneth R Hoffmann; Masayuki Suzuki; Zhou Wang; Hussain S Rangwala; Hajime Harauchi; Stephen Rudin; Tokuo Umeda
Journal:  J Digit Imaging       Date:  2007-12       Impact factor: 4.056

4.  Pose determination of a cylindrical (dental) implant in three-dimensions from a single two-dimensional radiograph.

Authors:  R K W Schulze
Journal:  Dentomaxillofac Radiol       Date:  2010-01       Impact factor: 2.419

5.  Experimental comparison of cone beam CT (CBCT) reconstruction and multi-view reconstruction (MVR) for microangiography (MA) detector system.

Authors:  Vikas Patel; Andrew T Kuhls; Peter B Noël; Alan Walczak; Ciprian N Ionita; Ravishankar Chityala; Rekha Tranquebar; Hussain S Rangwala; Snehal S Kasodekar; Kenneth R Hoffmann; Daniel Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2006

6.  Rotational micro-CT using a clinical C-arm angiography gantry.

Authors:  V Patel; K R Hoffmann; C N Ionita; C Keleshis; D R Bednarek; S Rudin
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

7.  Standardization of three-dimensional pose of cylindrical implants from intraoral radiographs: a preliminary study.

Authors:  Saverio Cosola; Paolo Toti; Miguel Peñarrocha-Diago; Ugo Covani; Bruno Carlo Brevi; David Peñarrocha-Oltra
Journal:  BMC Oral Health       Date:  2021-03-06       Impact factor: 2.757

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.