Motion artefact reduction of the photoplethysmographic signal in pulse transit time measurement.

J Y A Foo1, S J Wilson, G R Williams, M Harris, D M Cooper.   

Abstract

Motion artefact is a common occurrence that contaminates photoplethysmographic (PPG) measurements. To extract timing information from signals during artefact is challenging. PPG signal is very sensitive to artefacts and can be used in applications like, pulse transit time (PTT) as part of the polysomnographic studies. A correlation cancellation or signal processing approach is implemented with the adaptive cancelling filter concept and a triaxial accelerometry. PPG signals obtained from a Masimo (Reference) pulse oximeter is used as reference to compare with the reconstructed PPG signals. Different hands are used for each PPG source, one stationary while the other involves typical movements during sleep. A second Masimo pulse oximeter is used to register intensity of timing errors on commercial PPG signals. 108 PTT measurements are recorded in three different movements with PTT estimates from unprocessed PPG signals showing 35.51+/-27.42%, Masimo 50.02+/-29.40% and reconstructed 4.32+/-3.59% difference against those from the Reference PPG. The triaxial accelerometry can be used to detect the presence of artefact on PPG signals. This is useful in PTT measurements when signal contaminated with artefacts are required for further analysis, especially after and during arousals in sleep. The suggested filtering model can then reconstruct these corrupted PPG signals.

Entities:  

Mesh:

Year:  2004        PMID: 15712583     DOI: 10.1007/bf03178645

Source DB:  PubMed          Journal:  Australas Phys Eng Sci Med        ISSN: 0158-9938            Impact factor:   1.430


  3 in total

1.  A computational system to optimise noise rejection in photoplethysmography signals during motion or poor perfusion states.

Authors:  Jong Yong A Foo; Stephen J Wilson
Journal:  Med Biol Eng Comput       Date:  2006-03       Impact factor: 2.602

2.  Increasing accuracy of pulse transit time measurements by automated elimination of distorted photoplethysmography waves.

Authors:  Marit H N van Velzen; Arjo J Loeve; Sjoerd P Niehof; Egbert G Mik
Journal:  Med Biol Eng Comput       Date:  2017-03-30       Impact factor: 2.602

Review 3.  Assessing hemodynamics from the photoplethysmogram to gain insights into vascular age: a review from VascAgeNet.

Authors:  Peter H Charlton; Birutė Paliakaitė; Kristjan Pilt; Martin Bachler; Serena Zanelli; Dániel Kulin; John Allen; Magid Hallab; Elisabetta Bianchini; Christopher C Mayer; Dimitrios Terentes-Printzios; Verena Dittrich; Bernhard Hametner; Dave Veerasingam; Dejan Žikić; Vaidotas Marozas
Journal:  Am J Physiol Heart Circ Physiol       Date:  2021-12-24       Impact factor: 4.733